Development of an electrochemical DNA biosensor for detection of specific Mycobacterium tuberculosis sequence based on poly(L-glutamic acid) modified electrode

被引:0
|
作者
MERVE YESIL
SONER DONMEZ
FATMA ARSLAN
机构
[1] Gazi University,Department of Chemistry, Faculty of Science
[2] Mehmet Akif Ersoy University,Bucak School of Health
来源
关键词
Poly(L-glutamic acid); DNA sensor; Mycobacteriumtuberculosis.;
D O I
暂无
中图分类号
学科分类号
摘要
An electrochemical DNA biosensor was developed by avidin-biotin interaction of a biotinylated probe and avidin-attached, poly(L-glutamic) acid coated pencil graphite electrode (PGA/PGE) for detection of specific Mycobacterium tuberculosis DNA sequence. The discrimination of fully complementary hybridization and mismatch hybridization was carried out by electrochemical reduction current of Meldola’s Blue (MDB) in square wave voltammetry (SWV). The calibration graph of the DNA biosensor was linear between 1.5–12.5 nM and the detection limit was calculated as 1.3 nM. The proposed biosensor successfully discriminated short and long oligonucleotides related to DNA sequence of Mycobacterium tuberculosis in optimal condition.
引用
收藏
页码:1823 / 1829
页数:6
相关论文
共 50 条
  • [1] Development of an electrochemical DNA biosensor for detection of specific Mycobacterium tuberculosis sequence based on poly(L-glutamic acid) modified electrode
    Yesil, Merve
    Donmez, Soner
    Arslan, Fatma
    JOURNAL OF CHEMICAL SCIENCES, 2016, 128 (11) : 1823 - 1829
  • [2] ELECTROCHEMICAL DETECTION OF EPINEPHRINE USING AN L-GLUTAMIC ACID FUNCTIONALIZED GRAPHENE MODIFIED ELECTRODE
    Kang, Hongzhe
    Jin, Yan
    Han, Qian
    ANALYTICAL LETTERS, 2014, 47 (09) : 1552 - 1563
  • [3] A Nucleic Acid Biosensor for Detection of Hepatitis C Virus Genotype 1a Using Poly(l-Glutamic Acid)-Modified Electrode
    Donmez, Soner
    Arslan, Fatma
    Arslan, Halit
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2015, 176 (05) : 1431 - 1444
  • [4] A Nucleic Acid Biosensor for Detection of Hepatitis C Virus Genotype 1a Using Poly(l-Glutamic Acid)-Modified Electrode
    Soner Donmez
    Fatma Arslan
    Halit Arslan
    Applied Biochemistry and Biotechnology, 2015, 176 : 1431 - 1444
  • [5] Biosensor for the neurotransmitter L-glutamic acid: Development and characterisation
    Kinsella, M. E.
    Lowry, J. P.
    O'neill, R. D.
    JOURNAL OF NEUROCHEMISTRY, 2007, 102 : 197 - 197
  • [6] Electrochemical biosensor for Mycobacterium tuberculosis DNA detection based on gold nanotubes array electrode platform
    Torati, Ramulu
    Reddy, Venu
    Yoon, Seok Soo
    Kim, CheolGi
    BIOSENSORS & BIOELECTRONICS, 2016, 78 : 483 - 488
  • [7] Simultaneous Electrochemical Determination of Dopamine and Epinephrine with a Silver-Doped Poly(L-Glutamic Acid) Modified Electrode
    Hu, Wenna
    Sun, Dengming
    Ma, Wei
    CHEMIA ANALITYCZNA, 2008, 53 (05): : 703 - 716
  • [8] Designing and fabrication of a novel sensitive electrochemical aptasensor based on poly (L-glutamic acid)/MWCNTs modified glassy carbon electrode for determination of tetracycline
    Benvidi, Ali
    Yazdanparast, Samira
    Rezaeinasab, Masoud
    Tezerjani, Marzieh Dehghan
    Abbasi, Saleheh
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 808 : 311 - 320
  • [9] Electrochemical characterization of deoxyribonucleic acid on aluminum (III)/poly(L-glutamic acid) film and its application for the detection of phosphinothricin acetyltransferase gene-specific sequence
    Zhou, Na
    Yang, Tao
    Zhang, Yongchun
    Jiang, Chen
    Jiao, Kui
    THIN SOLID FILMS, 2009, 518 (01) : 338 - 342
  • [10] Electrochemical biosensor for assessment of the total antioxidant capacity of orange juice beverage based on the immobilizing DNA on a poly L-glutamic acid doped silver hybridized membrane
    Wang, Xueliang
    Jiao, Cuiling
    Yu, Zhangyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 192 : 628 - 633