Isotope Ratio Analysis of Lead in Blood and Environmental Samples by Multi-collector Inductively Coupled Plasma Mass Spectrometry

被引:0
|
作者
Mai Takagi
Jun Yoshinaga
Atsushi Tanaka
Haruhiko Seyama
机构
[1] The University of Tokyo,Department of Environmental Studies
[2] National Institute for Environmental Studies,undefined
来源
Analytical Sciences | 2011年 / 27卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
It is widely recognized that lead (Pb) affects children’s cognitive function, even at relatively low blood lead levels (<10 μg dL–1). The determination of the source of Pb in children is essential for effective risk management. The use of multi-collector ICPMS (MC-ICPMS) for isotope ratio measurements of Pb in environmental and biological samples was examined for this purpose. MC-ICPMS with an instrumental mass fractionation correction by Tl allowed accurate isotope ratio measurements of the Pb isotopic reference material NIST SRM 981. However, the presence of matrix elements (Al, Ca, Fe and Na) at more than 10 mg kg–1 in the sample solution significantly deteriorated the accuracy. The separation of Pb from the matrix is necessary for accurate measurements of the isotope ratio of Pb in environmental and biological samples. Bromide-complexation, followed by anion exchange was found to be satisfactory in terms of the recovery of Pb (90 to 104%) and the efficiency of matrix separation. The procedure was applied to a preliminary source analysis of Pb in the blood of Japanese children, and a significant contribution of indoor dust was demonstrated.
引用
收藏
页码:29 / 35
页数:6
相关论文
共 50 条
  • [31] Ultra-trace determination of plutonium in marine samples using multi-collector inductively coupled plasma mass spectrometry
    Lindahl, Patric
    Keith-Roach, Miranda
    Worsfold, Paul
    Choi, Min-Seok
    Shin, Hyung-Seon
    Lee, Sang-Hoon
    ANALYTICA CHIMICA ACTA, 2010, 671 (1-2) : 61 - 69
  • [32] Determination of Stable Silicon Isotopes Using Multi-Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang An-Yu
    Zhang Jing
    Zhang Rui-Feng
    Xue Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (09) : 1353 - 1358
  • [33] Determination of Eu isotopic ratio by multi-collector inductively coupled plasma mass spectrometry using a Sm internal standard
    Lee, Seung-Gu
    Tanaka, Tsuyoshi
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 156 : 42 - 50
  • [34] Revised exponential model for mass bias correction using an internal standard for isotope abundance ratio measurements by multi-collector inductively coupled plasma mass spectrometry
    Baxter, DC
    Rodushkin, I
    Engström, E
    Malinovsky, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (04) : 427 - 430
  • [35] Measurements of lead isotope ratio in cement by inductively coupled plasma mass spectrometry
    Chen, JM
    Tan, MG
    Lu, WW
    Li, YL
    Zhang, GL
    Li, Y
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (07) : 943 - 946
  • [36] Recent advances in method development and application of multi-collector inductively coupled plasma mass spectrometry
    Zhang Luyao
    Chen Zigu
    Yang Xuezhi
    Lu Dawei
    Liu Qian
    Jiang Guibin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (01) : 4 - 9
  • [37] Lead isotope analysis of archaeological metals by multiple-collector inductively coupled plasma mass spectrometry
    Baker, J
    Stos, S
    Waight, T
    ARCHAEOMETRY, 2006, 48 : 45 - 56
  • [38] Development of an indigenous multi-collector inductively coupled plasma mass spectrometer
    Yogesh Kumar
    R. K. Bhatia
    E. Ravisankar
    Prakash Abichandani
    T. K. Saha
    V. Nataraju
    R. K. Vatsa
    Indian Journal of Physics, 2024, 98 : 2559 - 2570
  • [39] Rapid determination of 237Np in soil samples by multi-collector inductively-coupled plasma mass spectrometry and gamma spectrometry
    Xiaowei Yi
    Yanmei Shi
    Jiang Xu
    Xiaobing He
    Haitao Zhang
    Jianfeng Lin
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 298 : 1757 - 1761
  • [40] Rapid determination of 237Np in soil samples by multi-collector inductively-coupled plasma mass spectrometry and gamma spectrometry
    Yi, Xiaowei
    Shi, Yanmei
    Xu, Jiang
    He, Xiaobing
    Zhang, Haitao
    Lin, Jianfeng
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 298 (03) : 1757 - 1761