Assessment of left atrial volume and function in patients with permanent atrial fibrillation: comparison of cardiac magnetic resonance imaging, 320-slice multi-detector computed tomography, and transthoracic echocardiography

被引:65
|
作者
Agner, Bue F. Ross [1 ]
Kuhl, Jorgen Tobias [2 ]
Linde, Jesper James [1 ]
Kofoed, Klaus F. [2 ,3 ]
Akeson, Per [4 ]
Rasmussen, Bo V. [1 ]
Jensen, Gorm B. [1 ]
Dixen, Ulrik [1 ]
机构
[1] Hvidovre Univ Hosp, Dept Cardiol, DK-2650 Copenhagen, Denmark
[2] Univ Copenhagen, Rigshosp, Ctr Heart, Dept Cardiol, DK-2100 Copenhagen, Denmark
[3] Univ Copenhagen, Rigshosp, Ctr Diagnost, Dept Radiol, DK-2100 Copenhagen, Denmark
[4] Hvidovre Univ Hosp, Danish Res Ctr Magnet Resonance, Copenhagen, Denmark
关键词
atrial fibrillation; cardiac magnetic resonance; transthoracic echocardiography; multi-detector computed tomography; left atrial volume; left atrial function; PULMONARY VEIN ISOLATION; 2-DIMENSIONAL ECHOCARDIOGRAPHY; VENTRICULAR VOLUME; RECURRENCE; PERSISTENT; REPRODUCIBILITY; VALIDATION; PREDICTORS; ABLATION; RISK;
D O I
10.1093/ehjci/jet239
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Atrial fibrillation (AF) is a common cardiac arrhythmia that is associated with substantial morbidity and mortality. AF is associated with enlargement of the left atrium (LA), and the LA volume has important prognostic implications for the disease. The objective of the study was to determine how measurements of LA volume and function obtained by transthoracic echocardiography (TTE), cardiac magnetic resonance (CMR), and 320-slice multi-detector computed tomography (MDCT) correlate in patients with permanent AF. Thirty-four patients with permanent AF participated in the study. TTE, CMR, and 320-slice MDCT imaging procedures were performed within 7 4 days. 320-slice MDCT overestimated maximal LA volume (LAmax) and minimal LA volume (LAmin) compared with CMR (LAmax: 80 vs. 73 mL/m(2), P = 0.0017; LAmin: 69 vs. 64 mL/m(2), P = 0.0217), whereas TTE underestimated these parameters compared with CMR (LAmax: 60 vs. 73 mL/m(2), P < 0.0001; LAmin: 50 vs. 64 mL/m(2), P < 0.0001), and also compared with MDCT (LAmax: 60 vs. 80 mL/m(2), P < 0.0001; LAmin: 50 vs. 69 mL/m(2), P < 0.0001). Measurements of LA volumes by MDCT and CMR closely correlated, and both MDCT and CMR had excellent intra- and inter-observer agreement with correlation coefficients of 0.90. The correlation between TTE-derived measurements and CMR/MDCT was fair to moderate. Intra- and inter-observer agreement for LA volume measurements by TTE were inferior to CMR and MDCT. Measurements of LA volumes by CMR and 320-slice MDCT correlate closely in patients with permanent AF, and both modalities improve the reproducibility of measurements of LA volumes and function compared with 2D TTE.
引用
收藏
页码:532 / 540
页数:9
相关论文
共 50 条
  • [1] Left Atrial Passive Emptying Function Is Preserved in Patients with Permanent Atrial Fibrillation - A 320-Slice Multidetector Computed Tomography Study
    Agner, Bue Fridolin Ross
    Kuhl, Jorgen Tobias
    Kofoed, Klaus Fuglsang
    Engstrom, Thomas
    Jensen, Gorm Boje
    Dixen, Ulrik
    CARDIOLOGY, 2014, 129 (03) : 144 - 152
  • [2] Assessment of left atrial volume and function: a comparative study between echocardiography, magnetic resonance imaging and multi slice computed tomography
    J. Tobias Kühl
    Jacob Lønborg
    Andreas Fuchs
    Mads J. Andersen
    Niels Vejlstrup
    Henning Kelbæk
    Thomas Engstrøm
    Jacob E. Møller
    Klaus F. Kofoed
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1061 - 1071
  • [3] Assessment of left atrial volume and function: a comparative study between echocardiography, magnetic resonance imaging and multi slice computed tomography
    Kuhl, J. Tobias
    Lonborg, Jacob
    Fuchs, Andreas
    Andersen, Mads J.
    Vejlstrup, Niels
    Kelbaek, Henning
    Engstrom, Thomas
    Moller, Jacob E.
    Kofoed, Klaus F.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05): : 1061 - 1071
  • [4] A simplified method to determine left atrial volume and transport function using multi-slice computed tomography in patients with atrial fibrillation: comparison with transthoracic echocardiography
    Shin, Seung Yong
    Yong, Hwan Seok
    Na, Jin Oh
    Choi, Cheol Ung
    Kim, Seong Hwan
    Kim, Jin Won
    Kim, Eung Ju
    Rha, Seung-Woon
    Park, Chang Gyu
    Seo, Hong Seog
    Oh, Dong Joo
    Kim, Young-Hoon
    Lim, Hong Euy
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05): : 1205 - 1216
  • [5] A simplified method to determine left atrial volume and transport function using multi-slice computed tomography in patients with atrial fibrillation: comparison with transthoracic echocardiography
    Seung Yong Shin
    Hwan Seok Yong
    Jin Oh Na
    Cheol Ung Choi
    Seong Hwan Kim
    Jin Won Kim
    Eung Ju Kim
    Seung-Woon Rha
    Chang Gyu Park
    Hong Seog Seo
    Dong Joo Oh
    Young-Hoon Kim
    Hong Euy Lim
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1205 - 1216
  • [6] Visualization of coronary arteries and coronary stents by low dose 320-slice multi-detector computed tomography in a patient with atrial fibrillation
    Gaudio, Carlo
    Evangelista, Antonietta
    Pasceri, Vincenzo
    Pannarale, Giuseppe
    Varrica, Salvatore
    Romitelli, Susanna
    Pelliccia, Francesco
    Pellegrini, Massimo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 151 (01) : E6 - E7
  • [7] Association of left atrial volume and function using multi-detector computed tomography
    Anderson, Hunt
    Marvasty, Idean
    Rinehart, Sarah
    Voros, Szilard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A154 - A154
  • [8] Assessment of right ventricular function with 320-slice volume cardiac CT: comparison with cardiac magnetic resonance imaging
    Huang, Xiaoyong
    Pu, Xin
    Dou, Ruiyu
    Guo, Xi
    Yan, Zixu
    Zhang, Zhaoqi
    Li, Meng
    Jiang, Hong
    Lu, Biao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 : 87 - 92
  • [9] Assessment of right ventricular function with 320-slice volume cardiac CT: comparison with cardiac magnetic resonance imaging
    Xiaoyong Huang
    Xin Pu
    Ruiyu Dou
    Xi Guo
    Zixu Yan
    Zhaoqi Zhang
    Meng Li
    Hong Jiang
    Biao Lu
    The International Journal of Cardiovascular Imaging, 2012, 28 : 87 - 92
  • [10] A jumping left atrial thrombus connected to a pulmonary vein thrombus using transthoracic echocardiography and 64-slice multi-detector computed tomography
    Takeuchi, Hidekazu
    IJC HEART & VASCULATURE, 2015, 6 : 32 - 34