Efficacy of Code Provisions for Seismic Design of Asymmetric RC Building

被引:0
|
作者
Balakrishnan B. [1 ]
Sarkar P. [2 ]
机构
[1] Department of Civil Engineering, Indian Institute of Technology Madras, Chennai
[2] Department of Civil Engineering, National Institute of Technology, Rourkela, 769 008, Orissa
关键词
Asymmetric building; Non-linear dynamic analysis; Plastic hinge; Pushover analysis; Reinforced concrete; Torsion;
D O I
10.1007/s40030-016-0156-0
中图分类号
学科分类号
摘要
The earthquake resistant design code in India, IS: 1893, has been revised in 2002 to include provisions for torsional irregularity in asymmetric buildings. In line with other international code, IS 1893: 2002 requires estimating the design eccentricity from static and accidental eccentricity. The present study attempts to evaluate the effectiveness of the design code requirements for designing torsionally irregular asymmetric buildings. Two similar asymmetric buildings designed considering and ignoring code requirement has been considered for this study. Nonlinear static and dynamic analyses are performed on these buildings to realize the difference in their behaviour and it is found that the plan asymmetry in the building makes it non-ductile even after design with code provisions. Code criterion for plan asymmetry tends to improve the strength of members but this study indicates that changing the stiffness distribution to reduce eccentricity may lead to a preferred mode of failure. © 2016, The Institution of Engineers (India).
引用
收藏
页码:111 / 120
页数:9
相关论文
共 50 条
  • [1] Evolution of seismic design provisions in the National building code of Canada
    Mitchell, Denis
    Paultre, Patrick
    Tinawi, Rene
    Saatcioglu, Murat
    Tremblay, Robert
    Elwood, Kenneth
    Adams, John
    DeVall, Ronald
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2010, 37 (09) : 1157 - 1170
  • [2] The seismic design provisions of the 2003 Edition of the International Building Code
    Ghosh, SK
    Dowty, S
    PCI JOURNAL, 2003, 48 (03): : 92 - 95
  • [3] SEISMIC CODE PROVISIONS FOR ASYMMETRIC STRUCTURES - A REEVALUATION
    RUTENBERG, A
    PEKAU, OA
    ENGINEERING STRUCTURES, 1987, 9 (04) : 255 - 264
  • [4] Experimental validation of seismic code provisions for RC columns
    Vintzileou, Elizabeth
    Tassios, T. P.
    Chronopoulos, M.
    ENGINEERING STRUCTURES, 2007, 29 (06) : 1153 - 1164
  • [5] Seismic shear design of RC bridge piers - Part I: Review of code provisions
    Goswami, Rupen
    Murty, C.V.R.
    Indian Concr J, 6 (1127-1133):
  • [7] Background to some of the seismic design provisions of the 2015 National Building Code of Canada
    Humar, Jagmohan
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2015, 42 (11) : 940 - 952
  • [8] EVALUATION OF SEISMIC TORSIONAL PROVISIONS IN UNIFORM BUILDING CODE
    WONG, CM
    TSO, WK
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (10): : 1436 - 1442
  • [9] Evaluation of seismic torsional provisions in uniform building code
    Wong, C.M.
    Tso, W.K.
    Journal of structural engineering New York, N.Y., 1995, 121 (10): : 1436 - 1442
  • [10] SEISMIC CODE PROVISIONS FOR ASYMMETRIC STRUCTURES - LOW PERIOD SYSTEMS
    RUTENBERG, A
    PEKAU, OA
    ENGINEERING STRUCTURES, 1989, 11 (02) : 92 - 96