A simple method for multi-element analysis of geological samples has been developed. In this work, compromise conditions involving optimizing the operating parameters of the ICP, adjustment of ion optics voltages and selection of internal standards were carefully investigated. Matrix trace element-matching procedures were employed, in which the external calibration solutions were prepared by dividing the elements of interest into seven groups of different concentration levels according to their average contents of 20 typical standard reference rock samples. The proposed method offered simple procedure of sample preparation, instrument calibration, improved precision and reasonable element coverage. Detection limits ranged from 0.003–0.1 µg g-1 for heavier mass elements to 0.01–1 µg g-1 for lighter mass elements. Precision was near 1.1–10% RSD (lighter mass elements) and 2.0–8.0% RSD (heavier mass elements), respectively, with the exceptions of tungsten, molybdenum and thorium. Good agreement between certified and found values were achieved for standard reference rock samples AGV-1, BHVO-2 and GSR-3. Analytical data for rare earth elements were in conformity with values from the chondrite normalized curve.
引用
收藏
页码:1291 / 1296
页数:5
相关论文
共 50 条
  • [31] Determination of trace elements in zeolites by laser ablation ICP-MS
    Pickhardt, C
    Brenner, IB
    Becker, JS
    Dietze, HJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (01): : 79 - 87
  • [32] ICP-MS determination of trace elements in serum samples of healthy subjects using different sample preparation methods
    Dombovári, J
    Varga, Z
    Becker, JS
    Mátyus, J
    Kakuk, G
    Papp, L
    ATOMIC SPECTROSCOPY, 2001, 22 (04) : 331 - 335
  • [34] Determination of trace elements in siliceous samples by ICP-MS after precipitation of silicon as sodium fluorosilicate
    Arslan, Zikri
    Tyson, Julian F.
    MICROCHIMICA ACTA, 2008, 160 (1-2) : 219 - 225
  • [35] Comparison of ICP-MS and ICP-OES in the Determination of Trace Elements in Water
    Cidu, R.
    Atomic Spectroscopy, 17 (04):
  • [36] Determination of trace elements in siliceous samples by ICP-MS after precipitation of silicon as sodium fluorosilicate
    Zikri Arslan
    Julian F. Tyson
    Microchimica Acta, 2008, 160 : 219 - 225
  • [37] Use of Xenon as Internal Standard for the Accurate Determination of Trace Elements in Water Samples by ICP-MS
    Balaram, V.
    Satyanarananan, M.
    Avdeev, D. V.
    Berdnikov, N.
    Roy, Parijat
    Sawant, S. S.
    Subramanyam, K. S. V.
    Anjaiah, K. V.
    Kamala, C. T.
    Mathur, Ramavathi
    Dasaram, B.
    ATOMIC SPECTROSCOPY, 2012, 33 (02) : 41 - 47
  • [38] Determination of trace tantalum in geological samples by ICP-MS after extraction by graphene oxide / chitosan beads
    Faculty of Materials Science and Chemistry, China University of Geosciences , Wuhan
    430074, China
    不详
    563000, China
    不详
    430034, China
    Chin. J. Anal. Lab., 2022, 1 (29-32): : 29 - 32
  • [40] Detection of Trace Elements in the Sediment of Lop Nur Samples by ICP-MS
    Hu Xin
    An Deng-di
    Dlinur, Mlik
    Li Jiang
    Liu Yu-xiang
    Ji Heng-ying
    Zhu Yan-lei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (06) : 1674 - 1676