Failure analysis of a high-temperature thermocouple

被引:6
|
作者
Gates K. [1 ]
Benhaddad S. [2 ]
机构
[1] Thermex Metal Treating, Edmonton, Alta. T6P 1N8
[2] Versa Power Systems, Calgary, Alta. T2B 3R2
关键词
Catastrophic failure; Contamination; Failure analysis; High temperature; Materials selection; Metallurgical investigation; Nonferrous metals;
D O I
10.1361/154770205X55108
中图分类号
学科分类号
摘要
A solid oxide fuel cell unit operates at high temperatures of 700 to 800 °C. The operation of the unit is controlled by a set of instrumentation including sensors, thermocouples, and voltage leads. Two S-thermocouples were inserted in the after-burner where temperature is constantly at 1000 °C. During operation of one prototype unit and after 1000 h, the thermocouples started to give erratic readings and led to complete shutdown of the unit. Analysis of the thermocouples revealed a series of events may have occurred due to stress induced by the design, materials and operating conditions, contamination during manufacturing, or a reducing environment caused by sheathing. The specification from S-type to B-type may remove the risk of reoccurrence. A design change in platinum burner thermocouples to ensure an oxygen-rich environment for the platinum was also recommended. © ASM International.
引用
下载
收藏
页码:14 / 19
页数:5
相关论文
共 50 条
  • [1] High-temperature thermocouple calibrations
    Sawayda, David
    Test Engineering and Management, 1995, 57 (02): : 10 - 13
  • [2] HIGH-TEMPERATURE THERMOCOUPLE BASED ON GRAPHITE
    MALYSHEV, VN
    INDUSTRIAL LABORATORY, 1969, 35 (07): : 1064 - &
  • [3] HIGH-TEMPERATURE THERMAL ANALYSIS USING THE TUNGSTEN MOLYBDENUM THERMOCOUPLE
    GREENAWAY, HT
    JOHNSTONE, STM
    MCQUILLAN, MK
    JOURNAL OF THE INSTITUTE OF METALS, 1951, 80 (03): : 109 - 114
  • [4] HEAT INSULATION FOR A HIGH-TEMPERATURE THERMOCOUPLE BLOCK
    ERMAKOV, ON
    EMELYANOV, VA
    FARAFONOV, VF
    RYABOV, VV
    REFRACTORIES, 1982, 23 (9-10): : 555 - 556
  • [5] A NOZZLE THERMOCOUPLE FOR MEASUREMENTS IN HIGH-TEMPERATURE GASES
    DONNE, MD
    BOWDITCH, FH
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1967, 10 (04) : 477 - &
  • [6] Heat transfer error analysis of high-temperature wall temperature measurement using thermocouple
    Kou, Zhihai
    Wu, Rongxiang
    Wang, Qingyin
    Li, Binbin
    Li, Congzheng
    Yin, Xunyan
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 59
  • [7] Melting Temperature of High-Temperature Fixed Points for Thermocouple Calibrations
    J. V. Pearce
    V. Montag
    D. Lowe
    W. Dong
    International Journal of Thermophysics, 2011, 32 : 463 - 470
  • [8] Melting Temperature of High-Temperature Fixed Points for Thermocouple Calibrations
    Pearce, J. V.
    Montag, V.
    Lowe, D.
    Dong, W.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (1-2) : 463 - 470
  • [9] A Novel Ceramic Thermocouple Used in High-temperature Measurement
    Feng, Lichao
    Xie, Ning
    Shao, Wenzhu
    Cui, Yusheng
    Zhen, Liang
    NEW AND ADVANCED MATERIALS, PTS 1 AND 2, 2011, 197-198 : 328 - +
  • [10] NEW HIGH-TEMPERATURE NOBLE-METAL THERMOCOUPLE PAIRING
    GLAWE, GE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (08): : 1107 - 1108