Morphological changes of the pivot bearings in the Gyro Pump C1E3 after clinical use

被引:0
|
作者
Takami Y. [1 ]
Ina H. [1 ]
Ohara Y. [2 ]
机构
[1] Division of Cardiovascular Surgery, Kasugai Municipal Hospital, Kasugai 486-8510
[2] Department of Thoracic Surgery, Nagoya University, School of Medicine, Nagoya
关键词
Cardiopulmonary bypass; Centrifugal pump; Morphological change; Pivot;
D O I
10.1007/BF02481427
中图分类号
学科分类号
摘要
The Gyro Pump C1E3 incorporates a double-pivot bearing system as a completely sealless centrifugal pump. The male pivot is made of alumina ceramic, and the female is made of polyethylene. Therefore, the durability of this pump depends upon morphological changes of the female polyethylene pivots, which we examined after clinical usage in the present study. We examined 30 pumps, which were used for cardiopulmonary bypass (CPB), in terms of weight, depth, and surface roughness of the female polyethylene pivots. To determine changes caused by clinical use, we also examined 10 pumps of the same lot numbers with the pumps clinically used and stocked in the factory. There were no significant changes in weight of top and bottom pivots. Also, there was no significant difference in depth and surface roughness of the top pivots. However, there was a significant increase in depth and a decrease in surface roughness of the bottom pivots from clinical use. The results revealed that the bottom pivot, rather than the top pivot, is subject to mechanical deformation by clinical use of the Gyro Pump for CPB. Since morphological changes of the bottom pivot may result from spinning of the impeller at the bottom contact phase, the magnetic coupling distance may need to be increased to obtain more stable spinning of the impeller in a routine CPB.
引用
收藏
页码:156 / 160
页数:4
相关论文
共 50 条
  • [1] Evaluation of the wear of the pivot bearing in the Gyro C1E3 pump
    Makinouchi, K
    Nakazawa, T
    Takami, Y
    Takatani, S
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1996, 20 (06) : 523 - 528
  • [2] A clinical use of the Kyocera Gyro C1E3 centrifugal pump
    Hata, M
    Shiono, M
    Orime, Y
    Yagi, S
    Yamamoto, T
    Okumura, H
    Kimura, S
    Sezai, A
    Kashiwazaki, S
    Choh, S
    Negishi, N
    Sezai, Y
    Matsui, T
    Suzuki, M
    Nakata, K
    Nosé, Y
    [J]. ARTIFICIAL ORGANS, 2000, 24 (01) : 76 - 78
  • [3] Material of the double pivot bearing system in the Gyro C1E3 centrifugal pump
    Takami, Y
    Nakazawa, T
    Makinouchi, K
    Benkowski, R
    Glueck, J
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1997, 21 (02) : 143 - 147
  • [4] Clinical evaluation of the Gyro Pump C1e3 as a cardiopulmonary bypass pump
    Orime, Y
    Shiono, M
    Yagi, S
    Yamamoto, T
    Okumura, H
    Kimura, S
    Hata, M
    Sezai, A
    Kashiwazaki, S
    Choh, S
    Negishi, N
    Sezai, Y
    Matsui, T
    Suzuki, M
    [J]. ASAIO JOURNAL, 2000, 46 (01) : 128 - 133
  • [5] Hemolytic characteristics of a pivot bearing supported gyro centrifugal pump (C1E3) simulating various clinical applications
    Takami, Y
    Makinouchi, K
    Nakazawa, T
    Benkowski, R
    Glueck, J
    Ohara, Y
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1996, 20 (09) : 1042 - 1049
  • [6] Hemolytic characteristics of a pivot bearing supported Gyro centrifugal pump (C1E3) simulating various clinical applications
    Department of Surgery, Baylor College of Medicine, Houston, TX, United States
    不详
    [J]. ARTIF. ORGANS, 9 (1042-1049):
  • [8] Pump power loss and heat generation in a pivot bearing-supported gyro centrifugal pump (C1E3)
    Takami, Y
    Nakazawa, T
    Makinouchi, K
    Glueck, J
    Ohara, Y
    Benkowski, RJ
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1996, 20 (07) : 794 - 797
  • [9] Effect of surface roughness on hemolysis in a pivot bearing supported gyro centrifugal pump (C1E3)
    Takami, Y
    Makinouchi, K
    Nakazawa, T
    Glueck, J
    Benkowski, R
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1996, 20 (11) : 1155 - 1161
  • [10] The hemolysis test of the Gyro C1E3 pump in pulsatile mode
    Department of Surgery, Baylor College of Medicine, Houston, TX, United States
    不详
    [J]. ARTIF. ORGANS, 7 (675-679):