Thermal Conductivity of the Refrigerant Mixtures R404A, R407C, R410A, and R507A

被引:0
|
作者
V. Z. Geller
B. V. Nemzer
U. V. Cheremnykh
机构
[1] Thermophysics Research Center,
[2] Odessa State Academy of Refrigeration,undefined
来源
关键词
hot-wire method; refrigerants; R404A; R407C; R410A; R507A; thermal conductivity; vapor phase;
D O I
暂无
中图分类号
学科分类号
摘要
New thermal conductivity data of the refrigerant mixtures R404A, R407C, R410A, and R507C are presented. For all these refrigerants, the thermal conductivity was measured in the vapor phase at atmospheric pressure over a temperature range from 250 to 400 K and also at moderate pressures. A modified steady-state hot-wire method was used for these measurements. The cumulative correction for end effects, eccentricity of the wire, and radiation heat transfer did not exceed 2%. Calculated uncertainties in experimental thermal conductivity are, in general, less than ±1.5%. All available literature thermal conductivity data for R404A, R407C, R410A, and R507C were evaluated to identify the most accurate data on which to base the thermal conductivity model. The thermal conductivity is modeled with the residual concept. In this representation, the thermal conductivity was composed of two contributions: a dilute gas term which is a function only of temperature and a residual term which is a function only of density. The models cover a wide range of conditions except for the region of the thermal conductivity critical enhancement. The resulting correlations are applicable for the thermal conductivity of dilute gas, superheated vapor, and saturated liquid and vapor far away from the critical point. Comparisons are made for all available literature data.
引用
收藏
页码:1035 / 1043
页数:8
相关论文
共 50 条
  • [21] Overview of low GWP mixtures for the replacement of HFC refrigerants: R134a, R404A and R410A
    Heredia-Aricapa, Y.
    Belman-Flores, J. M.
    Mota-Babiloni, A.
    Serrano-Arellano, J.
    Garcia-Pabon, Juan J.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 111 : 113 - 123
  • [22] Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A
    Arora, Akhilesh
    Kaushik, S. C.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (06): : 998 - 1005
  • [23] R410A/R404A/R407C在T型翅内螺纹水平管外的降膜蒸发换热研究
    苏肖雅
    欧阳新萍
    热能动力工程, 2019, 34 (02) : 88 - 93
  • [24] A comparative performance study of a direct expansion geothermal evaporator using R410A and R407C as refrigerant alternatives to R22
    Fannou, Jean-Louis Comlan
    Rousseau, Clement
    Lamarche, Louis
    Kajl, Stanislaw
    APPLIED THERMAL ENGINEERING, 2015, 82 : 306 - 317
  • [25] Flow-boiling of R22, R134a, R507, R404A and R410A inside a smooth horizontal tube
    Greco, A
    Vanoli, GP
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (06): : 872 - 880
  • [26] Pseudo-pure fluid equations of state for the refrigerant blends R-410A, R-404A, R-507A, and R-407C
    Lemmon, EW
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2003, 24 (04) : 991 - 1006
  • [27] Pseudo-Pure Fluid Equations of State for the Refrigerant Blends R-410A, R-404A, R-507A, and R-407C
    E. W. Lemmon
    International Journal of Thermophysics, 2003, 24 : 991 - 1006
  • [28] R410A和R407C饱和液相运动黏度测量
    张颖
    何茂刚
    刘洋
    工程热物理学报, 2011, 32 (06) : 925 - 928
  • [29] Partial condensation of R407C and R410A refrigerants inside a plate heat exchanger
    Mancin, Simone
    Del Col, Davide
    Rossetto, Luisa
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 36 : 149 - 157
  • [30] Experimental investigation of R407C and R410A flow through electronic expansion valve
    Ye Qifang
    Chen Jiangping
    Chen Zhijiu
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (05) : 1624 - 1630