Intraoperative imaging with the ISO C 3D [Intraoperative bildgebung mit dem ISO C 3D]

被引:0
|
作者
Wich M. [1 ,2 ]
Spranger N. [1 ]
Ekkernkamp A. [1 ]
机构
[1] Klin. F. Unfall- W., Unfallkrankenhaus Berlin
[2] Klin. F. Unfall- W., Unfallkrankenhaus Berlin, 12683 Berlin
来源
Der Chirurg | 2004年 / 75卷 / 10期
关键词
C-arm; CT-scan; Intraoperative MPR; ISO C [!sup]3D[!/sup; Orthopedic surgery;
D O I
10.1007/s00104-004-0953-2
中图分类号
学科分类号
摘要
Computed tomography (CT) scanning is the gold standard for displaying and visualizing complex anatomic structures such as the calcaneus, pelvis, and spine, etc. In orthopedic surgery CT scanning is unfortunately not available in the OR where it would be highly effective if scans could be done prior to wound closure. The reasons are high costs, need for constructional changes in the OR, and additional staff (radiologic technologist), etc. For the first time the ISO C 3D enables the surgeon to generate multiplanar reconstruction (MPR) pictures during surgery within an acceptable time frame at a reasonable price with a familiar instrument (a modified C-arm). Since February 2001 we have been able to use the ISO C 3D in our hospital and meanwhile we have scanned 442 surgical sites including the calcaneus, cervical spine, and acetabulum, etc. The intraoperative scans revealed fracture gaps and steps, unsatisfactory fragment alignment, or incorrectly positioned implants, leading to an overall revision rate of 7.3% The ISO C 3D is a first step towards a new future for bone visualization. The next steps will bring an increase in scan area and resolution, and the high-contrast pictures will be replaced by ones very similar to modern CT slices showing certain soft tissue structures.
引用
收藏
页码:982 / 987
页数:5
相关论文
共 50 条
  • [21] C-OnSite® for intraoperative 3D control of pedicular screw positions
    Sven Rainer Kantelhardt
    Naureen Keric
    Jens Conrad
    Amr Nimer
    Raymund Woo
    Laura Varich
    Alf Giese
    [J]. Acta Neurochirurgica, 2014, 156 : 1799 - 1805
  • [22] C-OnSiteA® for intraoperative 3D control of pedicular screw positions
    Kantelhardt, Sven Rainer
    Keric, Naureen
    Conrad, Jens
    Nimer, Amr
    Woo, Raymund
    Varich, Laura
    Giese, Alf
    [J]. ACTA NEUROCHIRURGICA, 2014, 156 (09) : 1799 - 1805
  • [23] Die intraoperative 3D-C-Bogen-AnwendungState of the artIntraoperative 3D C-arm imagingState of the art
    J. von Recum
    K. Wendl
    B. Vock
    P.A. Grützner
    J. Franke
    [J]. Der Unfallchirurg, 2012, 115 (3): : 196 - 201
  • [24] Intraoperative Computed Tomography Versus 3D C-Arm Imaging for Navigated Spinal Instrumentation
    Hecht, Nils
    Yassin, Hadya
    Czabanka, Marcus
    Foehre, Bettina
    Arden, Klaus
    Liebig, Thomas
    Vajkoczy, Peter
    [J]. SPINE, 2018, 43 (05) : 370 - 377
  • [25] Intraoperative histology: Lightning 3D histopathology
    Rory M. Power
    Jan Huisken
    [J]. Nature Biomedical Engineering, 1
  • [26] Intraoperative 3D transoesophageal valvular evaluation
    T Anguseva
    I Milev
    E Idoski
    Z Mitrev
    [J]. Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [27] Intraoperative 3D fluoroscopy in stereotactic surgery
    Lutz Weise
    S. Eibach
    V. Seifert
    M. Setzer
    [J]. Acta Neurochirurgica, 2012, 154 : 815 - 821
  • [28] Intraoperative 3D fluoroscopy in stereotactic surgery
    Weise, Lutz
    Eibach, S.
    Seifert, V.
    Setzer, M.
    [J]. ACTA NEUROCHIRURGICA, 2012, 154 (05) : 815 - 821
  • [29] Intraoperative 3d transoesophageal evaluation of the heart
    Nikola, Anguseva Tanja
    Kostadin, Mitrev Zan
    [J]. CARDIOVASCULAR DRUGS AND THERAPY, 2007, 21 : S87 - S87
  • [30] ISO-C 3D accuracy-control and usefullness at calcanues osteosynthesis
    Kendoff, D
    Geerling, J
    Richter, M
    Hüfner, T
    Citak, M
    Krettek, C
    Kfuri, M
    [J]. PERSPECTIVE IN IMAGE-GUIDED SURGERY, 2004, : 133 - 136