Validity and reliability of simple measurement device to assess the velocity of the barbell during squats

被引:38
|
作者
Lorenzetti S. [1 ]
Lamparter T. [1 ,2 ]
Lüthy F. [2 ]
机构
[1] Institute for Biomechanics, ETH Zurich, Leopold-Ruzicka-Weg 4, Zurich
[2] Swiss Federal Institute of Sport Magglingen (SFISM), Magglingen
关键词
Linear position transducer (LPT); Strength exercises; Training monitoring;
D O I
10.1186/s13104-017-3012-z
中图分类号
学科分类号
摘要
OBJECTIVES: The velocity of a barbell can provide important insights on the performance of athletes during strength training. The aim of this work was to assess the validity and reliably of four simple measurement devices that were compared to 3D motion capture measurements during squatting. Nine participants were assessed when performing 2 × 5 traditional squats with a weight of 70% of the 1 repetition maximum and ballistic squats with a weight of 25 kg. Simultaneously, data was recorded from three linear position transducers (T-FORCE, Tendo Power and GymAware), an accelerometer based system (Myotest) and a 3D motion capture system (Vicon) as the Gold Standard. Correlations between the simple measurement devices and 3D motion capture of the mean and the maximal velocity of the barbell, as well as the time to maximal velocity, were calculated.; RESULTS: The correlations during traditional squats were significant and very high (r = 0.932, 0.990, p < 0.01) and significant and moderate to high (r = 0.552, 0.860, p < 0.01). The Myotest could only be used during the ballistic squats and was less accurate. All the linear position transducers were able to assess squat performance, particularly during traditional squats and especially in terms of mean velocity and time to maximal velocity.
引用
收藏
相关论文
共 50 条
  • [21] Validity and reliability of a new ankle dorsiflexion measurement device
    Gatt, Alfred
    Chockalingam, Nachiappan
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2013, 37 (04) : 289 - 297
  • [22] VALIDITY AND RELIABILITY OF THE PUSH WEARABLE DEVICE TO MEASURE MOVEMENT VELOCITY DURING THE BACK SQUAT EXERCISE
    Balsalobre-Fernandez, Carlos
    Kuzdub, Matt
    Poveda-Ortiz, Pedro
    del Campo-Vecino, Juan
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (07) : 1968 - 1974
  • [23] The Reliability and Validity of Current Technologies for Measuring Barbell Velocity in the Free-Weight Back Squat and Power Clean
    Thompson, Steve W.
    Rogerson, David
    Dorrell, Harry F.
    Ruddock, Alan
    Barnes, Andrew
    SPORTS, 2020, 8 (07)
  • [24] Validity and Reliability of Pulse Wave Velocity Measurement in a Seated Posture
    Kowalsky, Robert J.
    Stoner, Lee
    Perdomo, Sophy
    Taormina, John Michael
    Jones, Melissa
    Credeur, Daniel
    Gibbs, Bethany Barone
    CIRCULATION, 2019, 139
  • [25] Validity of Barbell Velocities Recorded from the GymAware Device during Squat and Bench Press Exercises
    Zangakis, Dylan S.
    Moir, Gavin
    Snyder, Brandon
    Munford, Shawn
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 49 - 50
  • [26] Validity and Reliability of a Commercially-Available Velocity and Power Testing Device
    Askow, Andrew T.
    Stone, Jason D.
    Arndts, Daniel J.
    King, Adam C.
    Goto, Shiho
    Hannon, Joseph P.
    Garrison, J. Craig
    Bothwell, James M.
    Esposito, Phil E.
    Jagim, Andrew R.
    Jones, Margaret T.
    Jennings, Will
    Oliver, Jonathan M.
    SPORTS, 2018, 6 (04):
  • [27] Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device
    Lodge, Clare
    Tobin, Diarmuid
    O'Rourke, Brian
    Thorborg, Kristian
    ARCHIVES OF REHABILITATION RESEARCH AND CLINICAL TRANSLATION, 2020, 2 (01)
  • [28] Validity and reliability of a new in vivo ankle stiffness measurement device
    Zinder, Steven M.
    Granata, Kevin P.
    Padua, Darin A.
    Gansneder, Bruce M.
    JOURNAL OF BIOMECHANICS, 2007, 40 (02) : 463 - 467
  • [29] Reliability And Validity Of A Novel Field Testing Device To Assess Eccentric Hamstring Strength
    Opar, David
    Williams, Morgan
    Piatkowski, Timothy
    Shield, Anthony
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 431 - 431
  • [30] Reliability of Barbell Velocities Recorded from the GymAware Device during Squat and Bench Press Exercises
    Munford, Shawn N.
    Zangakis, Dylan S.
    Moir, Gavin L.
    Snyder, Brandon W.
    Davis, Shala E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 50 - 50