Selective Stimulation of Latissimus Dorsi Muscle for Cardiac Assist

被引:0
|
作者
Dirk R. Thompson
John J. Michele
Erik A. Cheever
David T. George
机构
[1] Case Western Reserve University,Division of Cardiothoracic Surgery
[2] Philadelphia Heart Institute,undefined
[3] Swarthmore College,undefined
来源
关键词
Electromyogram; Thoracodorsal; Isometric; Cardiomyoplasty; Aortomyoplasty;
D O I
暂无
中图分类号
学科分类号
摘要
The contractile power of the latissimus dorsi muscle (LDM) is used in skeletal muscle cardiac assist (SMCA) to augment the blood pumping ability of a failing heart. The LDM has three anatomically distinct, independently innervate segments—the transverse, oblique, and lateral. There are potential advantages to selectively stimulating these LDM regions. We hypothesized that (1) the three nerve branches could be stimulated selectively to activate individual muscle regions with little or no functional overlap, (2) the three muscle regions would generate similar force, and (3) nerves stimulated in combinations would generate forces corresponding to the sum of forces generated by the individual regions. In acute studies of canine LDM (n=5), regional electromyogram (EMG) and isometric force were recorded while branches of the thoracodorsal nerve were stimulated (via nerve-cuff electrodes) individually and in combinations. Analysis of regional EMG and force confirmed selective activation. Stimulation of lateral, oblique, and transverse branches of thoracodorsal nerve activated 53 ±5%, 20 ± 9%, and 36 ± 9% of the muscle, respectively; with corresponding developed forces of 48 ± 6%, 21 ± 8%, and 31 ± 8% of total muscle force (R=0.98, p < 0.05). Selective activation of LDM is possible with little or no functional overlap; however, the muscle regions were nonuniform. Selective stimulation may ultimately facilitate the use of performance enhancing stimulus protocols for SMCA. © 1999 Biomedical Engineering Society.
引用
收藏
页码:48 / 55
页数:7
相关论文
共 50 条
  • [21] INTRAMUSCULAR ANATOMY OF THE LATISSIMUS DORSI MUSCLE
    CASSEL, JM
    BRITISH JOURNAL OF PLASTIC SURGERY, 1989, 42 (05): : 607 - 609
  • [22] LATISSIMUS DORSI MUSCLE FREE FLAPS
    BAILEY, BN
    GODFREY, AM
    BRITISH JOURNAL OF PLASTIC SURGERY, 1982, 35 (01): : 47 - 52
  • [23] Effect of variable and constant-frequency train in latissimus dorsi muscle stimulation
    Kashem, MA
    Santamore, WP
    Chiang, BBY
    Slater, AD
    BASIC AND APPLIED MYOLOGY, 1999, 9 (03): : 113 - 116
  • [24] OPTIMAL ELECTRICAL-STIMULATION FOR LATISSIMUS-DORSI MUSCLE AFTER CARDIOMYOPLASTY
    PEKARSKY, VV
    AKHMEDOV, SD
    DUBROVSKY, IA
    BATURIN, AV
    KRIVOSCHEKOV, EV
    RIZHIKH, AN
    PEKARSKAYA, MV
    JOURNAL OF CARDIAC SURGERY, 1993, 8 (02) : 172 - 176
  • [25] A Biceps Muscle Latissimus dorsi in a Dog
    Gil, Julio
    Olivares, Ricardo
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2014, 32 (04): : 1464 - 1466
  • [26] The latissimus dorsi bladder myoplasty to assist detrusor function
    von Heyden, B
    Anthony, JP
    Brock, GB
    Kaula, N
    Tanagho, EA
    UROLOGICAL RESEARCH, 1998, 26 (03): : 215 - 221
  • [27] APPLICATION OF THE LATISSIMUS DORSI MUSCLE TO THE HEART
    CHRIST, JE
    SPIRA, M
    ANNALS OF PLASTIC SURGERY, 1982, 8 (02) : 118 - 121
  • [28] Effect of stimulation rate on the blood flow and bioenergetics of the conditioned latissimus dorsi muscle
    Gealow, KK
    Zhang, JY
    Solien, EE
    Bianco, RW
    Shumway, SJ
    CARDIAC BIOASSIST, 1997, 11 : 297 - 309
  • [29] Robotic Latissimus Dorsi Muscle Harvest
    Selber, Jesse Creed
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2011, 128 (02) : 88E - 90E
  • [30] Mechanical properties of rabbit latissimus dorsi muscle after stretch and/or electrical stimulation
    James, RS
    Cox, VM
    Young, IS
    Altringham, JD
    Goldspink, DF
    JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (02) : 398 - 406