Image quality and dose performance of 80 kV low dose scan protocol in high-pitch spiral coronary CT angiography: feasibility study

被引:0
|
作者
Dan Wang
Xiu-hua Hu
Shi-zheng Zhang
Run-ze Wu
Su-su Xie
Bin Chen
Qiao-wei Zhang
机构
[1] Zhejiang University,Department of Radiology, Sir Run Run Shaw Hospital, School of Medicine
[2] Sir Run Run Shaw Institute of Clinical Medicine of Zhejiang University,undefined
[3] Siemens Healthcare,undefined
关键词
High-pitch; Coronary CT angiography; Computed tomography; Dose; Image quality;
D O I
暂无
中图分类号
学科分类号
摘要
To investigate the image quality and dose performance of 80 kV high-pitch spiral (HPS) coronary CT angiography (CCTA). 106 patients consecutively enrolled into prospectively ECG-triggering HPS CCTA (pitch = 3.4) exam using kV/ref. mAs = 80/400, 100/370, and 120/370 when patient BMI was ≤22.5 (n = 40), between 22.5 and 27.5 (n = 53) and >27.5 kg/m² (n = 13). Image quality was assessed per-segment by two observers independently using a 4-point scale (1—excellent, 4—non-diagnosable). Image noise and signal-to-noise ratio (SNR), contrast-to-noise ratio were measured. Diagnostic image quality was obtained in 503 of 507, 687 of 693, 164 of 167 coronary segments in 80, 100, 120 kV groups without significant difference (P = 0.482). The proportions of segments with score 1–4 were not significantly different among three kV groups (all P > 0.05). Image noise were significantly higher in 80 kV group than 100 and 120 groups (P < 0.001), while SNR was not (P = 0.097). The effective dose of 80 kV group (0.36 ± 0.03 mSv) was significantly lower than that of 100 kV group (0.86 ± 0.08 mSv) and 120 kV group (1.77 ± 0.18 mSv). The mean ± SD of HR in all patients was 54.8 ± 5.1 bpm. 80 kV HPS CCTA is feasible for patient with BMI ≤ 22.5 kg/m² which can save 58% dose than 100 kV group, while maintain diagnosable image quality.
引用
收藏
页码:415 / 423
页数:8
相关论文
共 50 条
  • [1] Image quality and dose performance of 80 kV low dose scan protocol in high-pitch spiral coronary CT angiography: feasibility study
    Wang, Dan
    Hu, Xiu-hua
    Zhang, Shi-zheng
    Wu, Run-ze
    Xie, Su-su
    Chen, Bin
    Zhang, Qiao-wei
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (02): : 415 - 423
  • [2] Image quality and radiation exposure of low-dose protocols for coronary CT angiography: comparison of prospectively triggered axial scanning and high-pitch spiral CT
    Seltmann, M.
    Achenbach, S.
    Goroll, T.
    Marwan, M.
    Pflederer, T.
    Ropers, D.
    Lell, M.
    Anders, K.
    Uder, M.
    Daniel, W. G.
    EUROPEAN HEART JOURNAL, 2010, 31 : 293 - 293
  • [3] IMAGE QUALITY AND RADIATION EXPOSURE OF LOW-DOSE PROTOCOLS FOR CORONARY CT ANGIOGRAPHY: COMPARISON OF PROSPECTIVE AXIAL SCANNING AND HIGH-PITCH SPIRAL ACQUISITION
    Achenbach, Stephan
    Seltmann, Martin
    Pflederer, Tobias
    Marwan, Mohamed
    Ropers, Dieter
    Lell, Michael
    Anders, Katharina
    Kuettner, Axel
    Uder, Michael
    Daniel, Werner G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [4] Predictors of Image Quality in High-Pitch Coronary CT Angiography
    Stolzmann, Paul
    Goetti, Robert P.
    Maurovich-Horvat, Pal
    Hoffmann, Udo
    Flohr, Thomas G.
    Leschka, Sebastian
    Alkadhi, Hatem
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (04) : 851 - 858
  • [5] Radiation Dose and Image Quality of a High-Pitch Prospective Spiral First Approach in Coronary Computed Tomography Angiography (CCTA)
    Finck, Tom
    Klambauer, Konstantin
    Hendrich, Eva
    Will, Albrecht
    Martinoff, Stefan
    Hadamitzky, Martin
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (10)
  • [6] Routine chest and abdominal high-pitch CT: An alternative low dose protocol with preserved image quality
    Amacker, Nadja A.
    Mader, Caecilia
    Alkadhi, Hatem
    Leschka, Sebastian
    Frauenfelder, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : E392 - E397
  • [7] Detection of Coronary Artery Stenoses by Low-Dose, Prospectively ECG-Triggered, High-Pitch Spiral Coronary CT Angiography
    Achenbach, Stephan
    Goroll, Tobias
    Seltmann, Martin
    Pflederer, Tobias
    Anders, Katharina
    Ropers, Dieter
    Daniel, Werner G.
    Uder, Michael
    Lell, Michael
    Marwan, Mohamed
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) : 328 - 337
  • [8] Optimization of scanning protocols in low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography
    Kruk, M.
    Wardziak, L.
    Kowalewska, A.
    Demkow, M.
    Ruzyllo, W.
    Pregowski, J.
    Kepka, C.
    EUROPEAN HEART JOURNAL, 2013, 34 : 844 - 844
  • [9] Radiation Dose and Image Quality at High-Pitch CT Angiography of the Aorta: Intraindividual and Interindividual Comparisons With Conventional CT Angiography
    Apfaltrer, Paul
    Hanna, E. Lexworth
    Schoepf, U. Joseph
    Spears, J. Reid
    Schoenberg, Stefan O.
    Fink, Christian
    Vliegenthart, Rozemarijn
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1402 - 1409
  • [10] Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
    Zhuang, Y.
    Huang, W.
    Shi, Y.
    Bo, G.
    Lu, D.
    Zhang, J.
    Kong, D.
    Shit, Y.
    Wang, B.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (02): : 225 - 233