Study on the Influence of Close Distance Construction of Urban Tunnel on the Existing Station

被引:0
|
作者
Yang Zheng
Ke Wu
Jie Sun
Rong Chen
Yameng Li
Shifeng Yang
机构
[1] Shandong University,School of Civil Engineering
[2] Northeast Electric Power University (NEEPU),School of Civil Engineering and Architecture
[3] China Railway 14Th Bureau Group Tunnel Engineering Co.,undefined
[4] Ltd,undefined
关键词
Urban tunnels; Existing station; Tunnel-station-soil interaction; Numerical simulation;
D O I
暂无
中图分类号
学科分类号
摘要
In the construction of the tunnel passing through the existing structure at an ultra-close distance, the existing structure will produce obvious deformation. It is very important to understand the deformation characteristics of the existing upper structure at different positions, especially to ensure the safety of the upper structure and improve the effectiveness of tunnel construction. In this study, the double-line tunnels of Qingdao Metro Line 4 passing under the Cuobuling station were taken as the engineering background, and a detailed 3D numerical model was established. This study comprehensively considered the on-site construction process, including grouting hardening, stress release of the excavated rock mass, grouting pressure and so on. The influence of tunnel excavation on the ground settlement was compared with or without a station structure, and the result was fitted with an empirical formula. Finally, the deformation of the station structure due to the excavation of the double-line tunnels was analyzed. The results of the analysis were as follows: (1) In the presence of the station structure, the excavation of the tunnels had a significant impact on the surface settlement. (2) The settlement of the sidewall caused by the excavation of the left-line tunnel was greater than that of the right-line tunnel, and the settlement at the junction of the sidewall and the bottom plate was smaller than that at other positions of the sidewall. (3) Compared with the roof and middle slabs, the floor of the station was more susceptible to the influence of tunnel excavation. Overall, the research could provide guidance and reference for similar double-line tunnels through existing stations.
引用
收藏
页码:4765 / 4780
页数:15
相关论文
共 50 条
  • [41] Risk Assessment of an Existing Metro Tunnel in Close Proximity to New Shield Tunnels following Construction
    Xu, Yong
    Xia, Ming
    Zhang, Wei
    Li, Zheyu
    Zhang, Zhiqiang
    JOURNAL OF ENGINEERING, 2022, 2022
  • [42] Analysis on the Influence of Cross Tunnel Construction on the Deformation of the Existing High-Speed Railway Tunnel
    Pan W.
    Gao Z.
    Zheng C.
    Gong Z.
    Geotechnical and Geological Engineering, 2018, 36 (6) : 4001 - 4013
  • [43] Investigation on Existing Tunnel Response to Piles Construction: A Numerical Study
    Ayasrah, Mo'men
    Fattah, Mohammed Y.
    Hamood, Mohammed J.
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2023, 9 : 202 - 216
  • [44] Study on the Stability of Existing Tunnel Influenced By Adjacent Undercrossing Construction
    Song, Zhifei
    Yi, Fu
    Sung, Di
    PROCEEDINGS OF THE ADVANCES IN MATERIALS, MACHINERY, ELECTRICAL ENGINEERING (AMMEE 2017), 2017, 114 : 763 - 770
  • [45] Vibration analysis of the impact of the blasting construction of a power tunnel crossing underneath an existing subway station
    Gu, Zhimin
    Sun, Bingfeng
    Cui, Xiaoqing
    Guo, Hong
    World of Mining - Surface and Underground, 2020, 72 (02): : 86 - 92
  • [46] Effect of Vibration Caused by Blasting Construction of Undercrossing Tunnel on Comfort of Personnel in Existing Metro Station
    Sun B.
    Zhang D.
    Chen T.
    Fu H.
    Zhongguo Tiedao Kexue/China Railway Science, 2019, 40 (02): : 81 - 87
  • [47] Subway station construction parallelly below existing double-cell tunnel without clearance
    Su, Jie
    Yu, Lin
    Fang, Qian
    Niu, Xiaokai
    Yu, Junyu
    Zhang, Xu
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2024, 47 (02) : 192 - 203
  • [48] The influence of long distance overlapping shield tunnel construction on the formed tunnel and appropriate countermeasures
    Li, Zhaoping
    Wang, Kai
    Jiang, Houting
    Yang, Kang
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2020, 53 : 174 - 179
  • [49] Research on influence and monitoring of shield tunnel obliquely crossing beneath existing subway station
    Beijing Municipal Engineering Research Institute, Beijing 100037, China
    不详
    Yanshilixue Yu Gongcheng Xuebao, 2009, SUPPL. 1 (3186-3192):
  • [50] Study on Construction Control Measures of Shield Tunnel Overpassing Existing Tunnel in Sandy Silt
    Wang, Yahui
    Liu, Yan
    Liu, Junyan
    Zhang, Liangliang
    PROCEEDINGS OF GEOSHANGHAI 2018 INTERNATIONAL CONFERENCE: TUNNELLING AND UNDERGROUND CONSTRUCTION, 2018, : 567 - 575