The measurement of blood flow parameters with deuterium stable isotope MR imaging

被引:0
|
作者
Furuya Y. [1 ]
Ikehira H. [1 ,2 ]
Obata T. [1 ]
Koga M. [1 ]
Yoshida K. [1 ]
机构
[1] Div. Adv. Technol. for Med. Imaging, Res. Ctr. of Charged Particle Tech.
[2] Div. Adv. Technol. for Med. Imaging, Res. Ctr. of Charged Particle Tech., Natl. Inst. of Radiological Sciences, Inage-ku, Chiba 263, 4-9-1, Anagawa
关键词
!sup]2[!/sup]D-MRI; Blood flow; Brain; Heart; Skeletal muscle;
D O I
10.1007/BF03165294
中图分类号
学科分类号
摘要
Methods: Because there are no radioactive hydrogen isotopes which can be used for clinical examinations, deuterium as a non-radioactive, freely diffusible tracer has some advantages compared with the radioactive tracers in the measurement of blood flow parameters. A non-invasive technique to estimate the mean tissue blood flow parameter in vivo was developed by using deuterium nuclear magnetic resonance (NMR) imaging in rat. We obtained the NMR signal changes from deuterium NMR images in nine male Wistar rats after intravenous injection of D2O and applied exponential curve fitting analyses to calculate blood flow parameters of the brain, heart and skeletal muscle. Results: While fitting the reducing of the monoexponential function yielded a blood flow parameter of 27.9 ± 1.6 ml/min/100 g tissue weight for the brain and 46.7 ± 3.7 ml/min/100 g tissue weight for the heart, fitting the early reducing of the signal intensity of the biexponential function yielded a blood flow parameter of 95.6 ± 10.9 ml/min/100 g tissue weight for the brain and 108.0 ± 13.1 ml/min/100 g tissue weight for the heart. The mean muscle blood flow parameter determined by the monoexponential uptake function was 43.8 ± 7.3 ml/min/100 g tissue weight. Conclusions: The blood flow parameter measurement by means of an imaging coil for deuterium is less invasive and reflects the mean tissue blood flow parameter for the entire tissue sample more homogeneously than spectroscopic monitoring.
引用
收藏
页码:281 / 284
页数:3
相关论文
共 50 条
  • [21] MEASUREMENT OF REGIONAL CEREBRAL BLOOD FLOW BY INTRAVENOUS ISOTOPE INJECTION
    AUSTIN, G
    HORN, N
    ROUHE, S
    HAYWARD, W
    CIRCULATION, 1971, 44 (04) : 110 - &
  • [22] MR MEASUREMENT OF BLOOD-FLOW IN THE CARDIOVASCULAR-SYSTEM
    MOSTBECK, GH
    CAPUTO, GR
    HIGGINS, CB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (03) : 453 - 461
  • [23] Optimizing dynamic T2*MR imaging for measurement of cerebral blood flow using infusions for cerebral blood volume
    Newman, G. C.
    Hospod, F. E.
    Fain, S. B.
    Cook, T. D.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (06) : 1239 - 1240
  • [24] Transit time ultrasound perivascular flow probe technology is superior to MR imaging on hepatic blood flow measurement in a porcine model
    Mohamed Bekheit
    Chloe Audebert
    Petru Bucur
    Hans Adriaensen
    Emilie Bled
    Mylène Wartenberg
    Irene Vignon-Clementel
    Eric Vibert
    Hepatobiliary & Pancreatic Diseases International, 2018, 17 (06) : 538 - 545
  • [25] Transit time ultrasound perivascular flow probe technology is superior to MR imaging on hepatic blood flow measurement in a porcine model
    Bekheit, Mohamed
    Audebert, Chloe
    Bucur, Petru
    Adriaensen, Hans
    Bled, Emilie
    Wartenberg, Mylene
    Vignon-Clementel, Irene
    Vibert, Eric
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2018, 17 (06) : 538 - 545
  • [26] CUTANEOUS BLOOD-FLOW CHANGES DURING MR IMAGING
    SHELLOCK, FG
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) : 1059 - 1059
  • [27] MR IMAGING OF CHOROIDAL BLOOD-FLOW IN GLAUCOMATOUS EYES
    SINGH, OS
    KWONG, K
    LASHKARI, K
    LEE, KY
    CHENG, HM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1077 - 1077
  • [28] Stable isotope deuterium as a natural tracer of mixing processes in rivers
    Palige, Jacek
    Ptaszek, Sywia
    Zimnicki, Robert
    Chmielewski, Andrzej G.
    Wierzchnicki, Ryszard
    NUKLEONIKA, 2008, 53 (02) : 63 - 67
  • [29] THE ROLE OF ISOTOPE LIMB BLOOD-FLOW MEASUREMENT IN THE MANAGEMENT OF AN ARTERIOPATH
    PARKIN, A
    ROBINSON, PJ
    VOWDEN, P
    WILKINSON, D
    SALTER, MCP
    KESTER, RC
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1987, 8 (01): : 80 - 80