Assessment of right ventricular function with 320-slice volume cardiac CT: comparison with cardiac magnetic resonance imaging

被引:0
|
作者
Xiaoyong Huang
Xin Pu
Ruiyu Dou
Xi Guo
Zixu Yan
Zhaoqi Zhang
Meng Li
Hong Jiang
Biao Lu
机构
[1] Anzhen Hospital,Department of Radiology
[2] affiliated to the Capital Medicine of University,undefined
关键词
Right ventricular function; Computed tomography; Magnetic resonance; Comparative study; Image processing;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the accuracy and feasibility of right ventricular function parameters measurement using 320-slice volume cardiac CT. Retrospective analysis of 50 consecutive patients (23 men, 27 women) with suspected pulmonary diseases was performed in electrocardiogram (ECG)-gated cardiac CT and cardiac magnetic resonance (CMR). Parameters including right ventricular end-diastolic volume (RVEDV), right ventricular end- systolic volume (RVESV), right ventricular stroke volume (RVSV), right ventricular cardiac output (RVCO), and right ventricular ejection fraction (RVEF) were semi-automatically and separately calculated from both CT and CMR data. Significant difference between measurements was measured by paired t test and two-variable linear regression analysis with Pearson’s correlation coefficient. Bland–Altman analysis was performed in each pair of parameters. There was little variability between the measurements by the two observers (kappa = 0.895–0.980, P < 0.05). There was good correlation between all parameters obtained by CT and CMR (P < 0.001): RVEDV (108.5 ± 21.9 ml, 113.5 ± 24.8 ml, r = 0.944), RVESV (69.8 ± 33.4 ml, 73.2 ± 35.4 ml, r = 0.972), RVSV (39.0 ± 13.2 ml, 40.2 ± 13.3 ml, r = 0.977), RVCO (2.6 ± 0.7 l, 2.6 ± 0.7 l. r = 0.958), RVEF (38.8 ± 19.1 %, 39.1 ± 19.3 %, r = 0.990), and there was no significant difference between CT and CMR measurements in RVEF (n = 50, t = −0.677, P > 0.05). 320-slice volume cardiac CT is an accurate non-invasive technique to evaluate RV function.
引用
收藏
页码:87 / 92
页数:5
相关论文
共 50 条
  • [1] Assessment of right ventricular function with 320-slice volume cardiac CT: comparison with cardiac magnetic resonance imaging
    Huang, Xiaoyong
    Pu, Xin
    Dou, Ruiyu
    Guo, Xi
    Yan, Zixu
    Zhang, Zhaoqi
    Li, Meng
    Jiang, Hong
    Lu, Biao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 : 87 - 92
  • [2] Comparison of echocardiographic parameters with cardiac magnetic resonance imaging in the assessment of right ventricular function
    Agasthi, Pradyumna
    Chao, Chieh-Ju
    Siegel, Robert J.
    Pujari, Sai Harika
    Mookadam, Farouk
    Venepally, Nithin R.
    Wang, Panwen
    Ashraf, Hasan
    Marcotte, Francois
    Brown, Lisa
    Semkiv, Oksana I.
    Fath, Ayman R.
    Allam, Mohamed N. A.
    Jokerst, Clinton E.
    Arsanjani, Reza
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (11): : 1792 - 1802
  • [3] Assessment of left atrial volume and function in patients with permanent atrial fibrillation: comparison of cardiac magnetic resonance imaging, 320-slice multi-detector computed tomography, and transthoracic echocardiography
    Agner, Bue F. Ross
    Kuhl, Jorgen Tobias
    Linde, Jesper James
    Kofoed, Klaus F.
    Akeson, Per
    Rasmussen, Bo V.
    Jensen, Gorm B.
    Dixen, Ulrik
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (05) : 532 - 540
  • [4] Assessment of ventricular function and mass by cardiac magnetic resonance imaging
    Alfakih, K
    Reid, S
    Jones, T
    Sivananthan, M
    EUROPEAN RADIOLOGY, 2004, 14 (10) : 1813 - 1822
  • [5] Assessment of ventricular function and mass by cardiac magnetic resonance imaging
    Khaled Alfakih
    Scott Reid
    Tim Jones
    Mohan Sivananthan
    European Radiology, 2004, 14 : 1813 - 1822
  • [6] Performance of Automated Software in the Assessment of Segmental Left Ventricular Function in Cardiac CT: Comparison with Cardiac Magnetic Resonance
    Rui Wang
    Felix G. Meinel
    U. Joseph Schoepf
    Christian Canstein
    James V. Spearman
    Carlo N. De Cecco
    European Radiology, 2015, 25 : 3560 - 3566
  • [7] Performance of Automated Software in the Assessment of Segmental Left Ventricular Function in Cardiac CT: Comparison with Cardiac Magnetic Resonance
    Wang, Rui
    Meinel, Felix G.
    Schoepf, U. Joseph
    Canstein, Christian
    Spearman, James V.
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2015, 25 (12) : 3560 - 3566
  • [8] Cardiac Magnetic Resonance Imaging for Right Ventricular Disease
    Tong, M. M. P.
    Wong, K. T.
    HONG KONG JOURNAL OF RADIOLOGY, 2018, 21 (04): : 228 - 240
  • [9] Comparison of Left Ventricular Function and Mass Assessment on Everyday Echocardiography and Cardiac Magnetic Resonance Imaging
    Lee, Mirae
    Byeon, Kyeongmin
    Kim, Eun Young
    Yang, Jeong Hoon
    Lee, Sungho
    Park, Sung Beom
    Chung, Seungmin
    Park, Jeong-Euy
    Choe, Yeon Hyeon
    Lee, Sang-Chol
    CIRCULATION, 2010, 122 (21)
  • [10] Cardiac CT for Measurement of Right Ventricular Volume and Function in Comparison with Cardiac MRI: A Meta-Analysis
    Kim, Jin Young
    Suh, Young Joo
    Han, Kyunghwa
    Kim, Young Jin
    Choi, Byoung Wook
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (04) : 450 - 461