Fan beam CT image synthesis from cone beam CT image using nested residual UNet based conditional generative adversarial network

被引:0
|
作者
Jiffy Joseph
Ivan Biji
Naveen Babu
P. N. Pournami
P. B. Jayaraj
Niyas Puzhakkal
Christy Sabu
Vedkumar Patel
机构
[1] National Institute of Technology Calicut,Computer science and Engineering Department
[2] MVR Cancer Centre & Research Institute,Department of Medical Physics
来源
Physical and Engineering Sciences in Medicine | 2023年 / 46卷
关键词
Conditional generative adversarial network; Cone beam CT; Fan beam CT; Image synthesis;
D O I
暂无
中图分类号
学科分类号
摘要
A radiotherapy technique called Image-Guided Radiation Therapy adopts frequent imaging throughout a treatment session. Fan Beam Computed Tomography (FBCT) based planning followed by Cone Beam Computed Tomography (CBCT) based radiation delivery drastically improved the treatment accuracy. Furtherance in terms of radiation exposure and cost can be achieved if FBCT could be replaced with CBCT. This paper proposes a Conditional Generative Adversarial Network (CGAN) for CBCT-to-FBCT synthesis. Specifically, a new architecture called Nested Residual UNet (NR-UNet) is introduced as the generator of the CGAN. A composite loss function, which comprises adversarial loss, Mean Squared Error (MSE), and Gradient Difference Loss (GDL), is used with the generator. The CGAN utilises the inter-slice dependency in the input by taking three consecutive CBCT slices to generate an FBCT slice. The model is trained using Head-and-Neck (H&N) FBCT-CBCT images of 53 cancer patients. The synthetic images exhibited a Peak Signal-to-Noise Ratio of 34.04±0.93 dB, Structural Similarity Index Measure of 0.9751±0.001 and a Mean Absolute Error of 14.81±4.70 HU. On average, the proposed model guarantees an improvement in Contrast-to-Noise Ratio four times better than the input CBCT images. The model also minimised the MSE and alleviated blurriness. Compared to the CBCT-based plan, the synthetic image results in a treatment plan closer to the FBCT-based plan. The three-slice to single-slice translation captures the three-dimensional contextual information in the input. Besides, it withstands the computational complexity associated with a three-dimensional image synthesis model. Furthermore, the results demonstrate that the proposed model is superior to the state-of-the-art methods.
引用
收藏
页码:703 / 717
页数:14
相关论文
共 50 条
  • [31] SAR image synthesis based on conditional generative adversarial networks
    Wang, Jianyu
    Li, Jingwen
    Sun, Bing
    Zuo, Zhixiong
    JOURNAL OF ENGINEERING-JOE, 2019, 2019 (21): : 8093 - 8097
  • [32] Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom
    Bamba, J.
    Araki, K.
    Endo, A.
    Okano, T.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (08)
  • [33] Generating synthetic CT from low-dose cone-beam CT by using generative adversarial networks for adaptive radiotherapy
    Gao, Liugang
    Xie, Kai
    Wu, Xiaojin
    Lu, Zhengda
    Li, Chunying
    Sun, Jiawei
    Lin, Tao
    Sui, Jianfeng
    Ni, Xinye
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [34] Generating synthetic CT from low-dose cone-beam CT by using generative adversarial networks for adaptive radiotherapy
    Liugang Gao
    Kai Xie
    Xiaojin Wu
    Zhengda Lu
    Chunying Li
    Jiawei Sun
    Tao Lin
    Jianfeng Sui
    Xinye Ni
    Radiation Oncology, 16
  • [35] MAGAN: Mask Attention Generative Adversarial Network for Liver Tumor CT Image Synthesis
    Liu, Yang
    Meng, Lu
    Zhong, Jianping
    JOURNAL OF HEALTHCARE ENGINEERING, 2021, 2021
  • [36] Multi-Intensity Optimization-Based CT and Cone Beam CT Image Registration
    Xie, Lisiqi
    He, Kangjian
    Gong, Jian
    Xu, Dan
    ELECTRONICS, 2022, 11 (12)
  • [37] A feature invariant generative adversarial network for head and neck MRI/CT image synthesis
    Touati, Redha
    Le, William Trung
    Kadoury, Samuel
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (09):
  • [38] Hyperspectral Image Classification Based on Residual Generative Adversarial Network
    Chen Ming
    Xi Xiangyun
    Wang Yang
    LASER & OPTOELECTRONICS PROGRESS, 2022, 59 (22)
  • [39] Consolidated Image Quality QA for Diagnostic CT and Radiotherapy Cone Beam CT
    Doemer, A.
    Gingold, E.
    Misic, V.
    Podder, T.
    Yu, Y.
    Xiao, Y.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [40] Image quality assessment of synthetic CT from on-board cone-beam CT
    Guo, Alan
    Blais, Danis
    Carrier, Jean-Francois
    Bedwani, Stephane
    MEDICAL PHYSICS, 2021, 48 (08) : 4681 - 4682