Modeling the influent and effluent parameters concentrations of the industrial wastewater treatment under zeolite filtration

被引:0
|
作者
Behrouz Abolpour
Sahar Sheibani
Amir Eskandari
机构
[1] Agricultural Research,Agricultural Engineering Research Department, Fars Agricultural and Natural Resources Research
[2] Education and Extension Organization (AREEO),Visiting Scientist of Northwest Institute of Eco
[3] CAS,Environment and Resources (NIEER)
[4] Zabol University,undefined
[5] Azad University,undefined
来源
Soft Computing | 2023年 / 27卷
关键词
Zeolite; Industrial wastewater; Fuzzy set theory; Chemical oxygen demand; Salinity;
D O I
暂无
中图分类号
学科分类号
摘要
The maximum pollution of wastewater discharged into a treatment plant located in the industrial town of Shiraz, Fars, Iran, has been used to define the optimum condition of zeolite filtration. This study aimed to focus on controlling water salinity used to water the green area that have measured the concentration fluctuations of the influent and effluent parameters, e.g., Chemical Oxygen Demand (COD), Electrical Conductivity (EC), Temperature, Total Suspended Solids (TSS), Total Dissolved Solids (TDS), and pH. In the first step, we tried to obtain a model using general regressions, e.g., the linear or nonlinear approaches. Here, it was assumed that the reason for failing these approaches on modeling was an unsteady operation of the zeolite behavior on wastewater purgation, which could be trained by a lag-time associated with time series analysis, e.g., ARIMA. The second step was to use the Fuzzy Inference System, FIS, for finding the relation between the COD concentration value of the effluent with the concentrations of TDS, TSS, and EC of influent. Finally, to achieve a model for simulating the removal of COD against other parameters, the Adaptive Neural Fuzzy Inference System (ANFIS) was used. The vague and intangible zeolite behavior led to form the fuzzy inference systems, and there thus resulted in good distribution between estimated and observed data. Because the regression coefficient on comparing the simulated distribution of COD concentration of daily effluent with the line of 1:1 was 0.764. The results revealed that two extreme points existed for the fluctuations of COD concentration effluent led to its lowest or highest levels due to the concentration fluctuations of Na and NH4 + , where its removal efficiency has maximum or minimum without the steady-state conditions. This study observed that the role of zeolite was the disruption of ion-exchange stability by constantly arousing their interaction and has the reason of failure iteration to improve the regression coefficient of linear and nonlinear functions via the curve fitting approach and clustering analysis with and without normalized data. The fuzzy set theory was very helpful in this condition, such showed the soluble solids concentration (e.g., 1877 mg/l) on the discharge wastewater in the industrial treatment plant has a threshold value whose an important role in the zeolite filtration effectiveness.
引用
收藏
页码:5855 / 5872
页数:17
相关论文
共 50 条
  • [31] A dynamic model for predicting effluent concentrations of organic priority pollutants from an industrial wastewater treatment plant
    OBrien, GJ
    Teather, EW
    [J]. WATER ENVIRONMENT RESEARCH, 1995, 67 (06) : 935 - 942
  • [32] Influent generator for probabilistic modeling of nutrient removal wastewater treatment plants
    Talebizadeh, Mansour
    Belia, Evangelia
    Vanrolleghem, Peter A.
    [J]. ENVIRONMENTAL MODELLING & SOFTWARE, 2016, 77 : 32 - 49
  • [33] Elemental distribution in influent, biosolids, and effluent of five wastewater treatment plants in Savannah, Georgia, USA
    Sajwan, Kenneth
    Ballou, Kristopher
    Newsome, Tabias
    Morris, Triandos
    Meadows, Keyuandrea
    Loganathan, Bommanna
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [34] Occurrence of Antibiotics in Influent and Effluent from 3 Major Wastewater-Treatment Plants in Finland
    Kortesmaki, Ewelina
    Ostman, Johnny R.
    Meierjohann, Axel
    Brozinski, Jenny-Maria
    Eklund, Patrik
    Kronberg, Leif
    [J]. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2020, 39 (09) : 1774 - 1789
  • [35] Study of an eco-efficient method for wastewater treatment and safe agricultural reuse: Effect of influent splitting rates on effluent quality parameters
    El Moussaoui, Tawfik
    Belloulid, Mohamed Oussama
    El Ass, Khalid
    Mandi, Laila
    Wahbi, Said
    Masi, Salvatore
    Ouazzani, Naaila
    [J]. IRRIGATION AND DRAINAGE, 2024, 73 (01) : 304 - 321
  • [36] ADVANCED MEMBRANE FILTRATION FOR INDUSTRIAL WASTEWATER TREATMENT.
    Fournier, Christopher
    Rickenbach, Bradley
    [J]. Journal of the New England Water Pollution Control Association, 1986, 20 (02): : 147 - 154
  • [37] Deciphering basic and key traits of antibiotic resistome in influent and effluent of hospital wastewater treatment systems
    Zhu, Lin
    Yuan, Ling
    Shuai, Xin-Yi
    Lin, Ze-Jun
    Sun, Yu-Jie
    Zhou, Zhen-Chao
    Meng, Ling-Xuan
    Ju, Feng
    Chen, Hong
    [J]. WATER RESEARCH, 2023, 231
  • [38] Free synthetic and natural estrogen hormones in influent and effluent of three municipal wastewater treatment plants
    Chimchirian, Robert F.
    Suri, Rominder P. S.
    Fu, Hongxiang
    [J]. WATER ENVIRONMENT RESEARCH, 2007, 79 (09) : 969 - 974
  • [39] Molecular detection and genotyping of human noroviruses in influent and effluent water at a wastewater treatment plant in Japan
    Kitajima, M.
    Haramoto, E.
    Phanuwan, C.
    Katayama, H.
    Furumai, H.
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2012, 112 (03) : 605 - 613
  • [40] Advanced treatment of industrial wastewater by membrane filtration and ozonization
    Ferella, Francesco
    De Michelis, Ida
    Zerbini, Claudia
    Veglio, Francesco
    [J]. DESALINATION, 2013, 313 : 1 - 11