Effect of Surface Alloying by Silicon on the Corrosion Resistance and Biocompatibility of the Binary NiTi

被引:0
|
作者
S. G. Psakhie
S. N. Meisner
A. I. Lotkov
L. L. Meisner
A. V. Tverdokhlebova
机构
[1] Institute of Strength Physics and Materials Science of the Siberian Branch of the Russian Academy of Sciences - Laboratory of Shape Memory Alloys,
[2] National Research Tomsk State University - Laboratory of Medical Material Science,undefined
关键词
binary NiTi-base alloy; biocompatibility; corrosion resistance; high-dose ion implantation; silicon; surface alloying;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents the study on changes in element and phase compositions in the near-surface layer and on surface topography of the NiTi specimens after the silicon ion-beam treatment. The effect of these parameters of the near-surface layer on corrosion properties in biochemical solutions and biocompatibility with mesenchymal stem cells of rat marrow is studied. Ion-beam surface modification of the specimens was performed by a DIANA-3 implanter (Tomsk, Russia), using single-ion-beam pulses under oil-free pumping and high vacuum (10−4 Pa) conditions in a high-dose ion implantation regime. The fluence made 2 × 1017 cm−2, at an average accelerating voltage of 60 kV, and pulse repetition frequency of 50 Hz. The silicon ion-beam treatment of specimen surfaces is shown to bring about a nearly twofold improvement in the corrosion resistance of the material to attack by aqueous solutions of NaCl (artificial body fluid) and human plasma and a drastic decrease in the nickel concentration after immersion of the specimens into the solutions for ~3400 and ~6000 h, respectively (for the artificial plasma solution, a nearly 20-fold decrease in the Ni concentration is observed). It is shown that improvement of NiTi corrosion resistance after treatment by Si ions occurs mainly due to the formation of two-layer composite coating based on Ti oxides (outer layer) on the NiTi surface and adjacent inner layer of oxides, carbides, and silicides of the NiTi alloy components. Inner layer with high silicon concentration serves as a barrier layer preventing nickel penetration into biomedium. This, in our opinion, is the main reason why the NiTi alloy exhibits no cytotoxic properties after ion modification of its surface and leads to the biocompatibility improvement at the cellular level, respectively.
引用
收藏
页码:2620 / 2629
页数:9
相关论文
共 50 条
  • [21] The corrosion resistance, biocompatibility and antibacterial properties of the silver-doped dicalcium phosphate dihydrate coating on the surface of the additively manufactured NiTi alloy
    Liang, Ping
    Li, Panpan
    Yang, Yanan
    Yang, Kongyuan
    Mao, Chunling
    Chi, Haojie
    Zhang, Jian
    Yu, Zhenglei
    Xu, Zezhou
    Guo, Yunting
    Ren, Luquan
    CERAMICS INTERNATIONAL, 2024, 50 (21) : 43994 - 44007
  • [22] Laser Surface Alloying of Aluminum for Improving Acid Corrosion Resistance
    Jiru W.G.
    Sankar M.R.
    Dixit U.S.
    Journal of The Institution of Engineers (India): Series C, 2019, 100 (03) : 481 - 492
  • [23] Effect of modification of oxide layer on NiTi stent corrosion resistance
    Trépanier, C
    Tabrizian, M
    Yahia, L
    Bilodeau, L
    Piron, DL
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1998, 43 (04): : 433 - 440
  • [24] Effect of modification of oxide layer on NiTi stent corrosion resistance
    GRBB, Biomedical Engineering Institute, Ecl. Polytech. de Montréal, Montreal, Que. H3C 3A7, Canada
    不详
    不详
    J. Biomed. Mater. Res., 4 (433-440):
  • [25] Corrosion Resistance of Surface Treated NiTi Alloy Tested in Artificial Plasma
    Kaczmarek, Marcin
    Kurtyka, Przemyslaw
    INNOVATIONS IN BIOMEDICAL ENGINEERING, 2017, 526 : 17 - 24
  • [26] Graphene enhanced anti-corrosion and biocompatibility of NiTi alloy
    Zhang, Liqiang
    Duan, Yongli
    Gao, Zhenfei
    Ma, Juan
    Liu, Rui
    Liu, Sijin
    Tu, Zhiqiang
    Liu, Yi
    Bai, Chenghao
    Cui, Lishan
    Yang, Fan
    Liu, Jingfu
    Kong, Jing
    Li, Yongfeng
    NANOIMPACT, 2017, 7 : 7 - 14
  • [27] Effect of the deposition temperature on corrosion resistance and biocompatibility of the hydroxyapatite coatings
    Vladescu, A.
    Braic, M.
    Azem, F. Ak
    Titorencu, I.
    Braic, V.
    Pruna, V.
    Kiss, A.
    Parau, A. C.
    Birlik, I.
    APPLIED SURFACE SCIENCE, 2015, 354 : 373 - 379
  • [28] Enhancing biocompatibility and corrosion resistance of Mg implants via surface treatments
    Jo, Ji-Hoon
    Hong, Ji-Yeon
    Shin, Kwang-Seon
    Kim, Hyoun-Ee
    Koh, Young-Hag
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2012, 27 (04) : 469 - 476
  • [29] Corrosion resistance and biocompatibility of titanium surface coated with amorphous tantalum pentoxide
    Sun, Ying-Sui
    Chang, Jean-Heng
    Huang, Her-Hsiung
    THIN SOLID FILMS, 2013, 528 : 130 - 135
  • [30] Effect of surface nanocrystalline for the corrosion fatigue behaviour of NiTi alloys
    Cai, J.
    Wang, Z.
    Zeng, Q. G.
    Liu, J. B.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 123 : 52 - 52