Reusable voltammetric immunosensor for sCD40L, a biomarker for the acute coronary syndrome, using a glassy carbon electrode modified with a nanocomposite consisting of gold nanoparticles, branched polyethylenimine and carboxylated multiwalled carbon nanotubes

被引:0
|
作者
Jing Wu
Junlin He
Yuchan Zhang
Yilin Zhao
Yazhen Niu
Chao Yu
机构
[1] Chongqing Medical University,College of Pharmacy, Institute of Life Science and School of Public Health
来源
Microchimica Acta | 2017年 / 184卷
关键词
Randle-Sevcik; DPV; Hexacyanoferrate; Acute coronary syndrome; Soluble CD40 ligand;
D O I
暂无
中图分类号
学科分类号
摘要
The authors describe a nanocomposite prepared from gold nanoparticles, branched polyethylenimine and carboxylated multiwalled carbon nanotubes (AuNP/b-PEI/c-MWCNTs), and its application to a highly sensitive electrochemical immunosensor for the soluble CD40 ligand (sCD40L), a biomarker of acute coronary syndrome (ACS). It is known that c-MWCNTs possess a remarkably good electrochemical conductivity that can improve the sensitivity of an immunosensor, but their tendency towards aggregation is an obstacle. The use of b-PEI can substantially decrease the tendency towards aggregation. AuNPs with their large specific surface and good electrical conductivity were used to load the antibody. The nanocomposite was characterized by transmission electron microscopy, atomic force microscopy, energy dispersive spectroscopy, electrochemical impedance spectroscopy, and cyclic voltammetry. When using hexacyanoferrate as an electrochemical probe (best detected at 0.18 V vs. SCE), the electrode displays a linear response in the 10 fg mL−1 to 100 pg mL−1 sCD40L concentration range, and a lower detection limit of 3 fg mL−1. The electrode is regenerable. It was applied to the determination of sCD40L in spiked serum samples, and the results agreed well with an ELISA.
引用
收藏
页码:1837 / 1845
页数:8
相关论文
共 41 条
  • [31] An electrochemical immunosensor for the tumor marker α-fetoprotein using a glassy carbon electrode modified with a poly(5-formylindole), single-wall carbon nanotubes, and coated with gold nanoparticles and antibody
    Lin Zhang
    Chenxi Li
    Dan Zhao
    Tingting Wu
    Guangming Nie
    Microchimica Acta, 2014, 181 : 1601 - 1608
  • [32] Voltammetric paracetamol sensor using a gold electrode made from a digital versatile disc chip and modified with a hybrid material consisting of carbon nanotubes and copper nanoparticles
    Daneshvar, Leili
    Rounaghi, Gholam Hossein
    Tarahomi, Somayeh
    MICROCHIMICA ACTA, 2016, 183 (11) : 3001 - 3007
  • [33] Voltammetric paracetamol sensor using a gold electrode made from a digital versatile disc chip and modified with a hybrid material consisting of carbon nanotubes and copper nanoparticles
    Leili Daneshvar
    Gholam Hossein Rounaghi
    Somayeh Tarahomi
    Microchimica Acta, 2016, 183 : 3001 - 3007
  • [34] Enzyme-based sensing of glucose using a glassy carbon electrode modified with a one-pot synthesized nanocomposite consisting of chitosan, reduced graphene oxide and gold nanoparticles
    Yongkang Ye
    Shun Ding
    Yingwang Ye
    Houchuan Xu
    Xiaodong Cao
    Sheng Liu
    Hanju Sun
    Microchimica Acta, 2015, 182 : 1783 - 1789
  • [35] Enzyme-based sensing of glucose using a glassy carbon electrode modified with a one-pot synthesized nanocomposite consisting of chitosan, reduced graphene oxide and gold nanoparticles
    Ye, Yongkang
    Ding, Shun
    Ye, Yingwang
    Xu, Houchuan
    Cao, Xiaodong
    Liu, Sheng
    Sun, Hanju
    MICROCHIMICA ACTA, 2015, 182 (9-10) : 1783 - 1789
  • [36] Voltammetric aptamer-based switch probes for sensing diclofenac using a glassy carbon electrode modified with a composite prepared from gold nanoparticles, carbon nanotubes and amino-functionalized Fe3O4 nanoparticles
    Azadbakht, Azadeh
    Beirnvand, Shabnam
    MICROCHIMICA ACTA, 2017, 184 (08) : 2825 - 2835
  • [37] Voltammetric aptamer-based switch probes for sensing diclofenac using a glassy carbon electrode modified with a composite prepared from gold nanoparticles, carbon nanotubes and amino-functionalized Fe3O4 nanoparticles
    Azadeh Azadbakht
    Shabnam Beirnvand
    Microchimica Acta, 2017, 184 : 2825 - 2835
  • [38] Comments on: “Voltammetric analysis of epinephrine using glassy carbon electrode modified with nanocomposite prepared from Co-Nd bimetallic nanoparticles, alumina nanoparticles and functionalized multiwalled carbon nanotubes” by Tiwari, Ida et al., DOI: 10.1007/s11356-022-23660-y
    Baththirange Malaka Munasinghe
    Environmental Science and Pollution Research, 2023, 30 : 54248 - 54249
  • [39] Simultaneous voltammetric determination of cadmium(II), lead(II), mercury(II), zinc(II), and copper(II) using a glassy carbon electrode modified with magnetite (Fe3O4) nanoparticles and fluorinated multiwalled carbon nanotubes
    Wenqin Wu
    Mingming Jia
    Zhongzheng Wang
    Wen Zhang
    Qi Zhang
    Guozhen Liu
    Zhaowei Zhang
    Peiwu Li
    Microchimica Acta, 2019, 186
  • [40] Simultaneous voltammetric determination of cadmium(II), lead(II), mercury(II), zinc(II), and copper(II) using a glassy carbon electrode modified with magnetite (Fe3O4) nanoparticles and fluorinated multiwalled carbon nanotubes
    Wu, Wenqin
    Jia, Mingming
    Wang, Zhongzheng
    Zhang, Wen
    Zhang, Qi
    Liu, Guozhen
    Zhang, Zhaowei
    Li, Peiwu
    MICROCHIMICA ACTA, 2019, 186 (02)