The measurement of blood flow parameters with deuterium stable isotope MR imaging

被引:0
|
作者
Furuya Y. [1 ]
Ikehira H. [1 ,2 ]
Obata T. [1 ]
Koga M. [1 ]
Yoshida K. [1 ]
机构
[1] Div. Adv. Technol. for Med. Imaging, Res. Ctr. of Charged Particle Tech.
[2] Div. Adv. Technol. for Med. Imaging, Res. Ctr. of Charged Particle Tech., Natl. Inst. of Radiological Sciences, Inage-ku, Chiba 263, 4-9-1, Anagawa
关键词
!sup]2[!/sup]D-MRI; Blood flow; Brain; Heart; Skeletal muscle;
D O I
10.1007/BF03165294
中图分类号
学科分类号
摘要
Methods: Because there are no radioactive hydrogen isotopes which can be used for clinical examinations, deuterium as a non-radioactive, freely diffusible tracer has some advantages compared with the radioactive tracers in the measurement of blood flow parameters. A non-invasive technique to estimate the mean tissue blood flow parameter in vivo was developed by using deuterium nuclear magnetic resonance (NMR) imaging in rat. We obtained the NMR signal changes from deuterium NMR images in nine male Wistar rats after intravenous injection of D2O and applied exponential curve fitting analyses to calculate blood flow parameters of the brain, heart and skeletal muscle. Results: While fitting the reducing of the monoexponential function yielded a blood flow parameter of 27.9 ± 1.6 ml/min/100 g tissue weight for the brain and 46.7 ± 3.7 ml/min/100 g tissue weight for the heart, fitting the early reducing of the signal intensity of the biexponential function yielded a blood flow parameter of 95.6 ± 10.9 ml/min/100 g tissue weight for the brain and 108.0 ± 13.1 ml/min/100 g tissue weight for the heart. The mean muscle blood flow parameter determined by the monoexponential uptake function was 43.8 ± 7.3 ml/min/100 g tissue weight. Conclusions: The blood flow parameter measurement by means of an imaging coil for deuterium is less invasive and reflects the mean tissue blood flow parameter for the entire tissue sample more homogeneously than spectroscopic monitoring.
引用
收藏
页码:281 / 284
页数:3
相关论文
共 50 条
  • [1] PORTAL BLOOD-FLOW - MEASUREMENT WITH MR IMAGING
    TAMADA, T
    MORIYASU, F
    ONO, S
    SHIMIZU, K
    KAJIMURA, K
    SOH, Y
    KAWASAKI, T
    KIMURA, T
    YAMASHITA, Y
    SOMEDA, H
    HAMATO, N
    UCHINO, H
    RADIOLOGY, 1989, 173 (03) : 639 - 644
  • [2] Renal blood flow: Measurement in vivo with rapid spiral MR imaging
    Sommer, G
    Corrigan, G
    Fredrickson, J
    Sawyer-Glover, A
    Liao, JR
    Myers, B
    Pelc, N
    RADIOLOGY, 1998, 208 (03) : 729 - 734
  • [3] MEASUREMENT OF RELATIVE REGIONAL TUMOR BLOOD-FLOW IN MICE BY DEUTERIUM NMR IMAGING
    EVELHOCH, JL
    MCDOUALL, JBL
    MATTIELLO, J
    SIMPSON, NE
    MAGNETIC RESONANCE IN MEDICINE, 1992, 24 (01) : 42 - 52
  • [4] MR measurement of coronary blood flow
    Sakuma, H
    Kawada, N
    Takeda, K
    Higgins, CB
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (05) : 728 - 733
  • [5] Azygos blood flow in cirrhosis: Measurement with MR imaging and correlation with variceal hemorrhage
    Wu, MT
    Pan, HB
    Chen, C
    Chang, JM
    Lo, GH
    Wu, SS
    Yeung, HN
    Yang, CF
    RADIOLOGY, 1996, 198 (02) : 457 - 462
  • [6] MR FLOW MEASUREMENT WITH 2D PHASE-CONTRAST IMAGING - ASSESSMENT OF IMAGING PARAMETERS
    DARKAZANLI, A
    AKATA, S
    GMITRO, AF
    UNGER, EC
    YOSHINO, MT
    RADIOLOGY, 1992, 185 : 272 - 273
  • [7] Prostate MR Imaging: Tissue Characterization with Pharmacokinetic Volume and Blood Flow Parameters and Correlation with Histologic Parameters
    Franiel, Tobias
    Luedemann, Lutz
    Rudolph, Birgit
    Rehbein, Hagen
    Stephan, Carsten
    Taupitz, Matthias
    Beyersdorff, Dirk
    RADIOLOGY, 2009, 252 (01) : 101 - 108
  • [8] Memory effect in deuterium analysis by continuous flow isotope ratio measurement
    Olsen, Jesper
    Seierstad, Inger
    Vinther, Bo
    Johnsen, Sigfus
    Heinemeier, Jan
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 254 (1-2) : 44 - 52
  • [9] MR imaging of renal allografts with cine-phase contrast blood flow measurement
    Smith, JK
    Kenney, PJ
    Queen, EP
    RADIOLOGY, 1996, 201 : 1595 - 1595
  • [10] MR IMAGING OF INPLANE BLOOD-FLOW
    PRICE, RR
    PICKENS, DR
    SMITH, G
    PATTON, JA
    PARTAIN, CL
    JAMES, AE
    MEDICAL PHYSICS, 1986, 13 (04) : 584 - 584