Electrochemical analysis of methyl orange and simultaneous analysis with tartrazine using the poly(riboflavin)-modified carbon paste electrode

被引:0
|
作者
M. Asha
J. G. Manjunatha
K. P. Moulya
Samar A. Aldossari
Mohammed S. Mushab
S. Nagashree
机构
[1] Constituent College of Mangalore University,Department of Chemistry, FMKMC College
[2] King Saud University,Department of Chemistry, College of Science
[3] JSS Science and Technological University Mysuru,Department of Chemistry
关键词
Methyl orange; Riboflavin; Tartrazine; Impedance study; Carbon paste electrode; Sensors; Voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
引用
下载
收藏
页码:37 / 45
页数:8
相关论文
共 50 条
  • [21] Simultaneous Electrochemical Analysis of Ibuprofen and Paracetamol by Clay Modified Carbon Paste Electrode: Analytical Application in Human Blood
    El Ouafy, Hayat
    Aamor, Mouna
    Oubenali, Mustapha
    Mbarki, Mohamed
    El Haimouti, Aziz
    El Ouafy, Tarik
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (01): : 18 - 31
  • [22] Electrochemical analysis of catecholamines at a carbon paste electrode modified with copper(II) phthalocyanine
    Laber, Charles H.
    Garrison, Kenneth E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [23] Simultaneous Electrochemical Determination of Hydroquinone and Bisphenol A using a Carbon Paste Electrode Modified with Silver Nanoparticles
    Ianesko, Felipe
    de Lima, Camila Alves
    Antoniazzi, Cristiane
    Santana, Edson Roberto
    Piovesan, Jamille Valeria
    Spinelli, Almir
    Galli, Andressa
    de Castro, Eryza Guimaraes
    ELECTROANALYSIS, 2018, 30 (09) : 1946 - 1955
  • [24] The Electrochemical Resolution of Ciprofloxacin, Riboflavin and Estriol Using Anionic Surfactant and Polymer-Modified Carbon Paste Electrode
    Pushpanjali, Pemmatte A.
    Manjunatha, Jamballi G.
    Shreenivas, Mellekatte T.
    CHEMISTRYSELECT, 2019, 4 (46): : 13427 - 13433
  • [25] Electrochemical analysis of mercury using a Kryptofix carbon-paste electrode
    Zejli, H.
    de Cisneros, J. L. Hidalgo-Hidalgo
    Naranjo-Rodriguez, I.
    Elbouhouti, H.
    Choukairi, M.
    Bouchta, D.
    Temsamani, K. R.
    ANALYTICAL LETTERS, 2007, 40 (14) : 2788 - 2798
  • [26] Application of poly(acridine orange) and graphene modified carbon/ionic liquid paste electrode for the sensitive electrochemical detection of rutin
    Sun, Wei
    Wang, Yuhua
    Gong, Shixing
    Cheng, Yong
    Shi, Fan
    Sun, Zhenfan
    ELECTROCHIMICA ACTA, 2013, 109 : 298 - 304
  • [27] Electrochemical analysis of D-penicillamine using a carbon paste electrode modified with ferrocene carboxylic acid
    Raoof, Jahan-Bakhsh
    Ojani, Reza
    Chekin, Freshteh
    ELECTROANALYSIS, 2007, 19 (18) : 1883 - 1889
  • [28] Sensitive Electrochemical Analysis of Resorcinol using Polymer Modified Carbon Paste Electrode: A Cyclic Voltammetric Study
    Raril, Chenthattil
    Manjunatha, Jamballi G.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (04): : 488 - 498
  • [29] Evaluating the Electrochemical Detection of Methyldopa in the Presence of Hydrochlorothiazide Using a Modified Carbon Paste Electrode and Voltammetric Analysis
    Saman Borji
    Hadi Beitollahi
    Fariba Garkani Nejad
    Topics in Catalysis, 2024, 67 : 773 - 784
  • [30] Evaluating the Electrochemical Detection of Methyldopa in the Presence of Hydrochlorothiazide Using a Modified Carbon Paste Electrode and Voltammetric Analysis
    Borji, Saman
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    TOPICS IN CATALYSIS, 2024, 67 (9-12) : 773 - 784