Assessment of stereotactic high-resolution detectors for stereotactic body radiotherapy: comparative analysis between myQA® SRS and Gafchromic EBT-XD films

被引:1
|
作者
Chinnaiya, Dinesan [1 ,2 ]
Mudhana, Gopinath [1 ]
机构
[1] Vellore Inst Technol, Sch Adv Sci, Dept Phys, Chennai 600127, India
[2] Sri Shankara Canc Hosp & Res Ctr, Dept Radiat Oncol, Bangalore, India
关键词
SBRT patient-specific QA; myQA SRS detector; Gafchromic EBT-XD film; DOSIMETRY; PROTOCOL;
D O I
10.1007/s00411-024-01071-6
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The study aimed to evaluate dosimetry systems used for stereotactic body radiotherapy (SBRT), specifically 2D array dosimetry and film dosimetry systems, for exploring their characteristics and clinical suitability. For this, high-resolution myQA SRS detectors and Gafchromic EBT-XD films were employed. Film analysis included net optical density (OD) values depending on energy, dose rate, scanner orientation, scanning side, and post-exposure growth. For myQA SRS, signal values were evaluated in terms of dose rate (400-1400 MU/min) and angular dependence (0-180 degrees at 30 degrees intervals) along with couch angles of 0 degrees, 45 degrees, and 90 degrees. Pre-treatment verification included 32 SBRT patients for whom myQA SRS results were compared with those obtained with Gafchromic EBT-XD films. Analysis revealed less than 1% deviation in net OD for energy and dose rate dependence. Scanner orientation caused 2.5% net OD variation, with minimal differences between film front and back scan orientations (variance < 1.0%). A rapid OD rise occurred within six hours post-exposure, followed by gradual increase. The myQA SRS detector showed - 3.7% dose rate dependence (400 MU/min), while the angular dependence at 90 degrees was - 26.7%. A correction factor effectively reduced these differences to < 1%. For myQA SRS, gamma passing rates were-93.6% (2%/1 mm), while those for EBT-XD films were-92.8%. Improved rates were observed with 3%/1 mm: for myQA SRS-97.9%, and for EBT-XD film-98.16%. In contrast, for 2%/2 mm with 10% threshold, for myQA SRS-97.7% and for EBT-XD film-98.97% were obtained. It is concluded that both myQA SRS detectors and EBT-XD films are suitable for SBRT pre-treatment verification, ensuring accuracy and reliability. However, myQA SRS detectors are preferred over EBT-XD film due to the fact that they offer real-time measurements and user-friendly features.
引用
收藏
页码:203 / 214
页数:12
相关论文
共 11 条
  • [1] Clinical Comparison of Gafchromic EBT-XD Film to Gafchromic EBT3 Film When Utilized as An Absolute Dose Verification Method in Stereotactic Radiotherapy
    Goodman, R.
    Murphy, T.
    Siergiej, D.
    Schroeder, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E280 - E280
  • [2] Gafchromic EBT-XD Film for Dose Profile Evaluation and Absolute Dose Measurement in High Dose Stereotactic Treatments
    Joseph, R.
    Hatzinikolaou, G.
    Kriminski, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E645 - E646
  • [3] A comparison between Gafchromic EBT3 and EBT-XD films for pre-treatment QA of SBRT/SRS plans
    Santos, T.
    Ventura, T.
    Capela, M.
    Mateus, J.
    Lopes, M. D. C.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1343 - S1344
  • [4] Effect of glass compression plate on EBT-XD film dosimetry for pretreatment quality assurance of stereotactic body radiotherapy
    Raj, Sathiya
    Shree, Nithya
    Ganesh, K. M.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2024, 29 (03) : 357 - 361
  • [5] Absolute Film Dosimetry for Stereotactic Radiosurgery and Stereotactic Body Radiotherapy Quality Assurance Using Gafchromic EBT3 Films
    Wen, N.
    Lu, S.
    Qin, Y.
    Huang, Y.
    Zhao, B.
    Liu, C.
    Chetty, I.
    MEDICAL PHYSICS, 2016, 43 (06) : 3593 - 3593
  • [6] Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films
    Wen, Ning
    Lu, Siming
    Kim, Jinkoo
    Qin, Yujiao
    Huang, Yimei
    Zhao, Bo
    Liu, Chang
    Chetty, Indrin J.
    RADIATION ONCOLOGY, 2016, 11
  • [7] Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films
    Ning Wen
    Siming Lu
    Jinkoo Kim
    Yujiao Qin
    Yimei Huang
    Bo Zhao
    Chang Liu
    Indrin J. Chetty
    Radiation Oncology, 11
  • [8] A comparative dosimetric analysis of virtual stereotactic body radiotherapy to high-dose-rate monotherapy for intermediate-risk prostate cancer
    Spratt, Daniel E.
    Scala, Lawrence M.
    Folkert, Michael
    Voros, Laszlo
    Cohen, Gil'ad N.
    Happersett, Laura
    Katsoulakis, Evangelia
    Zelefsky, Michael J.
    Kollmeier, Marisa A.
    Yamada, Yoshiya
    BRACHYTHERAPY, 2013, 12 (05) : 428 - 433
  • [9] A Comparative Analysis between 3D Non-coplanar Beam Technique (NCBT) vs. Single-isocenter Multi-segment Conformal Arc (SiMs) Technique for Liver Stereotactic Body Radiotherapy (SBRT)
    Chang, B. W.
    Ross, C.
    Ediriwickrema, L. S.
    Decker, R. H.
    Kim, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S314 - S314
  • [10] Comparison of long-term survival outcomes between stereotactic body radiotherapy and sublobar resection for stage I non-small-cell lung cancer in patients at high risk for lobectomy: A propensity score matching analysis
    Matsuo, Yukinori
    Chen, Fengshi
    Hamaji, Masatsugu
    Kawaguchi, Atsushi
    Ueki, Nami
    Nagata, Yasushi
    Sonobe, Makoto
    Morita, Satoshi
    Date, Hiroshi
    Hiraoka, Masahiro
    EUROPEAN JOURNAL OF CANCER, 2014, 50 (17) : 2932 - 2938