Removal of aspirin from aqueous solution using electroactive bacteria induced by alternating current

被引:0
|
作者
Zohreh Moghiseh
Abbas Rezaee
机构
[1] Tarbiat Modares University,Department of Environmental Health Engineering, Faculty of Medical Sciences
关键词
Emerging contaminant; Applied current; Biostimulation; Wastewater; Laccase; Dehydrogenase activity;
D O I
暂无
中图分类号
学科分类号
摘要
This study aims to improve bacterial laccase enzyme activity (LEA) and dehydrogenase activity (DHA) affecting acetylsalicylic acid (ASA) biodegradation using an alternating current (AC). A microbial consortium was inoculated in an electroactive bioreactor supplied with an AC by a function generator under operating conditions of amplitude (AMPL) = 2–10 peak-to-peak voltage (Vpp), optical fiber splice tray (OFST) = 0.1 V, and sine wave frequency = 10 Hz. The obtained results revealed that at an applied voltage of 8 Vpp and an OFST of 0.1 for 12 h, the maximum bacterial LEA and DHA were 30.6 U/mL and 75.5 micro grTF/cm2.gr biomass; respectively. Cell viability and permeability were equal to 95.7% and 0.3%; respectively, at the voltage of 8 Vpp. Moreover, liquid chromatography–mass spectrometry (LC-MS) and gas chromatography–mass spectrometry (GC-MS) analyses showed that by-products had lower intensity at 8 Vpp compared with that of 2 Vpp voltage. Finally, the results demonstrated an optimum applied voltage of the AC, which could stimulate and promote bacterial LEA and DHA. Therefore, an electroactive bioreactor supplied with an AC can be a novel system for stimulation of enzyme activities in the process of ASA biodegradation.
引用
收藏
页码:25327 / 25338
页数:11
相关论文
共 50 条
  • [31] Arsenate removal from aqueous solution using synthetic siderite
    Guo, Huaming
    Li, Yuan
    Zhao, Kai
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 176 (1-3) : 174 - 180
  • [32] Removal of Ce(IV) Ions from Aqueous Solutions Using Sawdust Coated by Electroactive Polymers
    Ansari, Reza
    Pornahad, Amin
    SEPARATION SCIENCE AND TECHNOLOGY, 2010, 45 (16) : 2376 - 2382
  • [33] Removal of Eosin Y, an Anionic Dye, from Aqueous Solutions Using Conducting Electroactive Polymers
    Ansari, Reza
    Mosayebzadeh, Zahra
    IRANIAN POLYMER JOURNAL, 2010, 19 (07) : 541 - 551
  • [34] Novel application of maghemite nanoparticles coated bacteria for the removal of cadmium from aqueous solution
    Devatha, C. P.
    Shivani, S.
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2020, 258
  • [35] A Comprehensive Review of the Current Progress of Chromium Removal Methods from Aqueous Solution
    Islam, Md. Monjurul
    Mohana, Anika Amir
    Rahman, Md. Aminur
    Rahman, Mahbubur
    Naidu, Ravi
    Rahman, Mohammad Mahmudur
    TOXICS, 2023, 11 (03)
  • [36] INTERFERENCE FROM INDUCED ALTERNATING CURRENT
    PAVER, EC
    MATERIALS PROTECTION, 1969, 8 (12): : 38 - &
  • [37] Metal removal from aqueous solution
    British Nuclear Fuels plc, Cambridge, United Kingdom
    Biotechnol Adv, 3-4 (798):
  • [38] Preparation, characterization and removal of hazardous reactive violet dye from aqueous solution using activated carbon and electroactive conducting polymer - a comparative study
    Supriya, S.
    Palanisamy, P. N.
    DESALINATION AND WATER TREATMENT, 2017, 78 : 281 - 291
  • [39] Removal of chromium from aqueous solution
    Lee, CK
    Low, KS
    Kek, KL
    BIORESOURCE TECHNOLOGY, 1995, 54 (02) : 183 - 189
  • [40] Removal of fluoride from aqueous solution using protonated chitosan beads
    Viswanathan, Natrayasamy
    Sundaram, C. Sairam
    Meenakshi, S.
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 161 (01) : 423 - 430