Analysis of the ear pulse oximeter waveform

被引:37
|
作者
Awad A.A. [1 ]
Stout R.G. [1 ]
Ghobashy M.A.M. [1 ]
Rezkanna H.A. [2 ]
Silverman D.G. [1 ]
Shelley K.H. [1 ]
机构
[1] Department of Anesthesia, Yale University School of Medicine, New Haven, CT 06516-8051
[2] Department of Anesthesia, Benha Faculty of Medicine, Zagazig University, Zagazig
关键词
Cardiac output; Ear pulse oximeter; Peripheral waveforms;
D O I
10.1007/s10877-006-9018-z
中图分类号
学科分类号
摘要
Objective: For years researchers have been attempting to understand the relationship between central hemodynamics and the resulting peripheral waveforms. This study is designed to further understanding of the relationship between ear pulse oximeter waveforms, finger pulse oximeter waveforms and cardiac output (CO). It is hoped that with appropriate analysis of the peripheral waveforms, clues can be gained to help to optimize cardiac performance. Methods. Part 1: Studying the effect of cold immersion test on plethysmographic waveforms. Part 2: Studying the correlation between ear and finger plethysmographic waveforms and (CO) during CABG surgery. The ear and finger plethysmographic waveforms were analyzed to determine amplitude, width, area, upstroke and downslope. The CO was measured using continuous PA catheter. Using multi-linear regr ession, ear plethysmographic waveforms, together with heart rate (HR), were used to determine the CO Agreement between the two methods of CO determination was assessed. Results. Part 1: On contralateral hand immersion, all finger plethysmographic waveforms were reduced, there was no significant change seen in ear plethysmographic waveforms, except an increase in ear plethysmographic width. Part 2: Phase1: Significant correlation detected between the ear plethysmographic width and other ear and finger plethysmographic waveforms. Phase 2: The ear plethysmographic width had a significant correlation with the HR and CO. The correlation of the other ear plethysmographic waveforms with CO and HR are summarized (Table 5). Multi-linear regression analysis was done and the best fit equation was found to be: CO = 8.084 - 14.248 × Ear width + 0.03 × HR + 92.322 × Ear down slope+0.027 × Ear Area Using Bland & Altman, the bias was (0.05 L) but the precision (2.46) is large to be clinically accepted. Conclusion. The ear is relatively immune to vasoconstrictive challenges which make ear plethysmographic waveforms a suitable monitor for central hemodynamic changes. The ear plethysmographic width has a good correlation with CO. © Springer Science+Business Media, Inc. 2006.
引用
收藏
页码:175 / 184
页数:9
相关论文
共 50 条
  • [21] Pulse oximeter plethysmograph variation and its relationship to the arterial waveform in mechanically ventilated children
    J. R. Chandler
    E. Cooke
    C. Petersen
    W. Karlen
    N. Froese
    J. Lim
    J. M. Ansermino
    Journal of Clinical Monitoring and Computing, 2012, 26 : 145 - 151
  • [22] Pulse oximeter plethysmograph variation and its relationship to the arterial waveform in mechanically ventilated children
    Chandler, J. R.
    Cooke, E.
    Petersen, C.
    Karlen, W.
    Froese, N.
    Lim, J.
    Ansermino, J. M.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (03) : 145 - 151
  • [23] Plethysmographic pulse oximeter waveform variation as an indicator of successful epidural blockade: A prospective study
    Sinha, PK
    Dubey, PK
    Gaur, A
    Singh, PK
    Singh, S
    ANESTHESIOLOGY, 1999, 91 (03) : 899 - 901
  • [24] AC TYPE EAR OXIMETER
    ASADA, T
    SUGIHARA, K
    TAKEDA, Y
    NAKATSUKA, T
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1961, 38 (05): : 224 - &
  • [25] Evaluation of a Novel Ear Pulse Oximeter: Towards Automated Oxygen Titration in Eyeglass Frames
    Braun, Fabian
    Verjus, Christophe
    Sola, Josep
    Marienfeld, Marcus
    Funke-Chambour, Manuela
    Krauss, Jens
    Geiser, Thomas
    Guler, Sabina A.
    SENSORS, 2020, 20 (11) : 1 - 11
  • [26] Development of a miniaturized in-ear pulse oximeter for long term monitoring of risk patients
    Huelsbusch, M.
    Blazek, V.
    Herzog, M.
    Vogel, St.
    Wartzek, T.
    Starke, D.
    Hennig, Th
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 779 - 781
  • [27] A Power Consumption Optimized Reflective In-ear Pulse Oximeter for Mobile Health Monitoring
    Venema, Boudewijn
    Wolke, Matthias Simon
    Blazek, Vladimir
    Leonhardt, Steffen
    2014 IEEE TOPICAL CONFERENCE ON BIOMEDICAL WIRELESS TECHNOLOGIES, NETWORKS, AND SENSING SYSTEMS (BIOWIRELESS), 2014, : 34 - 36
  • [28] Different responses of ear and finger pulse oximeter wave form to cold presser test
    Awad, AA
    Ghobashy, MAM
    Ouda, W
    Stout, RG
    Silverman, DG
    Shelley, KH
    ANESTHESIA AND ANALGESIA, 2001, 92 (06): : 1483 - 1486
  • [29] Pulse oximeter for homecare
    Lopera, JM
    Díaz, J
    Prieto, MJ
    Nuño, F
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1738 - 1739
  • [30] New algorithm for automatic estimation of the respiratory variations in the pulse oximeter waveform in spontaneously breathing patients
    Cannesson, Maxime
    Keller, Geoffray
    Cassar, Emmanuel
    Robert, Jean Michel
    Leber, Jean-Jacques
    CRITICAL CARE MEDICINE, 2007, 35 (12) : A87 - A87