Clinical Utility of Temporal Subtraction Images in Successive Whole-Body Bone Scans: Evaluation in a Prospective Clinical Study

被引:0
|
作者
Junji Shiraishi
Daniel Appelbaum
Yonglin Pu
Roger Engelmann
Qiang Li
Kunio Doi
机构
[1] Kumamoto University,Department of Medical Physics, Division of Advanced Biomedical Sciences, Faculty of Life Sciences
[2] The University of Chicago,Department of Radiology
[3] Duke University,Department of Radiology
[4] Gunma Prefectural College of Health Sciences,undefined
来源
关键词
Bone scintigram; whole-body scan; interval change; temporal subtraction image; prospective clinical study;
D O I
暂无
中图分类号
学科分类号
摘要
In order to aid radiologists’ routine work for interpreting bone scan images, we developed a computerized method for temporal subtraction (TS) images which can highlight interval changes between successive whole-body bone scans, and we performed a prospective clinical study for evaluating the clinical utility of the TS images. We developed a TS image server which includes an automated image-retrieval system, an automated image-conversion system, an automated TS image-producing system, a computer interface for displaying and evaluating TS images with five subjective scales, and an automated data-archiving system. In this study, the radiologist could revise his/her report after reviewing the TS images if the findings on the TS image were confirmed retrospectively on our clinical picture archiving and communication system. We had 256 consenting patients of whom 143 had two or more whole-body bone scans available for TS images. In total, we obtained TS images successfully in 292 (96.1%) pairs and failed to produce TS images in 12 pairs. Among the 292 TS studies used for diagnosis, TS images were considered as “extremely beneficial” or “somewhat beneficial” in 247 (84.6%) pairs, as “no utility” in 44 pairs, and as “somewhat detrimental” in only one pair. There was no TS image for any pairs that was considered “extremely detrimental.” In addition, the radiologists changed their initial reported impression in 18 pairs (6.2%). The benefit to the radiologist of using TS images in the routine interpretation of successive whole-body bone scans was significant, with negligible detrimental effects.
引用
收藏
页码:680 / 687
页数:7
相关论文
共 50 条
  • [41] Whole-Body Electrostatic Pain Treatment in Adults with Chronic Pain: A Prospective Multicentric Observational Clinical Trial
    Stephan Steinhauser
    Michael Thomas Ganter
    Vincent Stadelmann
    Christoph Karl Hofer
    Pain and Therapy, 2024, 13 : 69 - 85
  • [42] Whole-body magnetic resonance imaging vs. clinical evaluation of enthesitis in patients with spondyloarthritis
    Zi-Kang Guo
    Yi-Meng Zhang
    Chun-Yu Kong
    Yang Liu
    Xiao-Dong Ji
    Ying Zhan
    Wu-Fang Qi
    Xin-Wei Lei
    中华医学杂志英文版, 2021, 134 (21) : 2638 - 2640
  • [43] INITIAL CLINICAL-EVALUATION OF A WHOLE-BODY NUCLEAR MAGNETIC-RESONANCE (NMR) TOMOGRAPH
    YOUNG, IR
    BAILES, DR
    BURL, M
    COLLINS, AG
    SMITH, DT
    MCDONNELL, MJ
    ORR, JS
    BANKS, LM
    BYDDER, GM
    GREENSPAN, RH
    STEINER, RE
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (01) : 1 - 18
  • [44] Whole-body magnetic resonance imaging vs. clinical evaluation of enthesitis in patients with spondyloarthritis
    Guo, Zi-Kang
    Zhang, Yi-Meng
    Kong, Chun-Yu
    Liu, Yang
    Ji, Xiao-Dong
    Zhan, Ying
    Qi, Wu-Fang
    Lei, Xin-Wei
    CHINESE MEDICAL JOURNAL, 2021, 134 (21) : 2638 - 2640
  • [45] Whole-body FDG-PET in children with idiopathic juvenile arthritis: An evaluation study in relation to symptoms and clinical findings
    Kanezawa, Noriko
    Tateishi, Ukihide
    Shizukuishi, Kazuya
    Okabe, Tetsuya
    Minamimoto, Ryogo
    Lee, Jin
    Inoue, Tomio
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [46] Spatially-guided non-local mean filter for denoising of clinical whole-body PET images
    Arabi, Hossein
    Zaidi, Habib
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [47] Whole-body positron emission tomography in clinical oncology: comparison between attenuation-corrected and uncorrected images
    Bengel, FM
    Ziegler, SI
    Avril, N
    Weber, W
    Laubenbacher, C
    Schwaiger, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (09): : 1091 - 1098
  • [48] Whole-body positron emission tomography in clinical oncology: Comparison between attenuation-corrected and uncorrected images
    Frank M. Bengel
    Sibylle I. Ziegler
    Norbert Avril
    Wolfgang Weber
    Christian Laubenbacher
    Markus Schwaiger
    European Journal of Nuclear Medicine, 1997, 24 (9) : 1091 - 1098
  • [49] Evaluation of a new multipurpose whole-body CzT-based camera: comparison with a dual-head Anger camera and first clinical images
    Desmonts, Cedric
    Bouthiba, Mohammed Abdeldjalil
    Enilorac, Blandine
    Nganoa, Catherine
    Agostini, Denis
    Aide, Nicolas
    EJNMMI PHYSICS, 2020, 7 (01)
  • [50] Evaluation of a new multipurpose whole-body CzT-based camera: comparison with a dual-head Anger camera and first clinical images
    Cédric Desmonts
    Mohammed Abdeldjalil Bouthiba
    Blandine Enilorac
    Catherine Nganoa
    Denis Agostini
    Nicolas Aide
    EJNMMI Physics, 7