Evaluation of natural and tracer fluorescent emission methods for droplet size measurements in a diesel spray

被引:0
|
作者
J. V. Pastor
R. Payri
J. M. Salavert
J. Manin
机构
[1] Universidad Politécnica de Valencia,CMT
[2] Sandia National Laboratories, Motores Térmicos
关键词
Diesel spray; Sauter mean diameter (SMD); Laser-induced fluorescence (LIF); Rhodamine B; Fluorescence quantum yield;
D O I
暂无
中图分类号
学科分类号
摘要
Spray sizing that records fluorescent emission and scattered light has been widely applied to spray diagnostics over the last two decades. Different experimental strategies have been developed, but comparing the different solutions offered has remained of interest to experimentalists. In this work, a comparison of two fluorescence strategies for measuring droplet size in the liquid phase of a last-generation DI diesel spray is conducted. The natural fluorescent emission of a commercial diesel fuel and the fluorescence emitted by a tracer (Rhodamine B) are compared using theoretical and experimental approaches. The LIF/Mie ratio commonly called Planar Droplet Sizing (PDS) technique is applied in two different ways to elucidate the possible advantages of using a fluorescent dopant. The sprays were injected under non-evaporative conditions into a constant pressure vessel that simulates densities present at the moment of injection in currently used passenger car diesel engines. Characterization of the signal properties was performed by measuring the absorption coefficient, fluorescence emission spectrum, quantum yield and lifetime of both configurations. The scattered light and fluorescence intensities were calculated to verify the dependencies of the droplet surface and volume. When applying the two techniques to quantify droplet size in dense diesel sprays, the results show that signal weakness and lack of control over the properties of natural fluorescence produce distortion in the shape of the spray and cause measurements to be unreliable.
引用
收藏
页码:713 / 724
页数:11
相关论文
共 50 条
  • [21] A method of extending DPIV and its application in spray droplet size measurements
    Wang, XS
    Wu, XP
    Liao, GX
    CHINESE SCIENCE BULLETIN, 2002, 47 (12): : 1045 - 1049
  • [22] Droplet size and morphology characterization for dense sprays by image processing: application to the Diesel spray
    Blaisot, JB
    Yon, J
    EXPERIMENTS IN FLUIDS, 2005, 39 (06) : 977 - 994
  • [23] Droplet size and morphology characterization for dense sprays by image processing: application to the Diesel spray
    J. B. Blaisot
    J. Yon
    Experiments in Fluids, 2005, 39 : 977 - 994
  • [24] EFFECTS OF BACK PRESSURE AND AMBIENT DENSITY - DROPLET SIZE DISTRIBUTION IN DIESEL FUEL SPRAY
    TAKEUCHI, K
    SENDA, J
    YAMADA, K
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1984, 27 (232): : 2211 - 2218
  • [25] Development and droplet size characteristics of wall impinging diesel fuel spray at high injection pressure
    龚允怡
    李理光
    黄叶舟
    Progress in Natural Science, 1997, (05) : 97 - 105
  • [26] Numerical investigation of the effect of spray angle on emission characteristics of a diesel engine fueled with natural gas and diesel
    Balijepalli, Ramakrishna
    Kumar, Ankit
    Rajak, Upendra
    Elkotb, Mohamed Abdelghany
    Alwetaishi, Mamdooh
    Reddy, Siva Kumar Y.
    Dasore, Abhishek
    Verma, Tikendra Nath
    Saleel, C. Ahamed
    Afzal, Asif
    ENERGY REPORTS, 2021, 7 : 7273 - 7287
  • [27] DROPLET SIZE DISTRIBUTION IN DIESEL FUEL SPRAY (CONTINUED: EFFECTS OF BACK PRESSURE AND AMBIENT DENSITY).
    Takeuchi, Kiichiro
    Senda, Jiro
    Yamada, Koji
    1600, (27):
  • [28] Development and droplet size characteristics of wall impinging diesel fuel spray at high injection pressure
    Gong, YY
    Li, LG
    Huang, YZ
    PROGRESS IN NATURAL SCIENCE, 1997, 7 (05) : 607 - 615
  • [29] Measurements of a diesel spray with a normal size nozzle and a large-scale model
    Rantanen, P
    Valkonen, A
    Cronhjort, A
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1999, 20 (05) : 545 - 551
  • [30] Effect of liquid fuel droplet size on soot emission from turbulent spray flames
    Zahmatkesh, I.
    Moghiman, M.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY TRANSACTION B-ENGINEERING, 2006, 30 (B3): : 339 - 351