Monolithic class IV type flextensional transducers

被引:0
|
作者
Anne-Christine Hladky-Hennion
A. Erman Uzgur
Robert E. Newnham
机构
[1] IEMN,Department of Materials Science and Engineering
[2] UMR 8520 CNRS,The Materials Research Laboratory
[3] Ondokuz Mayıs University,undefined
[4] The Pennsylvania State University,undefined
来源
关键词
Underwater transducer; Biomedical transducer; Monolithic; Class IV flextensional; FEA;
D O I
暂无
中图分类号
学科分类号
摘要
In this study new type piezoelectric monolithitic low cost underwater and biomedical transducers based on Class IV flextensional transducer design has been introduced. Transducers were produced by using two techniques: fused deposition and extrusion. Besides, finite element analysis (FEA) was used extensively in order to optimize transducer design to achieve broad bandwidth for both transmitting and receiving and engineered vibration modes. Class IV transducers possess resonance frequencies in the range of above 30 kHz to below 150 kHz. Symmetry and design of the transducer, poling patterns, driving and receiving electrode geometries and driving conditions have strong effect on the vibration modes, resonance frequencies.
引用
收藏
页码:139 / 144
页数:5
相关论文
共 50 条
  • [31] A class V flextensional transducer: the cymbal
    Zhang, JD
    Hughes, WJ
    Bouchilloux, P
    Meyer, RJ
    Uchino, K
    Newnham, RE
    ULTRASONICS, 1999, 37 (06) : 387 - 393
  • [32] Piezoelectrically actuated flextensional micromachined ultrasound transducers -: I:: Theory
    Perçin, G
    Khuri-Yakub, BT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (05) : 573 - 584
  • [33] Comprehensive analysis of Mn:PIN-PMN-PT single crystals for Class IV flextensional transducer
    Guo, Rongjing
    Li, Shiyang
    An, Dawei
    Han, Tao
    Chen, Jing
    Cao, Wenwu
    CERAMICS INTERNATIONAL, 2018, 44 (03) : 2864 - 2868
  • [34] Dual Flat Flextensional Ultrasound Transducers for Enhancement of Transdermal Drug Delivery
    Zhang, Hong-Ye
    Yeo, Swee-Hock
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2004, 43 (9 A): : 6488 - 6493
  • [35] Micromachined piezoelectrically actuated flextensional transducers for high resolution printing and imaging
    Perçin, G
    Khuri-Yakub, BT
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 921 - 924
  • [36] Micromachined 2-D array piezoelectricallly actuated flextensional transducers
    Percin, G
    Khuri-Yakub, BT
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 959 - 962
  • [37] Design optimization of a Class VII Flextensional Transducer
    Moosad, K. P. B.
    Abraham, Pushpa
    APPLIED ACOUSTICS, 2015, 100 : 3 - 9
  • [38] Characterization of novel flextensional transducers designed by using topology optimization method
    Nader, G
    Silva, ECN
    Adamowski, JC
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 981 - 984
  • [39] Experimental verification of flextensional transducers designed by using topology optimization method
    Nader, G
    Silva, ECN
    Adamowski, JC
    SMART STRUCTURES AND MATERIALS 2001: SMART STRUCTURES AND INTEGRATED SYSTEMS, 2001, 4327 : 381 - 389
  • [40] Piezoelectrically actuated flextensional micromachined ultrasound transducers -: II:: Fabrication and experiments
    Perçin, G
    Khuri-Yakub, BT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (05) : 585 - 595