Improved Aeration Using Perforated Venturi Throat of a Vertical Liquid Jet System with Downcomer

被引:0
|
作者
Ammar Zeghloul
Abdelsalam Al-Sarkhi
Nabil Ghendour
机构
[1] University of Sciences and Technology Houari Boumedien,Faculty of Mechanical and Process Engineering
[2] Polytechnic National School,Department of Mechanical Engineering, Center for Integrated Petroleum Research
[3] King Fahd University of Petroleum and Minerals,undefined
关键词
Venturi; Bubble generation; Bubble size; Water aeration; Downcomer;
D O I
暂无
中图分类号
学科分类号
摘要
The performance of a vertical water jet system with a downcomer for bubble generation has been investigated experimentally. The aeration rate was controlled using perforated throat Venturi with 2, 4, 8, and 16 holes of 1 mm diameter each. Moreover, the bubble plume size and the Sauter mean diameter (SMD) were investigated by image processing obtained from a high-speed camera and a particle sizer algorithm. The void fraction and the entrained gas flow as a function of the liquid flow rate were also studied. A new correlation for the entrained gas flow rate as a function of the Froude number and the ratio of the perforation to throat area is proposed, with high accuracy. The effect of liquid flow on the bubble diameter was analysed for different levels of perforations using probability density function (PDF). The bubble penetration depth was also shown for different perforations at different liquid flow rates. The penetration depth increases significantly with the liquid superficial velocity. The Sauter mean diameter decreases linearly with the liquid superficial velocity as well as the void fraction. The results demonstrate an influence of the number of aspiration holes on the size of the bubbles generated such that the Sauter mean diameter increases with the increasing number of holes in the perforated section. The proposed controlled Venturi flow rate and confined plunging jet system technique is tested in this paper for the first time in the literature and shows considerable potential for controlling water aeration.
引用
收藏
页码:163 / 175
页数:12
相关论文
共 50 条
  • [41] Enhanced Oral Bioavailability and Improved Biological Activities of a Quercetin/Resveratrol Combination Using a Liquid Self-Microemulsifying Drug Delivery System
    Jaisamut, Patcharawalai
    Wanna, Subhaphorn
    Limsuwan, Surasak
    Chusri, Sasitorn
    Wiwattanawongsa, Kamonthip
    Wiwattanapatapee, Ruedeekorn
    PLANTA MEDICA, 2021, 87 (04) : 336 - 346
  • [42] Improved ultra-fast separation of 9 alkylphenones using the Hitachi LaChromUltra High Speed Liquid Chromatography System with advance gradient function
    Jorissen, David
    LC GC NORTH AMERICA, 2008, : 58 - 58
  • [43] Spectrophotometric flow system using vanadomolybdophosphate detection chemistry and a liquid waveguide capillary cell for the determination of phosphate with improved sensitivity in surface and ground water samples
    Neves, M. Sofia A. C.
    Souto, M. Renata S.
    Toth, Ildiko V.
    Victal, Sergio M. A.
    Drumond, M. Claudia
    Rangel, Antonio O. S. S.
    TALANTA, 2008, 77 (02) : 527 - 532
  • [44] AUTOMATED QUANTITATION OF POLYAMINES BY IMPROVED CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A PUMP EQUIPPED WITH A PLUNGER WASHING SYSTEM
    WATANABE, S
    SATO, S
    NAGASE, S
    TOMITA, M
    SAITO, T
    ISHIZU, H
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (03): : 619 - 632
  • [45] Development of a Sustained Release, Liquid Oral in situ Gelling System of Montelukast Sodium with Improved Bioavailability: Equivalence Testing using Earth Mover's Distance
    Mathews, Rashmi
    Rao, B. Prakash
    Abbulu, K.
    Rao, T. Srinivas
    Baby, Beny
    ASIAN JOURNAL OF PHARMACEUTICS, 2019, 13 (02) : 93 - 102
  • [46] Improved Production of Mashua (Tropaeolum tuberosum) Microtubers MAC-3 Morphotype in Liquid Medium Using Temporary Immersion System (TIS-RITA®)
    Pena-Rojas, Gilmar
    Carhuaz-Condori, Roxana
    Andia-Ayme, Vidalina
    Leon, Victor A.
    Herrera-Calderon, Oscar
    AGRICULTURE-BASEL, 2022, 12 (07):
  • [47] Analysis of phosphatidylethanolamine, phosphatidylcholine, and plasmalogen molecular species in food lipids using an improved 2D high-performance liquid chromatography system
    Takahashi, Ryosuke
    Nakaya, Makoto
    Kotaniguchi, Miyako
    Shojo, Aiko
    Kitamura, Shinichi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1077 : 35 - 43
  • [48] Ionic liquid promoted an improved synthesis of 3,4-dihydropyrimidinones using [bmim]BF4 immobilized Cu (II) acetylacetonate as recyclable catalytic system
    Suman L. Jain
    Jomy K. Joseph
    Bir Sain
    Catalysis Letters, 2007, 115 : 52 - 55
  • [49] Ionic liquid promoted an improved synthesis of 3,4-dihydropyrimidinones using [bmim]BF4 immobilized Cu(II) acetylacetonate as recyclable catalytic system
    Jain, Suman L.
    Joseph, Jomy K.
    Sain, Bir
    CATALYSIS LETTERS, 2007, 115 (1-2) : 52 - 55
  • [50] First Dimension Trap-and-Elute Combined with Second Dimension Reversed-Phase Liquid Chromatography Separation Using a Two-Dimensional-Liquid Chromatography-Tandem Mass Spectrometry System for Sensitive Quantification of Human Insulin and Six Insulin Analogs in Plasma: Improved Chromatographic Resolution and Stability Testing
    Sistik, Pavel
    Urinovska, Romana
    Handlosova, Klara
    Handlos, Petr
    Andelova, Katerina
    Jurica, Jan
    Stejskal, David
    JOURNAL OF SEPARATION SCIENCE, 2025, 48 (02)