Is contrast-enhanced cardiac magnetic resonance imaging at 3 T superior to 1.5 T for detection of coronary artery disease?

被引:0
|
作者
Thomas Walcher
Katharina Ikuye
Wolfgang Rottbauer
Jochen Wöhrle
Peter Bernhardt
机构
[1] University of Ulm,Department of Internal Medicine II
关键词
3 Tesla; Cardiac magnetic resonance imaging; Coronary disease; Adenosine perfusion;
D O I
暂无
中图分类号
学科分类号
摘要
The aim is to compare a compiled clinical routine cardiac magnetic resonance (CMR) imaging protocol performed at both 1.5 and 3 T in patients with suspected coronary artery disease (CAD) undergoing coronary X-ray angiography. CMR including adenosine perfusion and late gadolinium enhancement (LGE) at 1.5 T has been established for noninvasive detection of relevant CAD. However, little is known about the potential advantages of 3 T to detect CAD. Fifty-two evaluable patients (62.3 ± 10.2 years) were included into the study. All patients were scanned at both 1.5 and 3 T including adenosine stress and rest perfusion, and LGE imaging. CMR images were analyzed by two blinded readers in consensus. X-Ray angiography served as the reference method. A significant CAD was diagnosed by quantitative coronary analysis. Diagnostic accuracy of the combined analysis of perfusion and LGE imaging yielded better values at 1.5 and 3 T than the analysis of perfusion images alone. Specificity and sensitivity at 3 T was superior to 1.5 T in detecting coronary stenoses ≥50 % (90 vs. 75 % and 84.4 vs. 75 %) and ≥70 % (88 vs. 80 % and 96.3 vs. 88.9 %). This study showed that CMR at 3 T in a routine clinical setting is superior to 1.5 T in detection of significant CAD. 3 T might become the preferred CMR field strength for evaluation of CAD in clinical practice.
引用
收藏
页码:355 / 361
页数:6
相关论文
共 50 条
  • [41] Improving Bladder Cancer Imaging Using 3-T Functional Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Nguyen, Huyen T.
    Pohar, Kamal S.
    Jia, Guang
    Shah, Zarine K.
    Mortazavi, Amir
    Zynger, Debra L.
    Wei, Lai
    Clark, Daniel
    Yang, Xiangyu
    Knopp, Michael V.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (06) : 390 - 395
  • [42] Diagnosis of acute myocarditis by contrast-enhanced cardiac magnetic resonance imaging
    Subinas, A
    Rilo, I
    Lekuona, I
    Velasco, S
    Larena, JA
    Laraudogoitia, E
    REVISTA ESPANOLA DE CARDIOLOGIA, 2005, 58 (06): : 753 - 755
  • [43] Redefinition of uremic cardiomyopathy by contrast-enhanced cardiac magnetic resonance imaging
    Mark, P. B.
    Johnston, N.
    Groenning, B. A.
    Foster, J. E.
    Blyth, K. G.
    Martin, T. N.
    Steedman, T.
    Dargie, H. J.
    Jardine, A. G.
    KIDNEY INTERNATIONAL, 2006, 69 (10) : 1839 - 1845
  • [44] CONTRAST-ENHANCED MAGNETIC-RESONANCE IMAGING OF CARDIAC TUMORS IN CHILDREN
    NIWA, K
    TASHIMA, K
    TERAI, M
    OKAJIMA, Y
    NAKAJIMA, H
    AMERICAN HEART JOURNAL, 1989, 118 (02) : 424 - 425
  • [45] Radiofrequency heating of retained cardiac leads during magnetic resonance imaging at 1.5 T and 3 T
    Nguyen, Bach T.
    Bhusal, Bhumi
    Fawcett, Kate
    Golestanirad, Laleh
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4986 - 4989
  • [46] Additional value of contrast-enhanced cardiac magnetic resonance imaging for patients with coronary artery disease and ejection fraction over 35% presenting with unexplained syncope
    Outteryck, F.
    Boule, S.
    Pontana, F.
    Longere, B.
    Coisne, A.
    Ninni, S.
    Drumez, E.
    Brigadeau, F.
    Marquie, C.
    Klug, D.
    Jardin, M. Remy
    Lacroix, D.
    EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 : 578 - 578
  • [47] Cardiovascular magnetic resonance perfusion imaging at 3 Tesla for the detection of coronary artery disease: A comparison with 1.5 Tesla
    Cheng, A.
    Pegg, T.
    Karamitsos, T.
    Robson, M.
    Searle, N.
    Jerosch-Herold, M.
    Choudhury, R.
    Banning, A.
    Selvanayagam, J.
    HEART, 2007, 93 : A21 - A21
  • [48] Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0 T - Comparison with steady-state free precession technique at 1.5 T
    Liu, Xin
    Bi, Xiaoming
    Huang, Jie
    Jerecic, Renate
    Carr, James
    Li, Debiao
    INVESTIGATIVE RADIOLOGY, 2008, 43 (09) : 663 - 668
  • [49] Contrast-enhanced hepatic magnetic resonance angiography at 3 T: Does parallel imaging improve image quality?
    Ho, Lisa M.
    Merkle, Elmar M.
    Paulson, Erik K.
    Dale, Brian M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (02) : 177 - 180
  • [50] Contrast-enhanced FLAIR Versus Contrast-enhanced T1-Weighted Sequence of Magnetic Resonance Imaging for the Evaluation of Leptomeningeal Disease: Which one is Better?
    Tepe, Savas
    NOROPSIKIYATRI ARSIVI-ARCHIVES OF NEUROPSYCHIATRY, 2012, 49 (02): : 108 - 113