A Highly Sensitive and Selective Method for the Determination of an Iodate in Table-salt Samples Using Malachite Green-based Spectrophotometry
被引:0
|
作者:
Mongkol Konkayan
论文数: 0引用数: 0
h-index: 0
机构:Khon Kaen University,Materials Chemistry' Research Center, Department of Chemistry' and Center of Excellence for Innovation in Chemistry, Faculty of Science
Mongkol Konkayan
Nunticha Limchoowong
论文数: 0引用数: 0
h-index: 0
机构:Khon Kaen University,Materials Chemistry' Research Center, Department of Chemistry' and Center of Excellence for Innovation in Chemistry, Faculty of Science
Nunticha Limchoowong
Phitchan Sricharoen
论文数: 0引用数: 0
h-index: 0
机构:Khon Kaen University,Materials Chemistry' Research Center, Department of Chemistry' and Center of Excellence for Innovation in Chemistry, Faculty of Science
Phitchan Sricharoen
Saksit Chanthai
论文数: 0引用数: 0
h-index: 0
机构:Khon Kaen University,Materials Chemistry' Research Center, Department of Chemistry' and Center of Excellence for Innovation in Chemistry, Faculty of Science
Saksit Chanthai
机构:
[1] Khon Kaen University,Materials Chemistry' Research Center, Department of Chemistry' and Center of Excellence for Innovation in Chemistry, Faculty of Science
A simple, rapid, and sensitive malachite green-based spectrophotometric method for the selective trace determination of an iodate has been developed and presented for the first time. The reaction mixture was specifically involved in the liberation of iodine in the presence of an excess of iodide in an acidic condition following an instantaneous reaction between the liberated iodine and malachite green dye. The optimum condition was obtained with a buffer solution pH of 5.2 in the presence of 40 mg L−1 potassium iodide and 1.5 × 10−5 M malachite green for a 5-min incubation time. The iodate contents in some table-salt samples were in the range of 26 to 45 mg kg−1, while those of drinking water, tap water, canal water, and seawater samples were not detectable (< 96 ng mL−1 of limits of detection, LOQ) with their satisfied method of recoveries of between 93 and 108%. The results agreed with those obtained using ICP-OES for comparison.
Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, College of Chemical and Chemistry Engineering, Southwest University, Chongqing
论文数: 0引用数: 0
h-index: 0
Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, College of Chemical and Chemistry Engineering, Southwest University, Chongqing
机构:
Korea Inst Sci & Technol, Green City Technol Inst, Seoul, South Korea
Korea Univ, Dept Chem, Seoul, South KoreaKorea Inst Sci & Technol, Green City Technol Inst, Seoul, South Korea
Kim, Kyung Min
Nam, Yun-Sik
论文数: 0引用数: 0
h-index: 0
机构:
Korea Inst Sci & Technol, Adv Anal Ctr, Seoul, South KoreaKorea Inst Sci & Technol, Green City Technol Inst, Seoul, South Korea
Nam, Yun-Sik
Lee, Yeonhee
论文数: 0引用数: 0
h-index: 0
机构:
Korea Inst Sci & Technol, Adv Anal Ctr, Seoul, South KoreaKorea Inst Sci & Technol, Green City Technol Inst, Seoul, South Korea
Lee, Yeonhee
Lee, Kang-Bong
论文数: 0引用数: 0
h-index: 0
机构:
Korea Inst Sci & Technol, Green City Technol Inst, Seoul, South KoreaKorea Inst Sci & Technol, Green City Technol Inst, Seoul, South Korea