Comparison of internal radiation doses estimated by MIRD and voxel techniques for a "family" of phantoms

被引:0
|
作者
Terry Smith
Nina Petoussi-Henss
Maria Zankl
机构
[1] Department of Radiology,
[2] Great Ormond Street Hospital for Children NHS Trust,undefined
[3] Great Ormond Street,undefined
[4] London WC1N 3JH,undefined
[5] UK,undefined
[6] GSF – National Research Centre for Environment and Health,undefined
[7] Institute of Radiation Protection,undefined
[8] Ingolstädter Landstrasse 1,undefined
[9] 85764 Neuherberg,undefined
[10] Germany,undefined
[11] Correspondence to: 5 Ruckles Way,undefined
[12] Amersham,undefined
[13] Buckinghamshire HP7 0BZ,undefined
[14] UK,undefined
来源
关键词
Voxel phantoms MIRD phantoms Specific absorbed fractions Internal dosimetry Radiopharmaceutical dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to use a new system of realistic voxel phantoms, based on computed tomography scanning of humans, to assess its ability to specify the internal dosimetry of selected human examples in comparison with the well-established MIRD system of mathematical anthropomorphic phantoms. Differences in specific absorbed fractions between the two systems were inferred by using organ dose estimates as the end point for comparison. A "family" of voxel phantoms, comprising an 8-week-old baby, a 7-year-old child and a 38-year-old adult, was used and a close match to these was made by interpolating between organ doses estimated for pairs of the series of six MIRD phantoms. Using both systems, doses were calculated for up to 22 organs for four radiopharmaceuticals with widely differing biodistribution and emission characteristics (technetium-99m pertechnetate, administered without thyroid blocking; iodine-123 iodide; indium-111 antimyosin; oxygen-15 water). Organ dose estimates under the MIRD system were derived using the software MIRDOSE 3, which incorporates specific absorbed fraction (SAF) values for the MIRD phantom series. The voxel system uses software based on the same dose calculation formula in conjunction with SAF values determined by Monte Carlo analysis at the GSF of the three voxel phantoms. Effective doses were also compared. Substantial differences in organ weights were observed between the two systems, 18% differing by more than a factor of 2. Out of a total of 238 organ dose comparisons, 5% differed by more than a factor of 2 between the systems; these included some doses to walls of the GI tract, a significant result in relation to their high tissue weighting factors. Some of the largest differences in dose were associated with organs of lower significance in terms of radiosensitivity (e.g. thymus). In this small series, voxel organ doses tended to exceed MIRD values, on average, and a 10% difference was significant when all 238 organ doses were considered as a single group. In 12 comparisons of effective dose, the mean voxel to MIRD ratio was 1.07 (range 0.72–1.32). It was shown for the majority of cases that, whereas some large differences in SAF values exist, differences in source organ and effective dose values between the MIRD and voxel methods were largely accounted for by the respective organ mass differences. The reasons for various organ dose differences with the selected radiopharmaceuticals are discussed. Taking biological variation into account, there is reasonable agreement between the two methods but some significant differences exist that warrant further investigation. More extensive comparisons involving a wide variety of voxel phantoms are required to establish whether realistic voxel phantoms should eventually replace the MIRD system.
引用
收藏
页码:1387 / 1398
页数:11
相关论文
共 24 条
  • [21] Characterization of 90Y-SPECT/CT self-calibration approaches on the quantification of voxel-level absorbed doses following 90Y-microsphere selective internal radiation therapy
    Balagopal, Anjali
    Kappadath, S. Cheenu
    MEDICAL PHYSICS, 2018, 45 (02) : 875 - 883
  • [22] The effect of anatomical modeling on space radiation dose estimates: a comparison of doses for NASA phantoms and the 5th, 50th, and 95th percentile male and female astronauts
    Bahadori, Amir A.
    Van Baalen, Mary
    Shavers, Mark R.
    Dodge, Charles
    Semones, Edward J.
    Bolch, Wesley E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06): : 1671 - 1694
  • [23] Target Volume Coverage and Organ at Risk Doses for Left-sided Whole-breast Irradiation With or Without Internal Mammary Chain Irradiation: A Comparison Between Three Techniques Representing the Past and the Present
    Bogers, S. L. C.
    Petoukhova, A. L.
    Penninkhof, J. J.
    Mast, M. E.
    Poortmans, P. M.
    Hoogeman, M. S.
    Struikmans, H.
    CLINICAL ONCOLOGY, 2022, 34 (08) : 537 - 544
  • [24] Dosimetric comparison of incidental radiation to the internal mammary nodes after breast-conserving surgery using 3 techniques-inverse intensity-modulated radiotherapy, field-in-field intensity-modulated radiotherapy, and 3-dimensional conformal radiotherapy A retrospective clinical study
    Song, Yuanfang
    Yu, Ting
    Wang, Wei
    Li, Jianbin
    Sun, Tao
    Qiu, Pengfei
    Xu, Min
    Shao, Qian
    MEDICINE, 2019, 98 (41)