Analysis of the ear pulse oximeter waveform

被引:37
|
作者
Awad A.A. [1 ]
Stout R.G. [1 ]
Ghobashy M.A.M. [1 ]
Rezkanna H.A. [2 ]
Silverman D.G. [1 ]
Shelley K.H. [1 ]
机构
[1] Department of Anesthesia, Yale University School of Medicine, New Haven, CT 06516-8051
[2] Department of Anesthesia, Benha Faculty of Medicine, Zagazig University, Zagazig
关键词
Cardiac output; Ear pulse oximeter; Peripheral waveforms;
D O I
10.1007/s10877-006-9018-z
中图分类号
学科分类号
摘要
Objective: For years researchers have been attempting to understand the relationship between central hemodynamics and the resulting peripheral waveforms. This study is designed to further understanding of the relationship between ear pulse oximeter waveforms, finger pulse oximeter waveforms and cardiac output (CO). It is hoped that with appropriate analysis of the peripheral waveforms, clues can be gained to help to optimize cardiac performance. Methods. Part 1: Studying the effect of cold immersion test on plethysmographic waveforms. Part 2: Studying the correlation between ear and finger plethysmographic waveforms and (CO) during CABG surgery. The ear and finger plethysmographic waveforms were analyzed to determine amplitude, width, area, upstroke and downslope. The CO was measured using continuous PA catheter. Using multi-linear regr ession, ear plethysmographic waveforms, together with heart rate (HR), were used to determine the CO Agreement between the two methods of CO determination was assessed. Results. Part 1: On contralateral hand immersion, all finger plethysmographic waveforms were reduced, there was no significant change seen in ear plethysmographic waveforms, except an increase in ear plethysmographic width. Part 2: Phase1: Significant correlation detected between the ear plethysmographic width and other ear and finger plethysmographic waveforms. Phase 2: The ear plethysmographic width had a significant correlation with the HR and CO. The correlation of the other ear plethysmographic waveforms with CO and HR are summarized (Table 5). Multi-linear regression analysis was done and the best fit equation was found to be: CO = 8.084 - 14.248 × Ear width + 0.03 × HR + 92.322 × Ear down slope+0.027 × Ear Area Using Bland & Altman, the bias was (0.05 L) but the precision (2.46) is large to be clinically accepted. Conclusion. The ear is relatively immune to vasoconstrictive challenges which make ear plethysmographic waveforms a suitable monitor for central hemodynamic changes. The ear plethysmographic width has a good correlation with CO. © Springer Science+Business Media, Inc. 2006.
引用
收藏
页码:175 / 184
页数:9
相关论文
共 50 条
  • [1] Pulse oximeter waveform analysis as a measure of circulatory status
    PM Middleton
    A Retter
    JA Henry
    Critical Care, 5 (Suppl 1):
  • [2] Pulse oximeter ear probe
    Avidan, A
    ANAESTHESIA, 2003, 58 (07) : 726 - 726
  • [3] Different response of ear and finger photoelectric plethysmography (Pulse oximeter waveform) to vasoconstrictive stimuli
    Awad, A
    Ouda, W
    Stout, R
    Silverman, D
    Shelley, KH
    ANESTHESIOLOGY, 2000, 93 (3A) : U166 - U166
  • [4] Wavelet analysis of pulse oximeter waveform permits identification of unwell children
    Leonard, P
    Beattie, TF
    Addison, PS
    Watson, JN
    EMERGENCY MEDICINE JOURNAL, 2004, 21 (01) : 59 - 60
  • [5] Full Finger Reperfusion Time Measured by Pulse Oximeter Waveform Analysis in Children
    Nickel, Amanda J.
    Jiang, Shen
    Napolitano, Natalie
    Yehya, Nadir
    Fitzgerald, Julie C.
    Bruins, Benjamin B.
    Lockman, Justin L.
    Nadkarni, Vinay M.
    Nishisaki, Akira
    CRITICAL CARE MEDICINE, 2020, 48 (10) : E927 - E933
  • [6] The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform
    Shelley K.H.
    Awad A.A.
    Stout R.G.
    Silverman D.G.
    J. Clin. Monit. Comput., 2006, 2 (81-87): : 81 - 87
  • [7] An algorithm for the detection of individual breaths from the pulse oximeter waveform
    Leonard P.
    Grubb N.R.
    Addison P.S.
    Clifton D.
    Watson J.N.
    Journal of Clinical Monitoring and Computing, 2004, 18 (5-6) : 309 - 312
  • [8] The ear as an alternative site for a pulse oximeter finger clip sensor
    Haynes, Jeffrey M.
    RESPIRATORY CARE, 2007, 52 (06) : 727 - 729
  • [9] RESPIRATORY VARIATIONS IN THE PULSE OXIMETER WAVEFORM AMPLITUDE AS INDICATOR OF FLUID RESPONSIVENESS
    Robin, E.
    Derichard, A.
    Fleyfel, M.
    Costecalde, M.
    Lebuffe, G.
    Vallet, B.
    INTENSIVE CARE MEDICINE, 2009, 35 : 134 - 134
  • [10] What is the best site for measuring the effect of ventilation on the pulse oximeter waveform?
    Shelley, Kirk H.
    Jablonka, Denis H.
    Awad, Aymen A.
    Stout, Robert G.
    Rezkanna, Hoda
    Silverman, David G.
    ANESTHESIA AND ANALGESIA, 2006, 103 (02): : 372 - 377