Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan®

被引:0
|
作者
Hirotoshi Ebinuma
Hidetsugu Saito
Mina Komuta
Keisuke Ojiro
Kanji Wakabayashi
Shingo Usui
Po-sung Chu
Rumiko Umeda
Yuka Ishibashi
Tetsurou Takayama
Masahiro Kikuchi
Nobuhiro Nakamoto
Yoshiyuki Yamagishi
Takanori Kanai
Kiyoshi Ohkuma
Michiie Sakamoto
Toshifumi Hibi
机构
[1] Keio University,Division of Gastroenterology and Hepatology, Department of Internal Medicine, School of Medicine
[2] Keio University,Department of Internal Medicine, School of Medicine and Faculty of Pharmacy
[3] Keio University,Department of Pathology, School of Medicine
[4] Keio University,Department of Diagnostic Radiology, School of Medicine
来源
关键词
Transient elastography; Acoustic radiation force impulse; Liver stiffness; Non-invasive; Fibrosis;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1238 / 1248
页数:10
相关论文
共 50 条
  • [21] Liver Fibrosis: Noninvasive Assessment with Acoustic Radiation Force Impulse Elastography-Comparison with FibroScan M and XL Probes and FibroTest in Patients with Chronic Liver Disease
    Cassinotto, Christophe
    Lapuyade, Bruno
    Ait-Ali, Ania
    Vergniol, Julien
    Gaye, Delphine
    Foucher, Juliette
    Bailacq-Auder, Claire
    Chermak, Faiza
    Le Bail, Brigitte
    de Ledinghen, Victor
    RADIOLOGY, 2013, 269 (01) : 283 - 292
  • [22] The Acoustic Radiation Force Impulse Elastography Evaluation of Liver Fibrosis in Posttransplantation Dysfunction of Living Donor Liver Transplantation
    Liao, C. C.
    Chen, T. Y.
    Tsang, L. C.
    Ou, S. Y.
    Yu, C. Y.
    Hsu, H. W.
    Cheng, Y. F.
    Chiu, K. W.
    Eng, H. L.
    Chen, C. L.
    Huang, T. L.
    TRANSPLANTATION PROCEEDINGS, 2014, 46 (03) : 876 - 879
  • [23] Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography
    Friedrich-Rust, Mireen
    Wunder, Katrin
    Kriener, Susanne
    Sotoudeh, Fariba
    Richter, Swantje
    Bojunga, Joerg
    Herrmann, Eva
    Poynard, Thierry
    Dietrich, Christoph F.
    Vermehren, Johannes
    Zeuzem, Stefan
    Sarrazin, Christoph
    RADIOLOGY, 2009, 252 (02) : 595 - 604
  • [24] NON-INVASIVE EVALUATION OF LIVER FIBROSIS: 2-D SHEAR WAVE ELASTOGRAPHY, TRANSIENT ELASTOGRAPHY OR ACOUSTIC RADIATION FORCE IMPULSE IMAGING?
    Ozturker, Coskun
    Karagoz, Ergenekon
    Incedayi, Mehmet
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (12): : 3052 - 3052
  • [25] Evaluation of acoustic radiation force impulse elastography for fibrosis staging of chronic liver disease: a pilot study
    Takahashi, Hirokazu
    Ono, Naofumi
    Eguchi, Yuichiro
    Eguchi, Takahisa
    Kitajima, Yoichiro
    Kawaguchi, Yasunori
    Nakashita, Shunya
    Ozaki, Iwata
    Mizuta, Toshihiko
    Toda, Shuji
    Kudo, Sho
    Miyoshi, Atsushi
    Miyazaki, Kohji
    Fujimoto, Kazuma
    LIVER INTERNATIONAL, 2010, 30 (04) : 538 - 545
  • [26] Evaluation of Acoustic Radiation Force Impulse Imaging (ARFI) for the Determination of Liver Stiffness Using Transient Elastography as a Reference in Children
    Sagir, A.
    Ney, D.
    Oh, J.
    Pandey, S.
    Kircheis, G.
    Mayatepek, E.
    Haeussinger, D.
    ULTRASOUND INTERNATIONAL OPEN, 2015, 1 (01) : E2 - E7
  • [27] COMPARISON OF TRANSIENT ELASTOGRAPHY (TE) AND ACOUSTIC RADIATION FORCE IMPULSE (ARFI) FOR NONINVASIVE STAGING OF LIVER FIBROSIS IN PATIENTS WITH CHRONIC HEPATITIS C
    Calvaruso, Vincenza
    Rizzo, Leonardo
    Cacopardo, Bruno
    Alessi, Nicola
    Attanasio, Massimo
    Petta, Salvatore
    Fatuzzo, Filippo
    Montineri, Arturo
    Mazzola, Alessandra
    Di Marco, Vito
    Craxi, Antonio
    Comma, Calogero
    HEPATOLOGY, 2010, 52 (04) : 1237A - 1237A
  • [28] Comparison of Transient Elastography and Acoustic Radiation Force Impulse for Non-Invasive Staging of Liver Fibrosis in Patients With Chronic Hepatitis C
    Rizzo, L.
    Calvaruso, Vincenza
    Cacopardo, B.
    Alessi, N.
    Attanasio, M.
    Petta, S.
    Fatuzzo, F.
    Montineri, A.
    Mazzola, A.
    L'abbate, L.
    Nunnari, G.
    Bronte, F.
    Di Marco, V.
    Craxi, A.
    Camma, C.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2011, 106 (12): : 2112 - 2120
  • [29] ASSESSMENT OF LIVER FIBROSIS WITH 2-D SHEAR WAVE ELASTOGRAPHY IN COMPARISON TO TRANSIENT ELASTOGRAPHY AND ACOUSTIC RADIATION FORCE IMPULSE IMAGING IN PATIENTS WITH CHRONIC LIVER DISEASE
    Gerber, Ludmila
    Kasper, Daniela
    Fitting, Daniel
    Knop, Viola
    Vermehren, Annika
    Sprinzl, Kathrin
    Hansmann, Martin L.
    Herrmann, Eva
    Bojunga, Joerg
    Albert, Joerg
    Sarrazin, Christoph
    Zeuzem, Stefan
    Friedrich-Rust, Mireen
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (09): : 2350 - 2359
  • [30] Can acoustic radiation force impulse elastography be a substitute for liver biopsy in predicting liver fibrosis?
    Jain, V.
    Dixit, R.
    Chowdhury, V.
    Puri, A. S.
    Gondal, R.
    CLINICAL RADIOLOGY, 2016, 71 (09) : 869 - 875