Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method

被引:0
|
作者
E. A. López-Beltrán
P. L. Blackshear
S. M. Finkelstein
J. N. Cohn
机构
[1] University of Minnesota,Biomedical Engineering Program
[2] Univ. Alcalá de Henares,Departamento Electrónica
[3] University of Minnesota,Department of Mechanical Engineering & Biomedical Engineering Program
[4] University of Minnesota,Department of Laboratory Medicine & Pathology & Biomedical Engineering Program
[5] University of Minnesota,Department of Medicine, Cardiovascular Division
关键词
Non-invasive compliance; Photoplethysmography; Pressure-dependent compliance; Peripheral compliance; Age-effect; Repeatability;
D O I
暂无
中图分类号
学科分类号
摘要
A non-invasive technique is implemented to measure a peripheral vascular compliance index Cindex, using an infrared photoplethysmographic waveform as an indicator of intravascular volume change and a continuous blood pressure monitor to measure the blood pressure during each heart-beat. The non-linear behaviour of Cindex with pressure and the effect of age on Cindex are studied in 62 males (15–73 years). Repeatability tests and the effect of ice-water exposure of a portion of a limb are studied in 10 and 14 subjects, respectively. For each individual, Cindex measurements are taken at discrete values of local mean arterial pressure (Pmean), and a Cindex against Pmean plot is obtained. There is a statistically significant difference (p<0.05) in Cindex for the lower values of Pmean (60–100 mmHg) between two age groups formed (15–52 and 58–73 years). The cold-pressor test (CPT) shows a 68% median decrease in Cindex, with an inter-quartile range of 60–77%, in a matter of seconds. The results suggest that Cindex may be a useful noninvasive indicator of peripheral vascular compliance in humans.
引用
收藏
页码:748 / 753
页数:5
相关论文
共 50 条
  • [1] Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method
    López-Beltrán, EA
    Blackshear, PL
    Finkelstein, SM
    Cohn, JN
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (06) : 748 - 753
  • [2] Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method
    López-Beltrán, E.A.
    Blackshear, P.L.
    Finkelstein, S.M.
    Cohn, J.N.
    Medical and Biological Engineering and Computing, 1998, 36 (06): : 748 - 753
  • [3] NON-INVASIVE ESTIMATION OF CEREBRAL VASCULAR COMPLIANCE
    Kim, Mi-Ok
    Avolio, Alberto
    HYPERTENSION, 2011, 58 (01) : 126 - 126
  • [4] Non-invasive Haemoglobin Measurement Using Photoplethysmographic Technique
    Nidhyananthan, S. Selva
    Shahini, R. Dharshana
    Priya, S. Hari
    INTELLIGENT COMMUNICATION TECHNOLOGIES AND VIRTUAL MOBILE NETWORKS, ICICV 2019, 2020, 33 : 311 - 316
  • [5] Non-invasive vascular imaging of peripheral vessels
    Reimer, P
    Landwehr, P
    EUROPEAN RADIOLOGY, 1998, 8 (06) : 858 - 872
  • [6] Non-invasive vascular imaging of peripheral vessels
    P. Reimer
    P. Landwehr
    European Radiology, 1998, 8 : 858 - 872
  • [7] Method of non-invasive assessment of myocardial compliance
    Hu, W. C.
    Liu, C. P.
    Hus, T. J.
    Shyu, L. Y.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3419 - +
  • [8] NON-INVASIVE EVALUATION OF PERIPHERAL VASCULAR-DISEASE
    RAINES, J
    TRAAD, E
    MEDICAL CLINICS OF NORTH AMERICA, 1980, 64 (02) : 283 - 304
  • [9] TECHNOLOGY FOR NON-INVASIVE DIAGNOSIS OF PERIPHERAL VASCULAR FLOW
    HAYES, JP
    EVANS, WE
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (08) : 597 - 597
  • [10] NON-INVASIVE VASCULAR STUDIES IN RATTLESNAKE ENVENOMATION
    KRANER, J
    KUNKEL, D
    RYAN, P
    VANCE, M
    VETERINARY AND HUMAN TOXICOLOGY, 1983, 25 (04) : 284 - 284