UHPLC–MS/MS method for the determination of bisphenol A and its chlorinated derivatives, bisphenol S, parabens, and benzophenones in human urine samples

被引:0
|
作者
F. Vela-Soria
O. Ballesteros
A. Zafra-Gómez
L. Ballesteros
A. Navalón
机构
[1] University of Granada,Research Group of Analytical Chemistry and Life Sciences, Department of Analytical Chemistry
来源
关键词
Endocrine-disrupting chemicals; Human urine analysis; Dispersive liquid–liquid microextraction; Liquid chromatography–tandem mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
In the present work, a new method based on a sample treatment by dispersive liquid–liquid microextraction (DLLME) for the extraction of six bisphenols (bisphenol A, bisphenol S, and monochloro-, dichloro-, trichloro-, and tetrachlorobisphenol A), four parabens (methyl-, ethyl-, propyl-, and butylparaben), and six benzophenones (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-6, benzophenone-8, and 4-hydroxybenzophenone) in human urine samples, followed by ultrahigh-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) analysis, is validated. An enzymatic treatment allows determining the total content of the target EDCs. The extraction parameters were accurately optimized using multivariate optimization strategies. Ethylparaben ring-13C6, benzophenone-d10, and bisphenol A-d16 were used as surrogates. Limits of quantification ranging from 0.1 to 0.6 ng mL−1 and interday variabilities (evaluated as relative standard deviations) from 2.0 to 13.8 % were obtained. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery rates ranged from 94 to 106 %. A good linearity, for concentrations up to 300 ng mL−1 for parabens and 40 ng mL−1 for benzophenones and bisphenols, was also obtained. The method was satisfactorily applied for the determination of target compounds in human urine samples from 20 randomly selected individuals.
引用
收藏
页码:3773 / 3785
页数:12
相关论文
共 50 条
  • [1] UHPLC-MS/MS method for the determination of bisphenol A and its chlorinated derivatives, bisphenol S, parabens, and benzophenones in human urine samples
    Vela-Soria, F.
    Ballesteros, O.
    Zafra-Gomez, A.
    Ballesteros, L.
    Navalon, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (15) : 3773 - 3785
  • [2] Simultaneous determination of bisphenol A and its chlorinated derivatives in human plasma: Development, validation and application of a UHPLC-MS/MS method
    Cambien, Guillaume
    Venisse, Nicolas
    Migeot, Virginie
    Rabouan, Sylvie
    Belmouaz, Mohamed
    Binson, Guillaume
    Albouy-Llaty, Marion
    Ayraud-Thevenot, Sarah
    Dupuis, Antoine
    CHEMOSPHERE, 2020, 242
  • [3] Reliable quantification of bisphenol A and its chlorinated derivatives in human urine using UPLC-MS/MS method
    Venisse, N.
    Grignon, C.
    Brunet, B.
    Thevenot, S.
    Bacle, A.
    Migeot, V.
    Dupuis, A.
    TALANTA, 2014, 125 : 284 - 292
  • [4] Ultrasensitive determination of bisphenol A and its chlorinated derivatives in urine using a high-throughput UPLC-MS/MS method
    Claire Grignon
    Nicolas Venisse
    Steeve Rouillon
    Bertrand Brunet
    Astrid Bacle
    Sarah Thevenot
    Virginie Migeot
    Antoine Dupuis
    Analytical and Bioanalytical Chemistry, 2016, 408 : 2255 - 2263
  • [5] Erratum to: Ultrasensitive determination of bisphenol A and its chlorinated derivatives in urine using a high-throughput UPLC-MS/MS method
    Claire Grignon
    Nicolas Venisse
    Steeve Rouillon
    Bertrand Brunet
    Astrid Bacle
    Sarah Thevenot
    Virginie Migeot
    Antoine Dupuis
    Analytical and Bioanalytical Chemistry, 2016, 408 : 2375 - 2375
  • [6] Development and validation of an LC-MS/MS method for the simultaneous determination of bisphenol A and its chlorinated derivatives in adipose tissue
    Venisse, Nicolas
    Cambien, Guillaume
    Robin, Julien
    Rouillon, Steeve
    Nadeau, Cedric
    Charles, Thomas
    Rabouan, Sylvie
    Migeot, Virginie
    Dupuis, Antoine
    TALANTA, 2019, 204 : 145 - 152
  • [7] Reliable quantification of bisphenol A and its chlorinated derivatives in human breast milk using UPLC-MS/MS method
    Cariot, Axelle
    Dupuis, Antoine
    Albouy-Llaty, Marion
    Legube, Bernard
    Rabouan, Sylvie
    Migeot, Virginie
    TALANTA, 2012, 100 : 175 - 182
  • [8] Ultrasensitive determination of bisphenol A and its chlorinated derivatives in urine using a high-throughput UPLC-MS/MS method (vol 408, pg 2255, 2016)
    Grignon, Claire
    Venisse, Nicolas
    Rouillon, Steeve
    Brunet, Bertrand
    Bacle, Astrid
    Thevenot, Sarah
    Migeot, Virginie
    Dupuis, Antoine
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (09) : 2375 - 2375
  • [9] New method for the determination of parabens and bisphenol A in human milk samples using ultrasound-assisted extraction and clean-up with dispersive sorbents prior to UHPLC-MS/MS analysis
    Rodriguez-Gomez, R.
    Dorival-Garcia, N.
    Zafra-Gomez, A.
    Camino-Sanchez, F. J.
    Ballesteros, O.
    Navalon, A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 992 : 47 - 55
  • [10] Rapid and sensitive determination of nine bisphenol analogues, three amphenicol antibiotics, and six phthalate metabolites in human urine samples using UHPLC-MS/MS
    Yuan Yao
    Yijun Shao
    Ming Zhan
    Xiaoli Zou
    Weidong Qu
    Ying Zhou
    Analytical and Bioanalytical Chemistry, 2018, 410 : 3871 - 3883