Nanorod arrays composed of zinc oxide modified with gold nanoparticles and glucose oxidase for enzymatic sensing of glucose

被引:1
|
作者
Yanguang Zhao
Xiaofei Fang
Xiaoqin Yan
Xiaohui Zhang
Zhuo Kang
Gong Zhang
Yue Zhang
机构
[1] University of Science and Technology Beijing,State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering
[2] University of Science and Technology Beijing,Key Laboratory of New Energy Materials and Technologies
来源
Microchimica Acta | 2015年 / 182卷
关键词
ZnO; Au nanoparticles; Electrochemical biosensor; Cyclic voltammetry; Glucose;
D O I
暂无
中图分类号
学科分类号
摘要
We report on an enzymatic electrochemical glucose biosensor based on the use of zinc oxide nanorods (ZnO NRs) modified with gold nanoparticles (Au-NPs) and arranged in the form of an array. The nanorods were obtained via a hydrothermal method, and the Au-NPs were synthesized by photo-reduction. The surface of the nanoarrays was then modified with Au-NPs via electrostatic self-assembly. GOx was immobilized onto the surface of Au-NPs modified ZnO nanoarrays by electrostatic adsorption. The performance of the resulting glucose biosensors were investigated by cyclic voltammetry and amperometry. Compared to biosensors based on ZnO nanoarrays without Au-NPs, the ones described here exhibit a higher sensitivity (43.7 nA cm−2 mM−1) and a lower Kapp,M (0.78 mM). It is obvious, therefore, that the Au-NPs play an important role with respect to the performance of this biosensor.
引用
收藏
页码:605 / 610
页数:5
相关论文
共 50 条
  • [21] Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode
    Wu, Bao-Yan
    Hou, Shi-Hua
    Yin, Feng
    Li, Jing
    Zhao, Zi-Xia
    Huang, Jia-Dong
    Chen, Qiang
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (06): : 838 - 844
  • [22] Three-dimensional hybrid graphene/nickel electrodes on zinc oxide nanorod arrays as non-enzymatic glucose biosensors
    Mazaheri, Mozhdeh
    Aashuri, Hossein
    Simchi, Abdolreza
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 251 : 462 - 471
  • [23] Glucose oxidase stabilized fluorescent gold nanoparticles as an ideal sensor matrix for dual mode sensing of glucose
    Muthurasu, A.
    Ganesh, V.
    RSC ADVANCES, 2016, 6 (09) : 7212 - 7223
  • [24] Novel glucose biosensor based on a glassy carbon electrode modified with hollow gold nanoparticles and glucose oxidase
    Wang, Weiqi
    Ying, Shuhua
    Zhang, Zhihui
    Huang, Shasheng
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 143 - 148
  • [25] Novel glucose biosensor based on a glassy carbon electrode modified with hollow gold nanoparticles and glucose oxidase
    Weiqi Wang
    Shuhua Ying
    Zhihui Zhang
    Shasheng Huang
    Microchimica Acta, 2011, 173 : 143 - 148
  • [26] A facile gold nanoparticles embeded hydrogel for non-enzymatic sensing of glucose
    Zhao, Jialin
    Hu, Xiaojun
    Huang, Xing
    Jin, Xin
    Koh, Kwangnak
    Chen, Hongxia
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 183
  • [27] Glucose biosensor based on glucose oxidase immobilized on branched TiO2 nanorod arrays
    Liu, S.
    Fu, D.
    ADVANCES IN ENERGY AND ENVIRONMENT RESEARCH, 2017, : 195 - 198
  • [28] Immobilization of glucose oxidase on gold nanoparticles modified Au electrode for the construction of biosensor
    Zhang, SX
    Wang, N
    Niu, YM
    Sun, CQ
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 109 (02) : 367 - 374
  • [29] Preparation and characterization of copper nanoparticles/zinc oxide composite modified electrode and its application to glucose sensing
    Kumar, S. Ashok
    Cheng, Hui-Wen
    Chen, Shen-Ming
    Wang, Sea-Fue
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2010, 30 (01): : 86 - 91
  • [30] Amperometric glucose-sensing electrode based on colloidal gold/glucose oxidase-modified glassy carbon
    Yabuki, S
    Mizutani, F
    DENKI KAGAKU, 1996, 64 (12): : 1256 - 1258