Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method

被引:0
|
作者
E. A. López-Beltrán
P. L. Blackshear
S. M. Finkelstein
J. N. Cohn
机构
[1] University of Minnesota,Biomedical Engineering Program
[2] Univ. Alcalá de Henares,Departamento Electrónica
[3] University of Minnesota,Department of Mechanical Engineering & Biomedical Engineering Program
[4] University of Minnesota,Department of Laboratory Medicine & Pathology & Biomedical Engineering Program
[5] University of Minnesota,Department of Medicine, Cardiovascular Division
关键词
Non-invasive compliance; Photoplethysmography; Pressure-dependent compliance; Peripheral compliance; Age-effect; Repeatability;
D O I
暂无
中图分类号
学科分类号
摘要
A non-invasive technique is implemented to measure a peripheral vascular compliance index Cindex, using an infrared photoplethysmographic waveform as an indicator of intravascular volume change and a continuous blood pressure monitor to measure the blood pressure during each heart-beat. The non-linear behaviour of Cindex with pressure and the effect of age on Cindex are studied in 62 males (15–73 years). Repeatability tests and the effect of ice-water exposure of a portion of a limb are studied in 10 and 14 subjects, respectively. For each individual, Cindex measurements are taken at discrete values of local mean arterial pressure (Pmean), and a Cindex against Pmean plot is obtained. There is a statistically significant difference (p<0.05) in Cindex for the lower values of Pmean (60–100 mmHg) between two age groups formed (15–52 and 58–73 years). The cold-pressor test (CPT) shows a 68% median decrease in Cindex, with an inter-quartile range of 60–77%, in a matter of seconds. The results suggest that Cindex may be a useful noninvasive indicator of peripheral vascular compliance in humans.
引用
收藏
页码:748 / 753
页数:5
相关论文
共 50 条
  • [31] THE ROLE OF NON-INVASIVE VASCULAR STUDIES IN DETERMINING LEVELS OF AMPUTATION
    OISHI, CS
    FRONEK, A
    GOLBRANSON, FL
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (10): : 1520 - 1530
  • [33] A non-invasive pulse pressure method for the estimation of total arterial compliance
    Segers, P
    Stergiopulos, N
    Verdonck, P
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 171 - 174
  • [34] The pulse pressure method for non-invasive evaluation of total arterial compliance
    Carlier, S
    Segers, P
    De Backer, T
    Stergiopoulos, N
    Thomas, J
    JOURNAL OF HYPERTENSION, 2000, 18 : S197 - S197
  • [35] Non-invasive profiling of total peripheral vascular resistance using the Dundee step test.
    Lim, PO
    MacDonald, TM
    AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 173A - 173A
  • [36] TrackballWatch: Trackball and Rotary Knob as a Non-Occluding Input Method for Smartwatches in Map Navigation Scenarios
    Stanke D.
    Schroth P.
    Rohs M.
    Proceedings of the ACM on Human-Computer Interaction, 2022, 6 (MHCI):
  • [37] Investigations of the peripheral vascular mechanisms implicated in congestive heart failure by the non-invasive evaluation of radial artery compliance and reactivity
    Khder, Y
    ElGhawi, R
    Boscs, LBD
    Aliot, E
    Zannad, F
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1996, 56 (02) : 149 - 158
  • [38] TREATMENT COMPLIANCE IN HOME NON-INVASIVE VENTILATION
    Cheng, S-L
    Chan, V.
    Chu, C-M
    RESPIROLOGY, 2011, 16 : 232 - 232
  • [39] On Non-Invasive Measurement of Gastric Motility from Finger Photoplethysmographic Signal
    Yacin, S. Mohamed
    Manivannan, M.
    Chakravarthy, V. Srinivasa
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (12) : 3744 - 3755
  • [40] NON-INVASIVE MEASUREMENT OF STATIC LUNG COMPLIANCE
    TOBIN, MJ
    JENOURI, G
    WATSON, H
    SACKNER, MA
    FEDERATION PROCEEDINGS, 1982, 41 (05) : 1625 - 1625