Ambulatory long-term pH monitoring in pigs

被引:0
|
作者
K. A. Gawad
R. Wachowiak
C. Rempf
W. J. Tiefenbacher
T. Strate
E. G. Achilles
C. Blöchle
J. R. Izbicki
机构
[1] University Hospital Hamburg–Eppendorf,Department of Surgery
[2] University of Hamburg,undefined
[3] Martinstr. 52,undefined
[4] D-20246 Hamburg,undefined
关键词
Gastroesophageal Reflux; Achalasia; Lower Esophageal Sphincter; Acid Reflux; Antireflux Procedure;
D O I
暂无
中图分类号
学科分类号
摘要
Background: pH monitoring has been established as the “gold standard” in the diagnosis of gastroesophageal reflux. Evaluation of experimental antireflux therapy should therefore also include this technique, but a suitable technique in an experimental model did not exist so far. The aim of our study was to establish a reliable method for the evaluation of an experimental reflux model in pigs. Methods: A total of 33 German Landrace pigs with an average body weight of 56 (50.2–67.2) kg were included. pH monitoring was performed before and after open cardiomyotomy in each animal. All manipulations were performed under general anesthesia. After manometric localization of the gastroesophageal high-pressure zone, a standard pH probe was inserted into the pharynx through a small needle-punctured canal on the side of the animal’s snout and placed under endoscopic guidance with the proximal sensor 3 cm above the lower esophageal sphincter (LES) and the distal sensor in the stomach for reference. The harness to carry the pH recorder on the animal’s back consisted of a modified belly strap that enabled the animal to move around without limitation. For analysis the same threshold levels were defined as in humans. Gastroesophageal reflux was induced by cardiomyotomy. Results: The placement of the standard pH probe was possible in all cases. Inserting the probe on the side of the snout left the animals free to nuzzle, which complies with the normal habits of pigs, without breaking the probes and without being compromised in their natural behavior. Repeated punctures for multiple measurements were easily feasible. We performed up to three examinations in each individual animal. Recording was performed for 48 h. A mean number of 67.3 (±9.7) acidic refluxes were registered. The mean number of long acidic refluxes was 3.2 (±0.75). For an average total time of 75.5 (±14.3) min the pH was below 4 accounting for a fraction time pH below 4 of 3.5% (±0.68%). Following cardiomyotomy the number of acidic refluxes increased significantly to 166.1 (±21.8) and the number of long refluxes to 17.74 (±3.35). The total time of pH below 4 increased to 371.3 (±62) min so that the fraction time pH below 4 was 14.5% (p = 0.0006). Conclusion: pH monitoring should be mandatory in any investigation of antireflux therapy. Our method is easy and secure to perform. It is suitable for other gastrointestinal investigations (Bilitec, long-term manometry) that could be carried out using the same technique. The described data represent the basis for other investigations of experimental antireflux therapy.
引用
收藏
页码:1556 / 1560
页数:4
相关论文
共 50 条
  • [21] Long-term gastrointestinal monitoring (pH measurements and motility)
    Sass, NL
    Koop, H
    [J]. INTERNIST, 1997, 38 (09): : 811 - 819
  • [22] New method for long-term monitoring of intragastric pH
    Shouko Ono
    Mototsugu Kato
    Yuji Ono
    Masahiro Asaka
    [J]. World Journal of Gastroenterology, 2007, (47) : 6410 - 6413
  • [23] New method for long-term monitoring of intragastric pH
    Ono, Shouko
    Kato, Mototsugu
    Ono, Yuji
    Asaka, Masahiro
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2007, 13 (47) : 6410 - 6413
  • [24] LONG-TERM PH MONITORING IN THE EVALUATION OF GASTROESOPHAGEAL REFLUX
    SCOTT, LD
    [J]. TEXAS MEDICINE, 1986, 82 (02) : 32 - 36
  • [25] The development of long - Term ambulatory pH monitoring system and its clinical application
    Kong, FL
    Pan, GT
    Xia, ZW
    Chai, HJ
    Lin, SR
    Huang, XM
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1914 - 1916
  • [26] LONG-TERM AMBULATORY GASTRIC PH MONITORING - VALIDATION OF A NEW METHOD AND EFFECT OF H2-ANTAGONISTS
    FIMMEL, CJ
    ETIENNE, A
    CILLUFFO, T
    VONRITTER, C
    GASSER, T
    REY, JP
    CARADONNAMOSCATELLI, P
    SABBATINI, F
    PACE, F
    BUHLER, HW
    BAUERFEIND, P
    BLUM, AL
    [J]. GASTROENTEROLOGY, 1985, 88 (06) : 1842 - 1851
  • [27] AMBULATORY LONG-TERM BLOOD-PRESSURE MONITORING - WHAT IS NORMAL
    BAUMGART, P
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1991, 80 : 29 - 32
  • [28] Clinical Characteristics of Patients with Atrial Fibrillation on Long-term Ambulatory Monitoring
    Carlson, Steven
    Saxon, Leslie
    Doshi, Rahul
    Shinbane, Jerold
    Chang, Philip
    Eisenberg, Evann
    [J]. JOURNAL OF CARDIAC FAILURE, 2014, 20 (08) : S92 - S92
  • [29] Ambulatory monitoring uncorrected for placebo overestimates long-term antihypertensive action
    Staessen, JA
    Thijs, L
    Bieniaszewski, L
    OBrien, ET
    Palatini, P
    Davidson, C
    Dobovisek, J
    Jaaskivi, M
    Laks, T
    Lehtonen, A
    Vanhanen, H
    Webster, J
    Fagard, R
    [J]. HYPERTENSION, 1996, 27 (03) : 414 - 420
  • [30] A DEVICE FOR LONG-TERM AMBULATORY MONITORING IN TRANS-TIBIAL AMPUTEES
    STAM, HJ
    EIJSKOOT, F
    BUSSMANN, JBJ
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1995, 19 (01) : 53 - 55