Acoustic thermometric reconstruction of a time-varying temperature profile

被引:0
|
作者
A. A. Anosov
A. S. Kazanskii
A. D. Mansfel’d
A. S. Sharakshane
机构
[1] Russian Academy of Sciences,Kotel’nikov Institute of Radio Engineering and Electronics
[2] Sechenov First Moscow State Medical University,Applied Physics Institute
[3] Russian Academy of Sciences,undefined
来源
Acoustical Physics | 2016年 / 62卷
关键词
thermal acoustic radiation; thermal profile reconstruction;
D O I
暂无
中图分类号
学科分类号
摘要
The time-varying temperature profiles were reconstructed in an experiment using a thermal acoustic radiation receiving array containing 14 sensors. The temperature was recovered by performing similar experiments using plasticine, as well as in vivo with a human hand. Plasticine preliminarily heated up to 36.5°C and a human hand were placed into water for 50 s at a temperature of 20°C. The core temperature of the plasticine was independently measured using thermocouples. The spatial resolution of the reconstruction in the lateral direction was determined by the distance between neighboring sensors and was equal to10 mm; the averaging time was 10 s. The error in reconstructing the core temperature determined in the experiment with plasticine was 0.5 K. The core temperature of the hand changed with time (in 50 s it decreased from 35 to 34°C) and space (the mean square deviation was 1.5 K). The experiment with the hand revealed that multichannel detection of thermal acoustic radiation using a compact 45 × 36 mm array to reconstruct the temperature profile could be performed during medical procedures.
引用
收藏
页码:255 / 261