The accuracy and trending ability of cardiac index measured by the fourth-generation FloTrac/Vigileo system™ and the Fick method in cardiac surgery patients

被引:0
|
作者
Takuma Maeda
Eisuke Hamaguchi
Naoko Kubo
Akira Shimokawa
Hiroko Kanazawa
Yoshihiko Ohnishi
机构
[1] National Cerebral and Cardiovascular Center,Department of Anesthesiology
[2] National Cerebral and Cardiovascular Center,Division of Transfusion Medicine
来源
Journal of Clinical Monitoring and Computing | 2019年 / 33卷
关键词
Blood pressure monitor; Cardiac output; Fick principle; Thermodilution;
D O I
暂无
中图分类号
学科分类号
摘要
To compare the accuracy and trending ability of the cardiac index (CI) measured by FloTrac/Vigileo™ (CIFT) or derived by the Fick equation (CIFick) using E-CAiOVX (enables continuous monitoring of oxygen consumption) with that measured by thermodilution (CITD) in patients with off-pump coronary artery bypass surgery. Twenty-two patients undergoing elective off-pump coronary artery bypass surgery were included. CIFT and CIFick were determined simultaneously at six time-points during off-pump coronary artery bypass surgery. At each time-point, phenylephrine (50 µg) was administered to increase systematic vascular resistance, with CI measured before and after administration (CITD used as reference method). Agreement of each method was evaluated by Bland–Altman analysis, while trending ability was evaluated by four-quadrant plot analysis and polar plot analysis. By Bland–Altman analysis, CIFT and CIFick showed percentage errors of 49.5% and 78.6%, respectively, compared with CITD. Subgroup analysis showed a percentage error between COFT and COTD of 28.9% in patients with a CI ≥ 2.4 L/min/m2, and 78.1% in patients with a CI ≥ 2.4 L/min/m2. The concordance rate of four-quadrant plot analysis was 93.3% for CIFT and 66.7% for CIFick in datasets where CITD ≥ 2.4 L/min/m2 before and after phenylephrine administration were included. CIFT and CIFick had wide limits of agreement with CITD, and were below acceptable limits for tracking phenylephrine-induced CI changes. However, subgroup analysis showed improved accuracy and trending ability of CIFT when only points where CITD ≥ 2.4 L/min/m2 were included, while there was no improvement in CIFick accuracy or trending ability.
引用
收藏
页码:767 / 776
页数:9
相关论文
共 50 条
  • [21] FloTrac/Vigileo™ (Third Generation) and MostCare®/PRAM Versus Echocardiography for Cardiac Output Estimation in Vascular Surgery
    Romagnoli, Stefano
    Ricci, Zaccaria
    Romano, Salvatore M.
    Dimizio, Fabio
    Bonicolini, Eleonora
    Quattrone, Diego
    De Gaudio, Raffaele
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (06) : 1114 - 1121
  • [22] The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study
    Yohei Sotomi
    Katsuomi Iwakura
    Yoshiharu Higuchi
    Kazuo Abe
    Junko Yoshida
    Takafumi Masai
    Kenshi Fujii
    Journal of Clinical Monitoring and Computing, 2013, 27 : 639 - 646
  • [23] Effect of different doses of remifentanil on cardiac output with FloTrac/Vigileo system during spine surgery
    Asouhidou, I.
    Ioannou, P.
    Kemanetzi, I.
    Vaidis, G.
    Vitoula, C.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 43 - 43
  • [24] LINEAR CORRELATION BETWEEN THE ACCURACY OF CARDIAC OUTPUT MEASUREMENT WITH FLOTRAC/VIGILEO SYSTEM AND SYSTEMIC VASCULAR RESISTANCE
    Sotomi, Y.
    Abe, K.
    Yoshida, J.
    Okamura, R.
    Iwakura, K.
    Masai, T.
    Fujii, K.
    INTENSIVE CARE MEDICINE, 2012, 38 : S268 - S268
  • [25] The ability of the Vigileo-FloTrac system to measure cardiac output and track cardiac output changes during one-lung ventilation
    Suehiro, Koichi
    Tanaka, Katsuaki
    Yamada, Tokuhiro
    Matsuura, Tadashi
    Mori, Takashi
    Funao, Tomoharu
    Nishikawa, Kiyonobu
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (03) : 333 - 339
  • [26] The ability of the Vigileo-FloTrac system to measure cardiac output and track cardiac output changes during one-lung ventilation
    Koichi Suehiro
    Katsuaki Tanaka
    Tokuhiro Yamada
    Tadashi Matsuura
    Takashi Mori
    Tomoharu Funao
    Kiyonobu Nishikawa
    Journal of Clinical Monitoring and Computing, 2015, 29 : 333 - 339
  • [27] Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study
    Oh, Chahyun
    Lee, Soomin
    Oh, Pyeonghwa
    Chung, Woosuk
    Ko, Youngkwon
    Yoon, Seok-Hwa
    Kim, Yoon-Hee
    Ji, Sung-Mi
    Hong, Boohwi
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (20)
  • [28] Precision of cardiac output measurement obtained with the fourth generation FloTrac-Vigileo and LiDCOrapid at the time of systemic vascular resistance variation
    Hagihara, S.
    Imabayashi, T.
    Yoshinaga, T.
    Hasegawa-Moriyama, M.
    Matsunaga, A.
    Kanmura, Y.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 41 - 42
  • [29] Disagreement in cardiac output measurements between fourth-generation FloTrac and critical care ultrasonography in patients with circulatory shock: a prospective observational study
    Kaufmann, Thomas
    Clement, Ramon P.
    Hiemstra, Bart
    Vos, Jaap Jan
    Scheeren, Thomas W. L.
    Keus, Frederik
    van der Horst, Iwan C. C.
    Koster, Geert
    Keus, Frederik
    van der Horst, Iwan C. C.
    Dieperink, Willem
    Bleijendaal, Roos
    Cawale, Yasmin F.
    Clement, Ramon P.
    Dijkhuizen, Devon
    Eck, Ruben J.
    Hiemstra, Bart
    Haker, Anja
    Hilbink, Casper D. H.
    Kaufmann, Thomas
    Klasen, Martiene
    Klaver, Manon
    Schokking, Laura J.
    Sikkens, Victor W.
    Vos, Madelon
    Woerlee, Justin
    Wiersema, Renske
    JOURNAL OF INTENSIVE CARE, 2019, 7 (1)
  • [30] Disagreement in cardiac output measurements between fourth-generation FloTrac and critical care ultrasonography in patients with circulatory shock: a prospective observational study
    Thomas Kaufmann
    Ramon P. Clement
    Bart Hiemstra
    Jaap Jan Vos
    Thomas W. L. Scheeren
    Frederik Keus
    Iwan C. C. van der Horst
    Journal of Intensive Care, 7