Construction and performance test of prototype parallel plate avalanche counters at RAON

被引:0
|
作者
Charles Akers
Kwang Bok Lee
Young Jin Kim
Eun Hee Kim
Young Kwan Kwon
Hyo Sang Lee
Jun Young Moon
Jin Hyung Park
Min Sang Ryu
Taeksu Shin
Satou Yoshiteru
机构
[1] Institute for Basic Science,Rare Isotope Science Project
来源
Journal of the Korean Physical Society | 2017年 / 70卷
关键词
PPAC; RISP; RAON; Position sensitive; delay-line readout;
D O I
暂无
中图分类号
学科分类号
摘要
Two prototype position sensitive parallel plate avalanche counters (PPACs) have been fabricated at the Rare Isotope Science Project (RISP). Both detectors have active areas of 10 × 10 cm2 and utilize a stripped electrode structure, together with a delay line readout, to extract position information. Testing was conducted with an 241Am α source, and 2-dimensional position information was obtained. A position resolution of 0.55 mm full width at half maximum (FWHM), together with a position linearity of ±55 μm over a 67-mm detection range, were measured. A time resolution of 450 ps (FWHM) was also measured.
引用
收藏
页码:682 / 686
页数:4
相关论文
共 50 条
  • [21] PARALLEL PLATE SPARK COUNTERS IN MAGNETIC FIELDS
    HEREFORD, FL
    PHYSICAL REVIEW, 1951, 82 (02): : 318 - 318
  • [22] TEST AND PERFORMANCE OF POSITION-SENSITIVE PARALLEL PLATE AVALANCHE DETECTORS IN HEAVY-ION KINEMATIC COINCIDENCE MEASUREMENTS
    SCHANDERA, C
    LAUTERBACH, C
    DEBOER, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 217 (1-2): : 128 - 130
  • [23] PERFORMANCE OF A POSITION-SENSITIVE MULTISTEP PARALLEL-PLATE AVALANCHE CHAMBER
    BHATTACHARYA, P
    BASU, P
    CHATTERJEE, ML
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 276 (03): : 585 - 587
  • [24] Performance of a real-size prototype neutron detector for the LAMPS at RAON
    Kisoo Lee
    Kyong Sei Lee
    Byungsik Hong
    Bumgon Kim
    Shin Hyung Kim
    Jae Beom Park
    Jae Hee Yoo
    Young Jin Kim
    Taeksu Shin
    Journal of the Korean Physical Society, 2014, 65 : 610 - 615
  • [25] Performance of a real-size prototype neutron detector for the LAMPS at RAON
    Lee, Kisoo
    Lee, Kyong Sei
    Hong, Byungsik
    Kim, Bumgon
    Kim, Shin Hyung
    Park, Jae Beom
    Yoo, Jae Hee
    Kim, Young Jin
    Shin, Taeksu
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (05) : 610 - 615
  • [26] LARGE AREA PARALLEL PLATE AVALANCHE COUNTER
    STELZER, H
    NUCLEAR INSTRUMENTS & METHODS, 1976, 133 (03): : 409 - 413
  • [27] AN IMPROVED QUENCH CIRCUIT FOR PARALLEL-PLATE COUNTERS
    HUDSON, DE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1951, 22 (11): : 850 - 850
  • [28] Pulse-Shape Discrimination of Alpha Particles of Different Specific Energy-Loss With Parallel-Plate Avalanche Counters
    Nakhostin, M.
    Baba, M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (03) : 1326 - 1332
  • [29] Performance of a parallel plate volume cell prototype for a fast iron/gas calorimeter
    Bizzeti, A.
    Civinini, C.
    D'Alessandro, R.
    Ferrando, A.
    Malinin, A.
    Martinez-Laso, L.
    Pojidaev, V.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A335 (1-2) : 102 - 105
  • [30] Source test of the prototype neutron detector for the large-acceptance multipurpose spectrometer at RAON
    Kisoo Lee
    Kyong Sei Lee
    Benard Mulilo
    Byungsik Hong
    Journal of the Korean Physical Society, 2013, 62 : 1227 - 1232