Combination of carbon isotope ratio with hydrogen isotope ratio determinations in sports drug testing

被引:0
|
作者
Thomas Piper
Caroline Emery
Andreas Thomas
Martial Saugy
Mario Thevis
机构
[1] German Sport University Cologne,Center for Preventive Doping Research—Institute of Biochemistry
[2] University Center of Legal Medicine,Swiss Laboratory for Doping Analysis
[3] Geneva and Lausanne,undefined
[4] Centre Hospitalier Universitaire Vaudois and University Lausanne,undefined
来源
关键词
Reference population; Carbon isotope ratio; Hydrogen isotope ratio; Doping control; Steroid metabolism;
D O I
暂无
中图分类号
学科分类号
摘要
Carbon isotope ratio (CIR) analysis has been routinely and successfully applied to doping control analysis for many years to uncover the misuse of endogenous steroids such as testosterone. Over the years, several challenges and limitations of this approach became apparent, e.g., the influence of inadequate chromatographic separation on CIR values or the emergence of steroid preparations comprising identical CIRs as endogenous steroids. While the latter has been addressed recently by the implementation of hydrogen isotope ratios (HIR), an improved sample preparation for CIR avoiding co-eluting compounds is presented herein together with newly established reference values of those endogenous steroids being relevant for doping controls. From the fraction of glucuronidated steroids 5β-pregnane-3α,20α-diol, 5α-androst-16-en-3α-ol, 3α-Hydroxy-5β-androstane-11,17-dione, 3α-hydroxy-5α-androstan-17-one (ANDRO), 3α-hydroxy-5β-androstan-17-one (ETIO), 3β-hydroxy-androst-5-en-17-one (DHEA), 5α- and 5β-androstane-3α,17β-diol (5aDIOL and 5bDIOL), 17β-hydroxy-androst-4-en-3-one and 17α-hydroxy-androst-4-en-3-one were included. In addition, sulfate conjugates of ANDRO, ETIO, DHEA, 3β-hydroxy-5α-androstan-17-one plus 17α- and androst-5-ene-3β,17β-diol were considered and analyzed after acidic solvolysis. The results obtained for the reference population encompassing n = 67 males and females confirmed earlier findings regarding factors influencing endogenous CIR. Variations in sample preparation influenced CIR measurements especially for 5aDIOL and 5bDIOL, the most valuable steroidal analytes for the detection of testosterone misuse. Earlier investigations on the HIR of the same reference population enabled the evaluation of combined measurements of CIR and HIR and its usefulness regarding both steroid metabolism studies and doping control analysis. The combination of both stable isotopes would allow for lower reference limits providing the same statistical power and certainty to distinguish between the endo- or exogenous origin of a urinary steroid.
引用
收藏
页码:5455 / 5466
页数:11
相关论文
共 50 条
  • [31] The isotope ratio in petroleum
    Filippova, NS
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1935, 3 (05): : 316 - 316
  • [32] Complementary stable carbon isotope ratio and amount of substance measurements in sports anti-doping
    Cawley, Adam T.
    George, Adrian V.
    [J]. DRUG TESTING AND ANALYSIS, 2012, 4 (12) : 897 - 911
  • [33] Membrane permeation continuous-flow isotope ratio mass spectrometry for on-line carbon isotope ratio determination
    Tremblay, Patrice
    Savard, Martine M.
    Smirnoff, Anna
    Paquin, Real
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (14) : 2213 - 2220
  • [34] Carbon Isotope Ratio Analysis of Steroids by High-Temperature Liquid Chromatography-Isotope Ratio Mass Spectrometry
    Zhang, Lijun
    Thevis, Mario
    Piper, Thomas
    Jochmann, Maik A.
    Wolbert, J. Benjamin
    Kujawinski, Dorothea M.
    Wiese, Steffen
    Teutenberg, Thorsten
    Schmidt, Torsten C.
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (05) : 2297 - 2302
  • [35] Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates
    Moerdijk-Poortvliet, Tanja C. W.
    Schierbeek, Henk
    Houtekamer, Marco
    van Engeland, Tom
    Derrien, Delphine
    Stal, Lucas J.
    Boschker, Henricus T. S.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (13) : 1205 - 1214
  • [36] Carbon isotope ratio mass spectrometry for detection of endogenous steroid use: A testing strategy
    Ahrens, Brian D.
    Butch, Anthony W.
    [J]. DRUG TESTING AND ANALYSIS, 2013, 5 (07) : 534 - 540
  • [37] Distribution of stable carbon isotope ratio in Sargassum plants
    Ishihi, Y
    Yamada, Y
    Ajisaka, T
    Yokoyama, H
    [J]. FISHERIES SCIENCE, 2001, 67 (02) : 367 - 369
  • [38] CARBON ISOTOPE RATIO INTERACTIONS IN A TROPICAL COASTAL LAGOON
    BOTELLO, AV
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 191 : 14 - GEOC
  • [39] A study of adulteration in brazilian honeys by carbon isotope ratio
    de Souza-Kruliski, Cibele Regina
    Ducatti, Carlos
    Venturini Filho, Waldemar Gastoni
    Orsi, Ricardo de Oliveira
    Silva, Evandro Tadeu
    [J]. CIENCIA E AGROTECNOLOGIA, 2010, 34 (02): : 434 - 439
  • [40] THE CARBON-ISOTOPE ABUNDANCE RATIO IN COMET HALLEY
    KLEINE, M
    WYCKOFF, S
    WEHINGER, PA
    PETERSON, BA
    [J]. ASTROPHYSICAL JOURNAL, 1995, 439 (02): : 1021 - 1033