DNA separation with low-viscosity sieving matrix on microfabricated polycarbonate microfluidic chips

被引:0
|
作者
Mei-Ying Ye
Xue-Feng Yin
Zhao-Lun Fang
机构
[1] Zhejiang University,Institute of Microanalytical Systems, Department of Chemistry
来源
关键词
Hot embossing; Polycarbonate; Microchip; DNA; Electrophoresis;
D O I
暂无
中图分类号
学科分类号
摘要
Microfluidic devices have been fabricated on polycarbonate (PC) substrates by use of a hot embossing method using a silicon master template. By adding auxiliary lines around the functional channel on the silicon master, its lifetime was significantly prolonged and the bonding strength of the PC cover plate to the microfluidic chip was greatly improved. More than 300 polycarbonate microfluidic chips have been replicated with the same silicon mold. CE separation of Φ X-174/HaeIII DNA restriction fragments, with high resolution efficiency and good reproducibility, was achieved on these devices using the low-viscosity sieving matrix HPMC-50. Temperature was found to have a significant effect on separation efficiency.
引用
收藏
页码:820 / 827
页数:7
相关论文
共 50 条
  • [21] Kinetics of the phase separation of a low-viscosity liquid supersaturated with gas at the intermediate and later stages
    Slezov, VV
    Abyzov, AS
    Slezova, ZV
    COLLOID JOURNAL, 2005, 67 (01) : 85 - 96
  • [22] Versatile Microfluidic Mixing Platform for High- and Low-Viscosity Liquids via Acoustic and Chemical Microbubbles
    Guan, Yanfang
    Sun, Baichuan
    MICROMACHINES, 2019, 10 (12)
  • [23] Synthesis of low-viscosity hydrophobic magnetic deep eutectic solvent: Selective extraction of DNA
    Peng, Feixia
    Liu, Mei
    Wang, Xuelian
    Ding, Xueqin
    ANALYTICA CHIMICA ACTA, 2021, 1181
  • [24] Purification and preconcentration of genomic DNA from whole cell lysates using photoactivated polycarbonate (PPC) microfluidic chips
    Witek, Malgorzata A.
    Llopis, Shawn D.
    Wheatley, Abigail
    McCarley, Robin L.
    Soper, Steven A.
    NUCLEIC ACIDS RESEARCH, 2006, 34 (10)
  • [25] Separation of oligonucleotides and DNA fragments by capillary electrophoresis in dynamically and permanently coated capillaries, using a copolymer of acrylamide and β-D-glucopyranoside as a new low viscosity matrix with high sieving capacity
    Institute of Biocalysis and Molecular Recognition, CNR, Milano, Italy
    不详
    不详
    Electrophoresis, 18 (3154-3159):
  • [26] Separation of oligonucleotides and DNA fragments by capillary electrophoresis in dynamically and permanently coated capillaries, using a copolymer of acrylamide and β-D-glucopyranoside as a new low viscosity matrix with high sieving capacity
    Chiari, M
    Damin, F
    Melis, A
    Consonni, R
    ELECTROPHORESIS, 1998, 19 (18) : 3154 - 3159
  • [27] Influence of a low-viscosity layer between rigid inclusion and viscous matrix on inclusion rotation and matrix flow: A numerical study
    Marques, FO
    Taborda, R
    Antunes, J
    TECTONOPHYSICS, 2005, 407 (1-2) : 101 - 115
  • [28] Low temperature polysilicon pixel circuits for active-matrix digital microfluidic chips
    Jiang, Shengzhe
    Wang, Dongping
    Ma, Hanbin
    Nathan, Arokia
    Yu, Jun
    DISPLAYS, 2025, 88
  • [29] Designing Low-Viscosity Deep Eutectic Solvents with Multiple Weak-Acidic Groups for Ammonia Separation
    Cao, Yanning
    Zhang, Jiayin
    Ma, Yongde
    Wu, Wenquan
    Huang, Kuan
    Jiang, Lilong
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2021, 9 (21) : 7352 - 7360
  • [30] Separation of DNA by capillary electrophoresis in uncoated silica columns using hydroxypropylmethyl cellulose as the sieving matrix
    Villareal, V
    Zhang, Y
    Zurita, C
    Moran, J
    Silva, I
    Gomez, FA
    ANALYTICAL LETTERS, 2003, 36 (02) : 451 - 463