The acute effect of stenting with the nitinol self-expanding coil stent: preliminary experience

被引:0
|
作者
Ariel Roguin
Rafael Beyar
机构
[1] Technion-Israel Institute of Technology,Division of Interventional Cardiology, Rambam Medical Center and the Heart System Research Center
关键词
angioplasty; coronary stents; nitinol; recoil;
D O I
暂无
中图分类号
学科分类号
摘要
Background. The acute angiographic results with the self-expanding nitinol stent have not been reported. We aim to provide angiographic data of the effect of self expansion and balloon assistance on the results. This is analyzed with respect to stent gain, arterial- and stent-recoil. Methods and Results. The self-expanding nitinol coil stent is inherently different than balloon-expandable stents in its mechanism of deployment and the way that radial arterial expansion is achieved. Between January 1995 and June 1996, 86 stents were deployed in 64 patients undergoing elective angioplasty at the Rambam Medical Center, Haifa, Israel. The stent deployment procedure involved stent release assisted by high pressure balloon dilatation. The baseline, post-balloon, post-stenting and post-stent-dilatation characteristics were recorded with similar views, digitized to a PC and analyzed by image processing software. Using computerized analysis, arterial- and stent-recoil and stent gain were calculated for the average stented segment lesion (0.48 ± 0.42, 0.22 ± 0.37, 0.28 ± 0.37, respectively). Balloon angioplasty increased the minimal luminal diameter from 1.07 ± 0.73 mm at baseline, to 2.24 ± 0.57 mm; stent deployment further increased the diameter to 2.63 ± 0.48 mm, and within-stent balloon dilatation to 2.96 ± 0.62 mm. Conclusions. The self-expanding nitinol stent exerts its effect on both the MLD and the average stented diameter through its intrinsic radial force aided by post-deployment within-stent balloon dilatation. A significant correlation was found between stent gain and arterial recoil (slope = 0.59, r = 0.68, p<0.001) but not with stent-artery recoil. Therefore, with the negligible effect of stent recoil, the acute benefit of the nitinol stent is directly proportional to arterial recoil, a feature which is also common to balloon-expandable stents.
引用
收藏
页码:441 / 450
页数:9
相关论文
共 50 条
  • [21] Preliminary experience with the use of self-expanding stent as a thrombectomy device in ischemic stroke
    Cohen, Jose E.
    Gomori, John M.
    Leker, Ronen R.
    Eichel, Roni
    Arkadir, David
    Itshayek, Eyal
    NEUROLOGICAL RESEARCH, 2011, 33 (04) : 439 - 443
  • [22] Self-expanding nitinol-stent for palliation of obstructing rectosigmoid malignancies
    Furtwanger, A
    Sontheimer, J
    Ruckauer, KD
    GASTROENTEROLOGY, 1996, 110 (04) : A514 - A514
  • [23] SYMPTOMATIC INTRACRANIAL ARTERIAL STENOSIS TREATMENT WITH SELF-EXPANDING NITINOL STENT
    Balboa Arregui, O.
    Pumar Cebreiro, J. M.
    Vazquez Herrero, F.
    Tijerin Bueno, M.
    Magadan Alvarez, V.
    Castineira Mourenza, J. A.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 6 - 6
  • [24] Initial clinical experience with a new self-expanding nitinol stent for the treatment of intracranial cerebral aneurysms: The Cordis Enterprise stent
    Higashida, RT
    Halbach, VV
    Dowd, CF
    Juravsky, L
    Meagher, S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (07) : 1751 - 1756
  • [25] Self-expanding metal stents for malignant esophagogastric obstruction: Experience with a new design covered nitinol stent
    Keller, Ralf
    Flieger, Dimitri
    Fischbach, Wolfgang
    Christl, Stefan Ulrich
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2007, 16 (03) : 239 - 243
  • [26] Nitinol coil esophageal prosthesis: Advantages of removable self-expanding metallic stents
    Axelrad, AM
    Fleischer, DE
    Gomes, M
    GASTROINTESTINAL ENDOSCOPY, 1996, 43 (02) : 155 - 160
  • [27] In vitro testing of a nitinol self-expanding stent made to fit the carotid bifurcation
    Martin, J
    Frid, N
    Gailloud, P
    Fumex, I
    Amor, M
    Ruefenacht, DA
    RADIOLOGY, 1998, 209P : 473 - 473
  • [28] MALIGNANT DUODENAL STENOSIS - PALLIATION WITH PERORAL IMPLANTATION OF A SELF-EXPANDING NITINOL STENT
    STRECKER, EP
    BOOS, I
    HUSFELDT, KJ
    RADIOLOGY, 1995, 196 (02) : 349 - 351
  • [29] Nanomanufactured nitinol self-expanding stent graft in a carotid system in a porcine model
    Bailey, SR
    Sprague, E
    Boyle, C
    Velez, L
    Polan, J
    Palmaz, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 39A - 39A
  • [30] Incidence and clinical implications of stent fractures of the Xpert self-expanding nitinol stent in infrainguinal arteries
    Keo, H. H.
    Kickuth, R.
    Diehm, N.
    Baumgartner, I.
    Do, Dai-Do
    VASA-JOURNAL OF VASCULAR DISEASES, 2009, 38 (01): : 47 - 52