Analysis of Enlarged Images Using Time-of-Flight Magnetic Resonance Angiography, Computed Tomography, and Conventional Angiography

被引:0
|
作者
Yeong-Cheol Heo
Hae-Kag Lee
Han-Jun Yang
Jae-Hwan Cho
机构
[1] Kyung Hee University Hospital at Gang-dong,Department of Radiology
[2] Hallym University of Graduate Studies,Department of International Radiological Science
[3] Soonchunhyang University,Department of Computer Engineering
来源
关键词
Magnetic resonance angiography; Computed tomography angiography; Flow phantom; Vascular diameter;
D O I
暂无
中图分类号
学科分类号
摘要
This study aimed to assess the accuracy of time-of-flight magnetic resonance angiography, computed tomography, and conventional angiography in depicting the actual length of the blood vessels. Three-dimensional time-of-flight magnetic resonance angiography and computed tomography angiography were performed using a flow phantom model that was 2.11 mm in diameter and had a total area of 0.26 cm2. After this, volume rendering technique and the maximum intensity projection method as well as two-dimensional digital subtraction angiography and three-dimensional rotational angiography based on conventional angiography were conducted. For three-dimensional time-of-flight magnetic resonance angiography, 8 channel sensitivity encoding (SENSE) head coil for the 3.0 Tesla equipment was used. Fluid was added to the normal saline solution at various rates, such as 11.4, 20.0, 31.4, 40.0, 51.5, 60.0, 71.5, 80.1, 91.5, and 100.1 cm/s using an automatic contrast media injector. Each image was thoroughly examined. After reconstructing the image using the maximum intensity projection method, the length of the conduit in the center of the coronal plane was measured 30 times. After performing computed tomography angiography with the 64-channel CT scanner and 16-channel CT scanner, the images were sent to TeraRecon. Then, the length of the conduit in the center of the coronal plane of each image was measured 30 times after reconstructing the images using volume rendering and maximum intensity projection techniques. For conventional angiography, three-dimensional rotational angiography and two-dimensional digital subtraction angiography were used. Images obtained by three-dimensional rotational angiography were reconstructed and enhanced by 33, 50, and 100 % in the 128 Matrix and the 256 Matrix, respectively on the Xtra Vision workstation. The maximum intensity projection was used for the reconstruction, and the length of the conduit was measured 30 times in the center of the coronal plane of each image. Measurements using the two-dimensional digital subtraction angiography were obtained 30 times in the center of the image. As a result, the lumen length measured by three-dimensional enhanced flow MR angiography images was a minimum of 2.51 ± 0.12 mm when the fluid velocity was 40 cm/s. The images obtained by computed tomography angiography were larger than the actual images obtained by using the test equipment and the reconstruction method. Among the reconstruction methods of three-dimensional rotational angiography, the lumen length in the image reconstructed by 100 % in the 256 matrix was the smallest; 2.76 ± 0.009 mm. In the 128 matrix, as the scope of reconstruction was widened, the length of the vessel was increased by 0.710 units. In the 256 matrix, as the scope of reconstruction was widened, the length of the vessel was decreased by 0.972 units. In two-dimensional digital subtraction angiography, the lumen length in the image was 2.22 ± 0.095 mm. Although this image was magnified similar to the image reconstructed by 100 % in the 256 matrix of three-dimensional rotational angiography (P < 0.05), it was closest to the actual image among the images compared in this study. In conclusion, images obtained by two-dimensional digital subtraction angiography were closer to the actual images compared to the images obtained by other procedures. It can be concluded that vascular images obtained by magnetic resonance angiography, CT angiography, and conventional angiography were larger than the actual images.
引用
收藏
相关论文
共 50 条
  • [1] Analysis of Enlarged Images Using Time-of-Flight Magnetic Resonance Angiography, Computed Tomography, and Conventional Angiography
    Heo, Yeong-Cheol
    Lee, Hae-Kag
    Yang, Han-Jun
    Cho, Jae-Hwan
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2014, 38 (12)
  • [2] Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography
    Kim, Eng-Chan
    Heo, Yeong-Cheol
    Cho, Jae-Hwan
    Lee, Hyun-Jeong
    Lee, Hae-Kag
    [J]. JOURNAL OF MAGNETICS, 2014, 19 (02) : 185 - 191
  • [3] 3 T contrast-enhanced magnetic resonance angiography for evaluation of the intracranial arteries - Comparison with time-of-flight magnetic resonance angiography and multislice computed tomography angiography
    Villablanca, J. Pablo
    Nael, Kambiz
    Habibi, Reza
    Nael, Ali
    Laub, Gerhard
    Finn, J. Paul
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (11) : 799 - 805
  • [4] Time-of-flight magnetic resonance angiography at 7 tesla
    Heverhagen, Johannes T.
    Bourekas, Eric
    Sammet, Steffen
    Knopp, Michael V.
    Schmalbrock, Petra
    [J]. INVESTIGATIVE RADIOLOGY, 2008, 43 (08) : 568 - 573
  • [5] Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model
    Heo, Yeong-Cheol
    Lee, Hae-Kag
    Park, Cheol-Soo
    Cho, Jae-Hwan
    [J]. JOURNAL OF MAGNETICS, 2015, 20 (01) : 40 - 46
  • [6] Visualization of venous systems by time-of-flight magnetic resonance angiography
    Ko, Sang B.
    Kim, Dong-Eog
    Kim, Se H.
    Roh, Jae-Kyu
    [J]. JOURNAL OF NEUROIMAGING, 2006, 16 (04) : 353 - 356
  • [7] MAGNETIZATION TRANSFER TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY
    PIKE, GB
    HU, BS
    GLOVER, GH
    ENZMANN, DR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 372 - 379
  • [8] Vasa previa evaluated by noncontrast time-of-flight magnetic resonance angiography
    Lwahashi, Naoyuki
    Ota, Nami
    Shiro, Michihisa
    Yagi, Shigetaka
    Minami, Sawako
    Ina, Kazuhiko
    [J]. TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2016, 55 (04): : 585 - 587
  • [9] Quantitative Time-of-Flight Head Magnetic Resonance Angiography of Cerebrovascular Disease
    Koktzoglou, Ioannis
    Ozturk, Onural
    Walker, Matthew T.
    Ankenbrandt, William J.
    Ong, Archie L.
    Ares, William J.
    Gil, Fulvio R.
    Bulwa, Zachary B.
    Edelman, Robert R.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024,
  • [10] Adaptive segmentation of cerebrovascular tree in time-of-flight magnetic resonance angiography
    J. T. Hao
    M. L. Li
    F. L. Tang
    [J]. Medical & Biological Engineering & Computing, 2008, 46 : 75 - 83