Two immunoassay formats for fully automated CRP detection in human serum

被引:0
|
作者
Christiane Albrecht
Nina Kaeppel
Guenter Gauglitz
机构
[1] Eberhard-Karls-University of Tuebingen,Institute of Physical and Theoretical Chemistry (IPTC)
来源
Analytical and Bioanalytical Chemistry | 2008年 / 391卷
关键词
Optical immunosensor; River analyser (RIANA); C-reactive protein (CRP); High-sensitivity CRP (hsCRP); Healthcare; TIRF;
D O I
暂无
中图分类号
学科分类号
摘要
Immunoassays are a proven approach towards fast, sensitive, cost-effective and easy-to-use analytical systems which are able to measure a variety of interesting analytes, especially in medical diagnostics. Herein, we report two assay formats, binding inhibition and sandwich assay format, for detection of C-reactive protein (CRP) in human serum. Both assays were characterised and compared with respect to their suitability and adaption into a complete sensor system. An automated, optical biosensor system, based on evanescent field technology, was used to carry out a full threefold calibration in each case. Owing to the resulting working ranges, 0.044–2.9 mg L−1 and 0.13–22.9 mg L−1, respectively, the assays qualify for use in detecting high-sensitivity CRP (C-reactive protein).
引用
收藏
相关论文
共 50 条
  • [21] Concordance of four commercial enzyme immunoassay and three immunoblot formats for the detection of Lyme borreliosis antibodies in human serum: the two-tier approach remains
    Dickeson, David J.
    Chen, Sharon C-A.
    Sintchenko, Vitali G.
    PATHOLOGY, 2016, 48 (03) : 251 - 256
  • [22] Development and comparison of two immunoassay formats for rapid detection of botulinum neurotoxin type A
    Attree, Olivier
    Guglielmo-Viret, Valerie
    Gros, Valerie
    Thullier, Philippe
    JOURNAL OF IMMUNOLOGICAL METHODS, 2007, 325 (1-2) : 78 - 87
  • [23] Detection of κ and λ light chain monoclonal proteins in human serum:: Automated immunoassay versus immunofixation electrophoresis
    Jaskowski, TD
    Litwin, CM
    Hill, HR
    CLINICAL AND VACCINE IMMUNOLOGY, 2006, 13 (02) : 277 - 280
  • [24] A FULLY AUTOMATED IMMUNOASSAY FOR THYROXINE EVALUATED
    HARMOINEN, A
    VUORINEN, P
    JOKELA, H
    CLINICAL CHEMISTRY, 1986, 32 (10) : 1987 - 1987
  • [25] AN EVALUATION OF A FULLY AUTOMATED IMMUNOASSAY OF THYROXINE
    VUORINEN, P
    HARMOINEN, A
    JOKELA, H
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1986, 46 : 134 - 134
  • [26] FULLY AUTOMATED HUMAN CHORIONIC-GONADOTROPIN (HCG) IMMUNOASSAY USING ELECSYS, A NEW ELECTROCHEMILUMINESCENCE DETECTION SYSTEM
    KRAISS, S
    NEUMANN, U
    SCHMIDT, G
    LENZ, H
    FRANKEN, N
    CLINICAL CHEMISTRY, 1995, 41 (06) : S53 - S53
  • [27] TECHNICON ALPHA-FETOPROTEIN - A FULLY AUTOMATED ENZYME-IMMUNOASSAY FOR THE DETERMINATION OF ALPHA-FETOPROTEIN IN HUMAN SERUM
    AYANOGLU, G
    GARRETT, D
    POURFARZANEH, M
    DELLAPUCA, R
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1058 - 1058
  • [28] Evaluation of two fully automated immunoassay based tests for the measurement of 1α, 25-dihydroxyvitamin D in human serum and comparison with LC-MS/MS
    Spanaus, Katharina
    von Eckardstein, Arnold
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (09) : 1305 - 1314
  • [29] Fully automated immunoassay for quantitative determination of FXIII
    Kappel, A.
    Stephan, S.
    Duwe, C.
    Pechmann, L.
    Althaus, H.
    Ehm, M.
    Fischer, B.
    Hahn, M.
    Schwarz, H.
    Vitzthum, F.
    HAMOSTASEOLOGIE, 2011, 31 (02): : 105 - 110
  • [30] Aptamer-antibody on-chip sandwich immunoassay for detection of CRP in spiked serum
    Pultar, Johanna
    Sauer, Ursula
    Domnanich, Patrick
    Preininger, Claudia
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1456 - 1461