Direct Shear Behavior of a Mixture of Sand and Tire Chips Using X-ray Computed Tomography and Discrete Element Method

被引:0
|
作者
Bastien Chevalier
Yohei Tsutsumi
Jun Otani
机构
[1] Université Clermont Auvergne,X
[2] CNRS,earth Center
[3] SIGMA Clermont,undefined
[4] Institut Pascal,undefined
[5] Tokyo Metropolitan Government,undefined
[6] Kumamoto University,undefined
关键词
Discrete element method; Direct shear test; Displacement; Failure; Granular materials; X-ray CT;
D O I
暂无
中图分类号
学科分类号
摘要
Granular materials such as soils, powders, and other particulate materials have been widely used in geotechnical engineering. In particular, sandy soils are one of the representative ones. Recently, there has been attention on environment-friendly materials such as tire chips or other waste materials. Besides, one of the key behaviors for these materials is shear behavior, including the effect of dilatancy. In this paper, direct shear behavior of sands as rigid particles and tire chips as elastic particles is discussed. Here, micro-focus-type X-ray-computed tomography (CT) scanner is used with direct shear tests to investigate the close behavior in granular materials. To discuss the results of CT scanning quantitatively, a digital image correlation method is used and then, the distribution of the displacements in the shear box, shear strain, and volumetric strain are measured using CT data. In addition, a series of numerical analysis using discrete element method (DEM), which is often used for granular materials, is carried out for the same cases as direct shear test to validate the CT results. Finally, based on the comparative discussion between test results with CT scanning and DEM results, the direct shear behavior of different granular materials is precisely investigated for the first time using X-ray CT. The use of tire chips mixed with sand decreases the dilatant behavior under shear stress, and the peaks in shear stress are no longer observed. In addition, tire chips seem to prevent shear bands to propagate in the material.
引用
下载
收藏
相关论文
共 50 条
  • [41] Direct Observation of Faulting by Means of Rotary Shear Tests Under X-Ray Micro-Computed Tomography
    Zhao, Qi
    Tisato, Nicola
    Kovaleva, Olga
    Grasselli, Giovanni
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2018, 123 (09) : 7389 - 7403
  • [42] Isotropic compression behavior of granular assembly with non-spherical particles by X-ray micro-computed tomography and discrete element modeling
    Zhang, Nan
    Hedayat, Ahmadreza
    Han, Shaoyang
    Yang, Runlin
    Bolatios Sosa, Hector Gelber
    Gonzalez Cardenas, Juan Jose
    Salas Alvarez, Guido Edgard
    JOURNAL OF ROCK MECHANICS AND GEOTECHNICAL ENGINEERING, 2021, 13 (05) : 972 - 984
  • [43] Isotropic compression behavior of granular assembly with non-spherical particles by X-ray micro-computed tomography and discrete element modeling
    Nan Zhang
    Ahmadreza Hedayat
    Shaoyang Han
    Runlin Yang
    Héctor Gelber Bola?os Sosa
    Juan José González Cárdenas
    Guido Edgard Salas álvarez
    Journal of Rock Mechanics and Geotechnical Engineering, 2021, (05) : 972 - 984
  • [44] Evaluation of effect of tire chips in the cement stabilized soil using X-ray CT
    Mitarai, Y.
    Nakamura, Y.
    Otani, J.
    SCRAP TIRE DERIVED GEOMATERIALS: OPPORTUNITIES AND CHALLENGES, 2008, : 223 - 228
  • [45] Estimation of measurement uncertainties in X-ray computed tomography metrology using the substitution method
    Muller, P.
    Hiller, J.
    Dai, Y.
    Andreasen, J. L.
    Hansen, H. N.
    De Chiffre, L.
    CIRP JOURNAL OF MANUFACTURING SCIENCE AND TECHNOLOGY, 2014, 7 (03) : 222 - 232
  • [46] Measurement uncertainty evaluation in dimensional X-ray computed tomography using the bootstrap method
    Jochen Hiller
    Gianfranco Genta
    Giulio Barbato
    Leonardo De Chiffre
    Raffaello Levi
    International Journal of Precision Engineering and Manufacturing, 2014, 15 : 617 - 622
  • [47] Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method
    Dilmanian, FA
    Zhong, Z
    Ren, B
    Wu, XY
    Chapman, LD
    Orion, I
    Thomlinson, WC
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04): : 933 - 946
  • [48] Analysis of tangential contact damping mechanism by direct observation using X-ray computed tomography
    Kono, Daisuke
    Yamazaki, Taisuke
    Ishii, Tomohiro
    Kimura, Masao
    CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2022, 71 (01) : 485 - 488
  • [49] Measurement Uncertainty Evaluation in Dimensional X-ray Computed Tomography Using the Bootstrap Method
    Hiller, Jochen
    Genta, Gianfranco
    Barbato, Giulio
    De Chiffre, Leonardo
    Levi, Raffaello
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2014, 15 (04) : 617 - 622
  • [50] X-ray computed tomography technique to observe shear banding in dense sands
    Tani, K
    DEFORMATION AND PROGRESSIVE FAILURE IN GEOMECHANICS - IS-NAGOYA'97, 1997, : 315 - 320