Stent expansion evaluated by optical coherence tomography and subsequent outcomes

被引:0
|
作者
Bom Lee
Teklay Gebrehaweria Baraki
Byung Gyu Kim
Yong-Joon Lee
Seung-Jun Lee
Sung-Jin Hong
Chul-Min Ahn
Dong-Ho Shin
Byeong-Keuk Kim
Young-Guk Ko
Donghoon Choi
Myeong-Ki Hong
Yangsoo Jang
Jung-Sun Kim
机构
[1] Yonsei University College of Medicine,Division of Cardiology, Department of Internal Medicine, Severance Cardiovascular Hospital
[2] Inje University College of Medicine,Division of Cardiology, Department of Internal Medicine, Sanggye Paik Hospital
[3] CHA University,Division of Cardiology, Department of Internal Medicine, CHA Bundang Medical Center
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Regarding stent expansion indices, previous optical coherence tomography (OCT) studies have shown minimal stent area (MSA) to be most predictive of adverse events. We sought to evaluate the impact of various stent expansion and apposition indices by post-stent OCT on clinical outcomes and find OCT-defined optimal stent implantation criteria. A total of 1071 patients with 1123 native coronary artery lesions treated with new-generation drug-eluting stents with OCT guidance and final post-stent OCT analysis were included. Several stent expansion indices (MSA, MSA/average reference lumen area, MSA/distal reference lumen area, mean stent expansion, and stent expansion by linear model [stent volume/adaptive reference lumen volume]) were evaluated for their association with device-oriented clinical endpoints (DoCE) including cardiac death, target vessel-related myocardial infarction (MI) or stent thrombosis, and target lesion revascularization. MSA was negatively correlated with the risk of DoCE (hazard ratio [HR] 0.80 [0.68‒0.94]). However, stent expansion by linear model representing the overall volumetric stent expansion was associated with greater risk of DoCE (HR 1.02 [1.00‒1.04]). As categorical criteria, MSA < 5.0 mm2 (HR 3.90 [1.99‒7.65]), MSA/distal reference lumen area < 90% (HR 2.16 [1.12‒4.19]), and stent expansion by linear model ≥ 65.0% (HR 1.95 [1.03‒3.89]) were independently associated with DoCE. This OCT study highlights the importance of sufficient stent expansion to achieve adequate, absolute, and relative MSA criteria for improving clinical outcome. It also emphasises that overall volumetric excessive stent expansion may have detrimental effects.
引用
收藏
相关论文
共 50 条
  • [31] Reproducibility of quantitative optical coherence tomography for stent analysis
    Lopez, N. Gonzalo
    Garcia-Garcia, H. M.
    Serruys, P. W.
    Commissaris, K.
    Bezerra, H.
    Gobbens, P.
    Costa, M.
    Regar, E.
    EUROPEAN HEART JOURNAL, 2009, 30 : 675 - 675
  • [32] Coronary Stent Reconstruction in Intravascular Optical Coherence Tomography
    Liu Tiegen
    Tao Kuiyuan
    Ding Zhenyang
    Liu Kun
    Jiang Junfeng
    Lu Ruixiang
    Huang Jinyu
    Zhou Liang
    Gao Beibei
    Tong Guoxin
    Cao Ping
    Deng Peitao
    Xu Keyong
    Peng Chengqing
    Wan Tong
    Ou Guikang
    ACTA OPTICA SINICA, 2021, 41 (04)
  • [33] STENT SIZING USING OPTICAL COHERENCE TOMOGRAPHY IMAGING
    Rai, H.
    Raeber, L.
    Leister, D. M.
    Nef, H.
    Alfonso, F.
    Byrne, R. A.
    Kastrati, A.
    Joner, M.
    HEART, 2022, 108 : A9 - A10
  • [34] An accidentally crushed stent identified by optical coherence tomography
    Al-Bawardy, Rasha
    Thomas, Sunu
    Cameron, Duke
    Jang, Ik-Kyung
    CORONARY ARTERY DISEASE, 2018, 29 (05) : 438 - 440
  • [35] Stent strut detection in intravascular optical coherence tomography
    Carreira, Maria J.
    Gonzalez, Y. M.
    Penedo, M. G.
    Trillo, R.
    PROCEEDINGS OF THE 2013 8TH IBERIAN CONFERENCE ON INFORMATION SYSTEMS AND TECHNOLOGIES (CISTI 2013), 2013,
  • [36] Stent accordion phenomenon visualized with optical coherence tomography
    Cuenza, Lucky R.
    Yeo, Khung Keong
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2017, 7 (06) : 640 - 642
  • [37] Unusual stent fracture: diagnosis with optical coherence tomography
    Bennett, Johan
    De Cock, Dries
    Hiltrop, Nick
    Adriaenssens, Tom
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2016, 17 : E231 - E232
  • [38] Reproducibility Of Quantitative Optical Coherence Tomography For Stent Analysis
    Gonzalo, Nieves
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    Commissaris, Koen H.
    Bezerra, Hiram
    Gobbens, Pierre
    Costa, Marco
    Regar, Evelyn
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 55D - 56D
  • [39] Role of Optical Coherence Tomography in the Assessment of Stent Deformation
    Abdel-Hadi, Hani
    Shah, Ashish H.
    Dzavik, Vladimir
    CANADIAN JOURNAL OF CARDIOLOGY, 2016, 32 (03) : 396.e1 - 396.e2
  • [40] Optical Coherence Tomography Findings in Patients With Stent Thrombosis
    Cuesta, Javier
    Rivero, Fernando
    Bastante, Teresa
    Garcia-Guimaraes, Marcos
    Antuna, Paula
    Alvarado, Teresa
    Navarrete, Gonzalo
    Benedicto, Amparo
    Alfonso, Fernando
    REVISTA ESPANOLA DE CARDIOLOGIA, 2017, 70 (12): : 1050 - 1058