3 T contrast-enhanced magnetic resonance angiography for evaluation of the intracranial arteries - Comparison with time-of-flight magnetic resonance angiography and multislice computed tomography angiography

被引:51
|
作者
Villablanca, J. Pablo
Nael, Kambiz
Habibi, Reza
Nael, Ali
Laub, Gerhard
Finn, J. Paul
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[2] Siemens Med Solut, Los Angeles, CA USA
关键词
MR angiography; intracranial arteries; CT angiography; high magnetic field or 3 T; parallel acquisition;
D O I
10.1097/01.rli.0000242835.00032.f5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We sought to prospectively evaluate the image quality and visualization of the intracranial arteries using high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) at 3 T and to perform intraindividual comparison with time-of-flight (TOF) MRA and multislice CT angiography (CTA). Materials and Methods: Twelve patients (5 men, 7 women, 37-71 years of age) with suspected cerebrovascular disease prospectively underwent MRA and CTA. MRA was performed on a 3 T MR system, including both 3-dimensional (3D) TOF (Voxel dimension: 0.6 X 0.5 X 0.9 mm(3) in 5 minutes and 40 seconds) and 3D CE-MRA (voxel dimension: 0.7 X 0.7 X 0.8 mm(3) in 20 seconds, using parallel acquisition with an acceleration factor of 4). CTA images were acquired on a 16-slice CT scanner (voxel dimension: 0.35 X 0.35 X 0.8 mm(3) in 17 seconds). The image quality and visualization of up to 26 intracranial arterial segments in each study was evaluated by 2 experienced radiologists. The arterial diameter for selective intracranial arteries was measured independently on each of the 3 studies, and statistical analysis and comparative correlation was performed. Results: A total of 312 arterial segments were examined by CE-MRA, TOF-MRA, and CTA. The majority of intracranial arteries (87%) were visualized with diagnostic image quality on CE-MRA with a significant correlation to TOF (R values = 0.84; 95% confidence interval 0.79-0.86, P < 0.0001), and to CTA (R values = 0.74; 95% confidence interavl 0.68-0.78, P < 0.001). The image quality for small intracranial arteries, including the anterior-inferior cerebellar artery, the posterior communicating artery, and the M3 branch of the middle cerebral artery, was significantly lower on CE-MRA compared with TOF and CTA (P < 0.03). There was a significant correlation for the dimensional measurements of arterial diameters at CE-MRA with TOF (r = 0.88, 95% confidence interval 0.81-0.93), and CTA (r = 0.83, 95% confidence interval 0.73-0.90). Conclusion: The described 3 T CE-MRA protocol, spanning from the cervical to the intracranial vessels, visualized and characterized the majority of intracranial arteries with image quality comparable with that obtained using TOF-MRA and CTA. Further clinical studies are required to establish the accuracy of the technique in a broader clinical setting.
引用
收藏
页码:799 / 805
页数:7
相关论文
共 50 条
  • [1] Contrast-enhanced Magnetic Resonance Angiography in Stroke Diagnostics Additional Information Compared with Time-of-Flight Magnetic Resonance Angiography?
    Alfke, K.
    Jensen, U.
    Pool, C.
    Rohr, A.
    Bruening, R.
    Weber, J.
    Bartsch, T.
    Stingele, R.
    Jansen, O.
    [J]. CLINICAL NEURORADIOLOGY, 2011, 21 (01) : 5 - 10
  • [2] Contrast-enhanced magnetic resonance angiography carotid arteries
    U-King-Im, J
    Trivedi, R
    Gillard, JH
    [J]. STROKE, 2003, 34 (05) : E15 - E15
  • [3] Contrast-enhanced MR angiography at 3T in the evaluation of intracranial aneurysms: A comparison with time-of-flight MR angiography
    Nael, K.
    Villablanca, J. P.
    Saleh, R.
    Pope, W.
    Nael, A.
    Laub, G.
    Finn, J. P.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (10) : 2118 - 2121
  • [4] Visualisation of lenticulostriate arteries using contrast-enhanced time-of-flight magnetic resonance angiography at 7 Tesla
    Osuafor, Christopher N.
    Rua, Catarina
    Mackinnon, Andrew D.
    Egle, Marco
    Benjamin, Philip
    Tozer, Daniel J.
    Rodgers, Christopher T.
    Markus, Hugh S.
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01):
  • [5] Visualisation of lenticulostriate arteries using contrast-enhanced time-of-flight magnetic resonance angiography at 7 Tesla
    Christopher N. Osuafor
    Catarina Rua
    Andrew D. Mackinnon
    Marco Egle
    Philip Benjamin
    Daniel J. Tozer
    Christopher T. Rodgers
    Hugh S. Markus
    [J]. Scientific Reports, 12 (1)
  • [6] Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries
    Al-Kwifi, O
    Emery, DJ
    Wilman, AH
    [J]. MAGNETIC RESONANCE IMAGING, 2002, 20 (02) : 181 - 187
  • [7] Follow-up of coiled cerebral aneurysms: Comparison of three-dimensional time-of-flight magnetic resonance angiography at 3 tesla with three-dimensional time-of-flight magnetic resonance angiography and contrast-enhanced magnetic resonance angiography at 1.5 tesla
    Anzalone, Nicoletta
    Scomazzoni, Francesco
    Cirillo, Mario
    Cadioli, Marcello
    Iadanza, Antonella
    Kirchin, Miles A.
    Scotti, Giuseppe
    [J]. INVESTIGATIVE RADIOLOGY, 2008, 43 (08) : 559 - 567
  • [8] Contrast-Enhanced Magnetic Resonance Angiography
    Chandra, Tushar
    Pukenas, Bryan
    Mohan, Suyash
    Melhem, Elias
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 687 - +
  • [9] Contrast-Enhanced Magnetic Resonance Angiography
    Vasile, Julie V.
    Newman, Tiffany M.
    Prince, Martin R.
    Rusch, David G.
    Greenspun, David T.
    Allen, Robert J.
    Levine, Joshua L.
    [J]. CLINICS IN PLASTIC SURGERY, 2011, 38 (02) : 263 - +
  • [10] Contrast-enhanced magnetic resonance angiography
    Roditi, G
    [J]. BRITISH JOURNAL OF SURGERY, 2002, 89 (07) : 817 - 820