Durability of fluoropolymer and antibacterial finishes on woven surgical gown fabrics

被引:2
|
作者
Midha V.K. [1 ]
Vashisht R. [1 ]
Midha V. [1 ]
机构
[1] Department of Textile Technology, National Institute of Technology, Jalandhar
[2] Department of Chemical Engineering, National Institute of Technology, Jalandhar
关键词
Air permeability; Antibacterial; Fluoropolymer; Hydrostatic; Staphylococcus aureus; Water repellency;
D O I
10.1186/s40691-014-0012-7
中图分类号
学科分类号
摘要
Commercially available polyester, polyester-cotton and cotton plain woven fabrics of 150 g/m2 weight and cotton woven fabric samples of 200 g/m2 weight with plain, twill and satin weave were studied for their suitability as surgical gowns. Water repellent and anti bacterial finishes were applied in single bath using pad-dry-cure method with four concentration levels of these finishes. Liquid barrier properties of samples were analyzed by water impact penetration and hydrostatic pressure test. Parallel streak method was used to measure the antibacterial activity on the fabric samples with Staphylococcus aureus. The fabric samples were also analyzed for air permeability and stiffness. Optimum concentration level of fluoropolymer and antibacterial finishes for achieving desired liquid barrier and antibacterial properties were determined for each fabric samples. Fabric samples were subjected to repeated laundering cycles to evaluate the durability of finishes. It was observed that polyester fabric samples and 200 g/m2 cotton twill woven fabrics show highest level of liquid barrier protection of Level 2 according to Association for the Advancement of Medical Instrumentation (AAMI) standards, with 4% and 7% fluoropolymers. The fabrics maintain their barrier protection upto 20 laundering cycles, whereas 100% cotton fabric samples show minimal liquid barrier protection and do not provide Level 2 protection even at 4% and 7% fluoropolymer. © 2014, Midha et al.; licensee springer.
引用
收藏
相关论文
共 50 条
  • [31] An Experimental Study on EMI Shielding and Antibacterial Activity of Woven Fabrics Including Silver Nanocomposite Yarns
    Ilhan, Ilhami
    Ozkan, Ilkan
    Uslukul, Ozlem
    [J]. AATCC JOURNAL OF RESEARCH, 2024, 11 (02) : 124 - 138
  • [32] Study on the effect of plasma treatment of woven polyester fabrics with respect to nisin adsorption and antibacterial activity
    Kerkeni, Ahmed
    Behary, Nemeshwaree
    Dhulster, Pascal
    Chihib, Nour-Eddine
    Perwuelz, Anne
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2013, 129 (02) : 866 - 873
  • [33] Clostridioides difficile spores tolerate disinfection with sodium hypochlorite disinfectant and remain viable within surgical scrubs and gown fabrics
    Ahmed, Humaira
    Joshi, Lovleen Tina
    [J]. MICROBIOLOGY-SGM, 2023, 169 (11):
  • [34] IMPROVED DURABILITY OF TEMPERATURE-ADAPTABLE FINISHES FOR COTTON AND COTTON BLEND FABRICS BY INSITU CROSS-LINKING OF POLYETHYLENE GLYCOLS
    VIGO, TL
    BRUNO, JS
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 191 : 2 - CELL
  • [35] Improved durability of peroxide-based antibacterial agents on cotton/polyester and polyester fabrics.
    Vigo, TL
    D'Anna, GF
    Parikh, DV
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U178 - U178
  • [36] Effects of Hydrodynamic Diameter of Nanoparticles on Antibacterial Activity and Durability of Ag-treated Cotton Fabrics
    Mohammad Ehsan Momeni Heravi
    [J]. Fibers and Polymers, 2020, 21 : 1173 - 1179
  • [37] Stabiliby of Chitosan-stablized Nanosilver Solutions and Its Application for Antibacterial Durability of Cotton Fabrics
    Zhang Yu-Fei
    Li You-Liang
    Yao Yuan
    Li Wen-Yu
    Hu Qiao-Ling
    [J]. CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2012, 33 (08): : 1860 - 1865
  • [38] Effects of Hydrodynamic Diameter of Nanoparticles on Antibacterial Activity and Durability of Ag-treated Cotton Fabrics
    Heravi, Mohammad Ehsan Momeni
    [J]. FIBERS AND POLYMERS, 2020, 21 (06) : 1173 - 1179
  • [39] Interaction Between Fluoro Emulsion and Silane Quaternary Ammonium Salt on Dual Antibacterial and Hydrophobic Fabric of Surgical Gown
    Tuan-Anh Nguyen
    Vu Thuc Oanh Ta
    [J]. 7TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM (BME7): TRANSLATIONAL HEALTH SCIENCE AND TECHNOLOGY FOR DEVELOPING COUNTRIES, 2020, 69 : 663 - 667
  • [40] Multifunctional bioactive and improving the performance durability nanocoatings for finishing PET/CO woven fabrics by the sol-gel method
    Kowalczyk, Dorota
    Brzezinski, Stefan
    Kaminska, Irena
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2015, 649 : 387 - 393